Evaluation of electron beam CT coronary angiography in healthy subjects.

OBJECTIVE: This study evaluated the performance characteristics of electrocardiographically triggered, contrast-enhanced electron beam CT (EBCT) in defining the coronary artery lumen in healthy subjects. SUBJECTS AND METHODS: The coronary arteries of 11 healthy young men (mean age, 24 years old) were evaluated by contrast-enhanced EBCT. Measured parameters included degree of luminal enhancement, intravascular contrast-to-noise ratio, apparent luminal diameter, and length of continuously visualized lumen (100-H threshold for diameter and length measurements). RESULTS: Aortic blood pool attenuation was 44 +/- 5 H (mean +/- SD) before and 278 +/- 35 H after IV injection of contrast material. Contrast-to-noise ratios ranged from a high of 10.0 +/- 2.6 in the proximal right coronary artery to a low of 3.2 +/- 2.7 in the distal left circumflex artery, decreasing from proximal to distal within each vessel. Apparent luminal diameters were as follows: left main coronary artery, 4.5 +/- 0.6 mm; left anterior descending artery, 3.7 +/- 0.5 mm; left circumflex artery, 2.9 +/- 0.6 mm; and right coronary artery, 3.5 +/- 0.5 mm. The mean lengths of visualized lumina were as follows: left main coronary artery, 10 +/- 4 mm; left anterior descending artery, 65 +/- 26 mm; left circumflex artery, 45 +/- 20 mm; and right coronary artery, 58 +/- 24 mm. CONCLUSION: EBCT angiography can reveal the lumen of long segments of the major coronary arteries.

Adult↗

Three-dimensional ultrasonic angiography using power-mode Doppler.

To visualize the vascular anatomy of parenchymal organs, we have developed a system for producing three-dimensional ultrasonic angiograms (3D USA) from a series of two-dimensional power-mode Doppler ultrasound (PDU) scans. PDU scans were acquired using a commercial scanner and image-registration hardware. Two-dimensional images were digitized, and specially designed software reconstructed 3D volumes and displayed volume-rendered images. The geometric accuracy of our system was assessed by scanning a flow phantom constructed from tubing. The system was tested on patients by scanning native and transplanted kidneys, and placentas. Three-dimensional images of the phantoms depicted the spatial relationships between flow within the tubing segments and contained less than 1 mm of geometric distortion. Three-dimensional images of the kidney and placenta demonstrated that spatial relationships between vasculature structures could be visualized with 3D USA. Applications of this new technique include analysis of vascular anatomy and the potential assessment of organ perfusion.

Angiography↗

Predictive respiratory gating: a new method to reduce motion artifacts on CT scans.

PURPOSE: To evaluate a gating system, called predictive respiratory gating (PRG), that reduces motion-induced artifacts on computed tomographic (CT) scans of patients who cannot suspend respiration. MATERIALS AND METHODS: PRG uses a respiration monitor and a new algorithm to predict when a motionless period is about to occur. It automatically starts scanning so the scan is temporally centered around the motionless period at end inspiration or end expiration. To demonstrate PRG, CT was performed on a motion phantom and a quietly breathing volunteer with and without gating. RESULTS: Scans of the phantom obtained with PRG contained less motion-induced streaking and blurring than did scans acquired without PRG. Scans of the volunteer gated at end expiration contained significantly less artifact than nongated scans (P < .03). CONCLUSION: PRG reduced motion artifact on scans of a spontaneously breathing volunteer. PRG may be able to reduce motion artifacts on scans of patients unable to suspend respiration.

Adult↗

Minimum scan speeds for suppression of motion artifacts in CT.

Cardiac and ventilatory motions cause artifacts at chest computed tomography (CT). To determine how short the scan times on third-generation units must be to avoid such artifacts, motion was measured with fast and ultrafast CT scans. Minimum detectable motion was then determined. The longest scan time that avoided a barely perceptible artifact was calculated by dividing the minimum detectable motion by the peak physiologic velocity. The posterior left ventricular wall moved at a maximum velocity of 52.5 mm/sec, necessitating a scan time of 19.1 msec or less to avoid artifact. Lung vessels near the heart moved at 40.5 mm/sec for a scan time of 24.7 msec or less. During quiet breathing, pulmonary vessels moved at 10.7 mm/sec for a scan time of 93.5 msec or less. The authors conclude that the shortest scan time on third-generation units (0.6 second) cannot prevent all artifacts arising from motion in the chest. Even ultrafast scan times (50 msec) are not short enough to eliminate artifacts on these units. Thus, reduction of motion artifacts will require techniques other than fast scanning.

Artifacts↗