PubMed Health⌕ Search

Biomedical subjects

C J Pendegrass

Publications and source records attributed to C J Pendegrass.

5 recordsLinked to original sources

Nature's answer to breaching the skin barrier: an innovative development for amputees.

The human body has evolved to maintain homeostasis through the covering of skin and mucous membranes, which separate the internal environment from the harsh and variable external milieu. Few structures naturally penetrate these coverings, and teeth are the only exception in human beings. Attempts to breach these barriers, to develop skin- penetrating, bone-anchored amputation prostheses, can lead to opportunist invasion by microorganisms and subsequent infection, which can jeopardize the life of the individual. There are only a few fascinating examples where the integument of other species is interrupted without such dire consequences, and the deer antler is one such case. Deer antlers are cephalic bony appendages arising from the frontal bones of the skull of the males of most deer species, and are true transient skin-penetrating structures. Antlers are subject to extreme loading during the rutting season and yet the skin-bone barrier remains intact. Here we show how deer antlers can be used as natural analogues for the successful development of specialized orthopaedic amputation prosthetics. We have used quantitative and qualitative findings from a study of the morphology of deer antlers to develop a device that mimics their structure, which creates a tight seal between the implant and the host tissues, for use in amputation prosthetics.

Amputation, Surgical↗

Assessment of reproducibility and accuracy in templating hybrid total hip arthroplasty using digital radiographs.

In 20 patients undergoing hybrid total hip arthroplasty, the reproducibility and accuracy of templating using digital radiographs were assessed. Digital images were manipulated using either a ten-pence coin as a marker to scale for magnification, or two digital-line methods using computer software. On-screen images were templated with standard acetate templates and compared with templating performed on hard-copy digital prints. The digital-line methods were the least reliable and accuracy of sizing compared with the inserted prostheses varied between -1.6% and +10.2%. The hard-copy radiographs showed better reproducibility than the ten-pence coin method, but were less accurate with 3.7% undersizing. The ten-pence coin method was the most accurate, with no significant differences for offset or acetabulum, and undersizing of only 0.9%. On-screen templating of digital radiographs with standard acetate templates is accurate and reproducible if a radiopaque marker such as a ten-pence coin is included when the original radiograph is taken.

Acetabulum↗

The novel use of resorbable Vicryl mesh for in vivo tendon reconstruction to a metal prosthesis.

We examined the mechanical properties of Vicryl (polyglactin 910) mesh in vitro and assessed its use in vivo as a novel biomaterial to attach tendon to a hydroxyapatite-coated metal implant, the interface of which was augmented with autogenous bone and marrow graft. This was compared with tendon re-attachment using a compressive clamp device in an identical animal model. Two- and four-ply sleeves of Vicryl mesh tested to failure under tension reached 5.13% and 28.35% of the normal ovine patellar tendon, respectively. Four-ply sleeves supported gait in an ovine model with 67.05% weight-bearing through the operated limb at 12 weeks, without evidence of mechanical failure. Mesh fibres were visible at six weeks but had been completely resorbed by 12 weeks, with no evidence of chronic inflammation. The tendon-implant neoenthesis was predominantly an indirect type, with tendon attached to the bone-hydroxyapatite surface by perforating collagen fibres.

Animals↗

Extensor mechanism reconstruction after proximal tibial replacement.

We developed an in vivo model of the attachment of a patellar tendon to a metal implant to simulate the reconstruction of an extensor mechanism after replacement of the proximal tibia. In 24 ewes, the patellar tendon was attached to a hydroxyapatite (HA)-coated titanium prosthesis. In 12, the interface was augmented with autograft containing cancellous bone and marrow. In the remaining ewes, the interface was not grafted. Kinematic gait analysis showed nearly normal function of the joint by 12 weeks. Force-plate assessment showed a significant increase in functional weight-bearing in the grafted animals (p = 0.043). The tendon-implant interface showed that without graft, encapsulation of fibrous tissue occurred. With autograft, a developing tendon-bone-HA-implant interface was observed at six weeks and by 12 weeks a layered tendon-fibrocartilage-bone interface was seen which was similar to a direct-type enthesis. With stable mechanical fixation, an appropriate bioactive surface and biological augmentation the development of a functional tendon-implant interface can be achieved.

Animals↗

A histomorphological study of tendon reconstruction to a hydroxyapatite-coated implant: regeneration of a neo-enthesis in vivo.

The attachment of tendons and ligaments to massive endoprostheses remains a clinical challenge due to the difficulty in achieving a soft tissue implant interface with a mechanical strength sufficient to transmit the forces necessary for locomotion. We have used an in vivo animal model to study patellar tendon attachment to an implant surface. The interface generated when the patellar tendon was attached to a hydroxyapatite (HA) coated implant was examined using light microscopy and a quantitative histomorphological analysis was performed. In the Autograft Group, the interface was augmented with autogenous cancellous bone and marrow graft, and at six weeks an indirect-like insertion was observed. At twelve weeks, the interface was observed to be a layered neo-enthesis, whose morphology was similar to a normal direct tendon insertion. In the HA Group, the tendon-implant interface was not augmented, and the implant was enveloped by a dense collagenous fibrous tissue. This study shows that a tendon-implant neo-enthesis can develop in situ by employing a suitable implant surface in association with biological augmentation.

Animals↗