PubMed Health⌕ Search

Biomedical subjects

C J Page

Publications and source records attributed to C J Page.

At least 19 recordsLinked to original sources

In vivo evaluation of 111In-DTPA-N-TIMP-2 in Kaposi sarcoma associated with HIV infection.

Matrix metalloproteinases are the major agents responsible for the degradation of extracellular matrix and are produced at high levels by transformed and tumour cells, where they participate in the metastatic process by allowing local invasion. They are also more active at sites of new normal growth and angiogenesis. In the early stages of Kaposi sarcoma (KS), in vitro studies have demonstrated that vascular invasion can be inhibited by inhibitors of matrix metalloproteinases. Imaging of visceral and cutaneous KS presents a problem and therefore the potential use of a labelled inhibitor of metalloproteinases, N-TIMP-2, with indium-111 was thought to present a possible imaging tool. The biokinetics, dosimetry and potential for imaging with 111In-DTPA-N-TIMP-2 were assessed in five patients with HIV infection and KS. Between 103.1 and 108.0 MBq of this agent was injected into each patient, and the dynamic uptake over the kidneys was assessed, whole body scans were performed and blood samples were obtained. The clearance from the blood was rapid, with a first component half-time of 16.6+/-3.4 min and a second component half-time of 9.68+/-2.68 h. Two out of five patients experienced minor shivering but one of these patients was generally unwell before the study. The last three patients had no such problems. The tracer distributed predominantly to the kidneys and did not localise in other tissues. No KS lesions were clearly identified. 111In-DTPA-N-TIMP-2 can be successfully prepared and administered to patients safely, with a biodistribution and dosimetry which would allow its use as an imaging tracer. It is unlikely to be of use for imaging KS, but may have a role in other tumours that produce matrix metalloproteinases.

Adult↗

Evaluating the Swirler nebulizer: a user's perspective.

The change from multi-use to single-use nebulizer systems could potentially result in greatly increased expense for aerosol ventilation imaging and a larger waste disposal problem. We have therefore investigated a new compact single-use nebulizer system, the Swirler (Amici), for ventilation lung imaging using 99Tcm-DTPA aerosol. Seventy-five patients requiring lung ventilation/perfusion imaging were studied. The ventilation imaging was assessed using three different fills: Group 1, 1000 MBq in 2 ml; Group 2, 1000 MBq in 4 ml; and Group 3, 2000 MBq in 4 ml. The nebulization times to give 1200 counts s-1 on the posterior ventilation image were similar for Groups 1 and 3 (mean 4 min) but slower for Group 2 (mean 6 min). Room contamination was very low when performed in a room with an extractor device. The mean room air contamination was 117.0 Bq l-1 min-1 for Group 1 amd 27.6 Bq l-1 min-1 for Group 2, comparable to previous nebulizers we have used. Dose rates measured at the surface of the lead shielded nebulizer were 6.8 microSv h-1 for 1000 MBq in 2 ml and 10.9 microSv h-1 for 2000 MBq in 4 ml. The mass median diameter (span) without the extension tubing was 1.39 microns (1.85) and with a small extension tube reduced to 1.11 microns (1.70). Qualitative and quantitative assessment of image quality showed good peripheral airways penetration of particles with no uninterpretable scans, comparable with other systems we have used. In practical terms, the device is much more compact than other systems and therefore generates a much smaller volume of waste. It is an easy device to use. However, when ventilating patients supine or erect, we found that it was necessary to use the small extension tube.

Aerosols↗

Disposition of intravenous 123iodopentamidine in man.

This study compared the disposition of the radiopharmaceutical [123I]iodopentamidine with that of pentamidine after intravenous infusion by measuring plasma concentrations of each using scintilation counting and high-performance liquid chromatography (HPLC), respectively. There was rapid hepatic uptake and biliary excretion of the 123I label. Distribution kinetics of the 123I label were similar to those of pentamidine, but its elimination half-life (41 +/- 27 h) was longer than that of pentamidine measured by HPLC (11 +/- 8 h). [123I]iodopentamidine distribution reflects that of pentamidine, but elimination of the radiopharmaceutical appears slower.

Adult↗

Radioactively labelled diethylene triamine penta acetate lung scan in Pneumocystis carinii pneumonia and asymptomatic HIV-positive patients.

The objective of this study is to establish normal ranges for the assessment of lung permeability, using 99mTc DTPA (diethylene triamine penta acetate) aerosol by measuring the half-time of transfer from the lung in asymptomatic HIV-positive patients. Also to audit the use of the test in the clinical management of outpatients with symptoms suggestive of Pneumocystis carinii pneumonia (PCP). A retrospective analysis of data from outpatients' notes for the audit of symptomatic patients, and prospective acquisition of 'normal' data for HIV-positive asymptomatic patients who were non-smokers and smokers was performed. Over a period of 8 years, DTPA scans were performed on 400 asymptomatic HIV-positive patients (121 non-smokers and 279 smokers) and 188 symptomatic HIV-positive patients with symptoms suggestive of PCP. A biphasic curve of transfer of 99mTc DTPA with a half-time of less than 4 min, was considered diagnostic of PCP. The mean half-times (+/-SEM) for asymptomatic non-smokers was 61.4 +/- 3 min and for smokers was 21.9 +/- 0.8 min. In the symptomatic patients, 106 were treated for PCP and in 97 (91.5%) of these, the transfer was biphasic. Of the remaining 82 patients with respiratory pathology other than PCP, 71 (86.6%) had normal scans. The results show that smokers may have abnormal baseline scans 16/ 279 (5.7%) and therefore a baseline scan before symptoms should be recorded or a higher false positive rate can be expected. The test is however highly sensitive for the detection of PCP and allows the attending physician to initiate PCP treatment without delay.

AIDS-Related Opportunistic Infections↗

Comparison of jet and ultrasonic nebulizer pulmonary aerosol deposition during mechanical ventilation.

Increased delivery of aerosol to a model lung (attached to a mechanical ventilator) has been demonstrated with an ultrasonic nebulizer as compared to a jet nebulizer. This study examined whether the increased aerosol deposition with an ultrasonic nebulizer could also be demonstrated in vivo. Seven patients (6 male and 1 female) were studied during mechanical ventilalion (Siemens Servo 900C, Middlesex, UK) after open heart surgery. Two studies were performed in each patient. In the first study, aerosol was delivered via a Siemens Servo 945 nebulizer system (high setting) driving a System 22 Acorn jet nebulizer (Medic-Aid, Sussex, UK) containing 3 mL (99m)technetium-labelled human serum albumin (99mTc-HSA) (50 microg; activity 74 MBq). In the second study, a DP100 ultrasonic nebulizer (DP Medical, Meylan, France) containing 12 mL 99mTc-HSA (50 microg; activity 185 MBq) was used. Pulmonary deposition was quantified using a gamma camera. The humidification of the circuit and the ventilator settings were kept constant according to the patient's clinical requirements. The total lung aerosol deposition (mean+/-SD), as a percentage of initial nebulizer activity, was greater using the ultrasonic nebulizer than using the jet nebulizer (53+/-1.4 vs 2.3+/-0.9%; p<0.002). The ultrasonic nebulizer was also associated with a reduction in the time required to complete nebulization (9 vs 21 min, respectively) (p<0.0001). Use of the DP100 ultrasonic nebulizer more than doubled lung deposition compared with the System 22 jet nebulizers in mechanically-ventilated patients. Their efficiency, speed of drug delivery, and compatibility with mechanical ventilator circuits make ultrasonic nebulizers potentially attractive for use during mechanical ventilation.

Administration, Inhalation↗

Ventilation and perfusion lung imaging--which nebulizer?

Three commercially available 99Tcm-diethylenetriamine pentaacetate (99Tcm-DTPA) aerosol delivery nebulizers for lung ventilation imaging were investigated. Two were air-jet systems, 'Optimist' (Medicaid) and 'Microcirrus' (Amersham), and one was an ultrasonic device (Europlus). Altogether, 112 consecutive patients were scanned, 37 using the Optimist, 40 using the Microcirrus and 35 the Europlus. The age mix, FEV1, FVC and PEFR measurements of the patients in each group were similar. Each contained a proportion of patients with poor respiratory function, with PEFR rates ranging from 30 to 582 l min-1 for patients studied with all systems. Ease of use, image quality and cost were evaluated as well as radioactive and microbiological contamination. The Optimist system gave the best combination of image quality and cost, and was associated with the lowest level of radioactive contamination. It also proved the most popular. Airborne contamination for all nebulizers was lower than previously reported and was largely dependent on patient compliance. With poorly compliant patients, the contamination levels are sufficient to warrant an extraction device. There was no evidence of bacterial contamination of the nebulizers or tubing on repeated use over 5 days.

Forced Expiratory Volume↗

Effect of a spacer on pulmonary aerosol deposition from a jet nebuliser during mechanical ventilation.

BACKGROUND: Several factors have been identified which improve nebulised aerosol delivery in vitro. One of these is the addition of a spacer to the ventilator circuit which improves aerosol delivery from a jet nebuliser to a model lung by approximately 30%. The current study was designed to demonstrate whether similar improvements could be demonstrated in vivo. METHODS: Ten patients (seven men) were studied during mechanical ventilation (Siemens Servo 900C) after open heart surgery. Aerosol was delivered using a Siemens Servo 945 nebuliser system (high setting) driving a System 22 Acorn jet nebuliser (Medic-Aid) containing 3 ml technetium-99m labelled human serum albumin (99mTc-HSA (50 micrograms); activity in the first nebulisation, 90 MBq; in the second nebulisation, 185 MBq). Central and peripheral lung aerosol deposition and the time to complete deposition were measured using a gamma camera and compared when the nebuliser was connected to the inspiratory limb using a simple T-piece or a 600 ml spacer. RESULTS: The addition of the spacer increased total lung deposition (mean (SD) percentage initial nebuliser activity) from 2.2 (0.7)% to 3 (0.8)%. There was no difference in the time required to complete nebulisation (18.2 min v 18.3 min respectively for T-piece and spacer) or in the retention of activity in the nebuliser (46.2% v 47.1% respectively). CONCLUSIONS: The combination of a spacer with a jet nebuliser increased lung deposition by 36% in mechanically ventilated patients and is a simple way of increasing drug deposition or reducing the amount of an expensive drug required for nebulisation.

Aerosols↗

Regional sympathetic innervation of the heart by means of metaiodobenzylguanidine imaging in silent ischemia.

Metaiodobenzylguanidine was used to determine regional cardiac sympathetic innervation and whether it is reduced in silent ischemia. Patients with silent ischemia (group 1, n = 6) and angina (group 2, n = 5) and normal subjects (n = 6) underwent single-photon emission tomography at 4 hours. From base to midventricle, uptake increased in group 1 (p < 0.006), group 2 (p < 0.01), and the normal subjects (p < 0.004). In group 1 anterior ventricular uptake was greater than inferior uptake at the midventricle (p < 0.03) and apex (p < 0.05). In group 2 the same relationship was demonstrated at midventricle (p < 0.01) and apex (p < 0.05). Group 2 uptake was only significantly greater than group 1 at midventricle (p < 0.05). Innervation is greatest in midventricle and the apex of the left ventricle and greater in the anterior wall compared with the inferior wall. There is no evidence of reduced innervation in silent ischemia.

3-Iodobenzylguanidine↗

Disposition of nebulized pentamidine measured using the direct radiolabel 123I-iodopentamidine.

The pulmonary deposition of nebulized pentamidine (300 mg, Respirgard II nebulizer) was measured in seven human immunodeficiency virus (HIV)-positive men using a new radiopharmaceutical, 123I-iodopentamidine. Mean total pulmonary deposition was 15.3 mg or 5.1% of the initial nebulizer dose. Further studies in two of the patients showed that at 24 h, 87% of deposited 123I was retained in the lungs. Small amounts of activity (expressed as a percentage of the initial nebulizer activity) were also detected over the thyroid (0.4%), bladder (1%) and gut (0.7%). The ratio of 123I activity to pentamidine concentration was similar in the nebulizer solution and urine. These results suggest that 123I-pentamidine may be sufficiently stable in vivo to be used to study the biodistribution of inhaled and parenteral pentamidine in humans.

Administration, Inhalation↗

Pulmonary deposition of a nebulised aerosol during mechanical ventilation.

BACKGROUND: There is increasing use of therapeutic aerosols in patients undergoing mechanical ventilation. Few studies have measured aerosol delivery to the lungs under these conditions with adequate experimental methods. Hence this study was performed to measure pulmonary aerosol deposition and to determine the reproducibility of the method of measurement during mechanical ventilation. METHODS: Nine male patients were studied during mechanical ventilation after open heart surgery and two experiments were performed in each to determine the reproducibility of the method. A solution of technetium-99m labelled human serum albumin (99mTc HSA (50 micrograms); activity in experiment 1, 74 MBq; in experiment 2, 185 MBq) in 3 ml saline was administered with a Siemens Servo 945 nebuliser system (high setting) and a System 22 Acorn nebuliser unit. Pulmonary deposition was quantified by means of a gamma camera and corrections derived from lung phantom studies. RESULTS: Pulmonary aerosol deposition was completed in 22 (SD 4) minutes. Total pulmonary deposition (% nebuliser dose (SD)) was 2.2 (0.8)% with 1.5% and 0.7% depositing in the right and left lungs respectively; 0.9% of the nebuliser activity was detected in the endotracheal tube or trachea and 51% was retained within the nebuliser unit. Considerable variability between subjects was found for total deposition (coefficient of variation (CV) 46%), but within subject reproducibility was good (CV 15%). CONCLUSIONS: Administration of aerosol in this way is inefficient and further research is needed to find more effective alternatives in patients who require mechanical respiratory support. This method of measurement seems suitable for the assessment of new methods of aerosol delivery in these patients.

Administration, Inhalation↗

Lung deposition of nebulised pentamidine in children.

BACKGROUND: Nebulised pentamidine is effective for preventing Pneumocystis carinii pneumonia in adults with acquired immunodeficiency syndrome. The nebuliser dose required to produce equivalent lung concentrations of pentamidine in children is unknown. This study was performed to measure pulmonary pentamidine deposition in children and to relate this to age, ventilation pattern, and body size. METHODS: Nebulised pentamidine (50 mg in 6 ml saline) was administered to 12 children (including one with lymphocytic interstitial pneumonitis) and to six adults with human immunodeficiency virus infection using a Respirgard II nebuliser. Technetium-99m labeled colloidal human serum albumin was used as an indirect marker for pentamidine and deposition in the lungs was detected by a gamma camera. RESULTS: Absolute deposition of pentamidine was not related to age, height, weight, spirometry, or ventilation characteristics. Deposition, as a mean (SD) percentage of nebuliser output, was similar in children aged 8-11 years (5.5(2.4)%), teenagers aged 12-15 years (7.2(2.2)%) and adults (7.1(2.6)%). Aerosol concentration within the lungs (% nebuliser output deposited/predicted total lung capacity) was therefore higher in children (1.9(1.5)%/1) and teenagers (1.9(0.7)%/1) than in adults (1.0(0.7%)/1), and was negatively correlated with height (r = -0.69) and weight (r = -0.50). Deposition of aerosol in the region of the large central airways was particularly marked in children. Small reductions in forced expiratory volume in one second and forced vital capacity after treatment did not differ significantly between adults and children and visual analogue scores of subjective adverse effects did not vary with age. CONCLUSIONS: These results suggest that children probably require lower nebuliser pentamidine doses to produce lung pentamidine concentrations equivalent to those found to be effective for preventing P carinii pneumonia in adults using the Respirgard II nebuliser.

Acquired Immunodeficiency Syndrome↗

Delivery of ultrasonic nebulized aerosols to a lung model during mechanical ventilation.

Ultrasonic nebulizers may be particularly suitable for the administration of therapeutic aerosols to patients undergoing mechanical ventilation, but the amount of aerosol that reaches the patients' respiratory tract during ultrasonic nebulization has not been adequately studied. The delivery through an endotracheal tube of nebulized aerosols labeled with 99mTechnetium human serum albumin was therefore measured for five commercially available ultrasonic nebulizers using an in vitro model representing mechanical ventilation of an adult patient. Delivery of aerosol through the endotracheal tube ranged from 3.1 +/- 0.3% for Samsonic to 10.1 +/- 2.0% for Portasonic using 3 ml nebulizer solution. Increasing the volume of nebulizer solution to 18 ml (not possible for the Portasonic) increased delivery to 11.5 +/- 2.0 for the DP 100, 8.7 +/- 3.1 for Ultraneb, and 15.9 +/- 1.8% for Samsonic. Addition of a 600 ml aerosol storage chamber to the ventilator circuit increased delivery for the Samsonic (18 ml solution) to 22.3 +/- 5.0%. Aerosol delivery was also increased by reducing the respiratory rate and minute volume and by increasing the inspiratory time settings on the ventilator. These results confirm the potential value of ultrasonic nebulizers during mechanical ventilation and indicate that clinical trials in ventilated patients are warranted.

Adult↗

Delivery of a nebulized aerosol to a lung model during mechanical ventilation. Effect of ventilator settings and nebulizer type, position, and volume of fill.

Several factors may affect the delivery of a nebulized aerosol to the lung through an endotracheal tube during mechanical ventilation. To study these factors in vitro, a model representing ventilation of an adult patient was constructed by linking a Servo 900C ventilator to a standard humidified circuit and an endotracheal (ET) tube positioned within a pipe representing the trachea. This was connected via a filter to a lung simulator. Nebulizers filled with 99mTc human serum albumin were positioned in the circuit, and the delivery of nebulized aerosol through the ET tube into the filter was measured using a gamma camera. With the use of an inspiratory phase-activated System 22 Acorn jet nebulizer, typical adult ventilator settings, and a 3-ml nebulizer solution volume, 5.4% of the nebulizer dose reached beyond the end of the ET tube. This was increased by increasing the inspiratory time, reducing the respiratory rate or respiratory minute volume, and by repositioning the nebulizer on the inspiratory limb of the Y-piece and was reduced by slowing the driving gas flow to the nebulizer. Under the same conditions, delivery was 3.1 and 4.4% using the Samsonic and Fisoneb ultrasonic nebulizers, respectively. Increasing the fill volume and the addition of an aerosol storage chamber increased delivery with all three nebulizers. These experiments suggest some simple ways of improving aerosol delivery during mechanical ventilation, including increasing the volume of nebulizer fill, repositioning the nebulizer in the ventilator circuit, adding an aerosol storage chamber, and adjusting ventilator settings to maximize delivery.

Adult↗

Variability in the measurement of nebulized aerosol deposition in man.

1. This study was performed to determine the variability of two different scintigraphic methods of measuring pulmonary aerosol deposition, and to examine nebulizer particle size and drug output as potential sources of this variability. 2. A radioaerosol was produced from a 3 ml solution of 99mTc-labelled colloidal human serum albumin (0.05 mg, 37 MBq) using a standard jet nebulizer and air compressor. This was inhaled on three separate occasions by nine healthy male subjects. One one of these occasions, a further inhalation was performed to assess immediate repeatability using increased 99mTc activity (92 MBq). 3. Intrapulmonary aerosol deposition was measured with a gamma-camera and was corrected for tissue attenuation and geometric distribution by using two different methods. 4. Estimated mean pulmonary deposition was 4.3% of the nebulizer dose using a lung phantom correction method, and 6.1% using a tissue attenuation method. For these two methods respectively variability between subjects (coefficient of variation) was 54 and 47%. For both methods, within-subject variability (coefficient of variation) was 37% between occasions and 23% within occasions. 5. The particle-size output of several nebulizers was highly reproducible (coefficient of variation less than 4%), but the nebulizer mass and radionuclide output of two nebulizers was more variable (coefficient of variation 5-19%), and appeared to be an important contributor to the variability in pulmonary aerosol deposition. 6. The data presented here for pulmonary deposition, used with appropriate power statistics formulae, can be used to estimate the sample sizes required for comparative studies of lung aerosol deposition.

Aerosols↗

Pulmonary deposition of nebulised amiloride in cystic fibrosis: comparison of two nebulisers.

BACKGROUND Preliminary evidence suggests that regular inhalation of nebulised amiloride reduces sputum viscoelasticity, increases the clearance of sputum by mucociliary mechanisms and by coughing and reduces the rate of deterioration in lung function in patients with cystic fibrosis. These effects depend on adequate delivery of amiloride to the airways. This study was performed to quantify and compare pulmonary deposition of amiloride produced by two different nebuliser systems. METHODS The pulmonary deposition of nebulised amiloride (1 mg in 3 ml saline) was measured in eight patients with cystic fibrosis when given via a jet (System 22 with CR 60 compressor) and an ultrasonic (Fisoneb) nebuliser. Human serum albumin labelled with technectium-99m was used as an indirect marker for amiloride and its deposition in the lung was detected with a gamma camera. RESULTS Amiloride inhalation caused no side effects or changes in spirometric indices. The mean (SD) total pulmonary amiloride deposition was 57 (24) micrograms with the System 22 and 103 (53) micrograms with the Fisoneb nebuliser. Pulmonary deposition was completed more rapidly with the Fisoneb (4-5 minutes) than with the System 22 nebuliser (7-8 minutes) and the Fisoneb was preferred by the patients. CONCLUSIONS Both nebulisers appeared to deliver adequate amounts of amiloride to the lungs, but treatment with the Fisoneb nebuliser was quicker, more efficient, and more acceptable to the patients. Of the two nebulisers assessed, the Fisoneb would be preferred for clinical trials.

Administration, Inhalation↗