PubMed Health⌕ Search

Biomedical subjects

C J Siepe

Publications and source records attributed to C J Siepe.

3 recordsLinked to original sources

[Replacement of the anterior cruciate ligament. Biomechanical studies for patellar and semitendinosus tendon fixation with a poly(D,L-lactide) interference screw].

Anterior cruciate ligament (ACL) reconstruction using autologous hamstring tendons are being performed more frequently and satisfactory results have been reported. Advantages such as low donor site morbidity and ease of harvest as well as disadvantages like low initial construct stiffness have been described. Recently, it has been demonstrated that graft fixation close to the original ACL insertion sites increases anterior knee stability and graft isometry. Hamstring tendon fixation techniques using interference screws offer this possibility. To reduce the risk of graft laceration, a round threaded titanium interference screw (RCI) was developed. To improve initial fixation strength, fixation techniques for hamstring tendons with separate or attached tibial bone plugs were introduced. However, data on fixation strength do not yet exist. With respect to the proposed advantages of biodegradable implants, like undistorted magnetic resonance imaging, uncompromised revision surgery and a decreased potential of graft laceration during screw insertion, we performed pullout tests of round threaded biodegradable and round threaded titanium interference screw fixation of semitendinosus (ST) grafts with and without distally attached tibial bone plugs. Data were compared with bone-tendon-bone (BTB) graft fixation using biodegradable and conventional titanium interference screws. We used 56 proximal calf tibiae to compare maximum pullout force, screw insertion torque, and stiffness of fixation for biodegradable direct ST tendon and bone plug fixation (group I: without bone plug, group II: with bone plug) versus titanium interference screw fixation (group III: without bone plug, group IV: with bone plug). A round threaded biodegradable poly-(D, L-lactide) (Sysorb) and a round threaded titanium interference screw (RCI) were used. As a control calf bone-tendon-bone (BTB) grafts fixed with either poly-(D, L-lactide) (group V) or conventional titanium (group VI) interference screws were used. ST tendons were harvested either with or without their distally attached tibial bone plugs from human cadavers and were folded to a three-stranded graft. Specimen were loaded in a material testing machine with the applied load parallel to the long axis of the bone tunnel. Maximum pullout force of ST bone plug (group III: 717 N +/- 90, group IV: 602 N +/- 117) fixation was significantly higher than that of direct tendon (group I: 507 N +/- 93, group III: 419 N +/- 77) fixation. Maximum pullout force of biodegradable screw ST fixation was higher than that of titanium screw fixation in both settings. There was no significant difference in pullout force between biodegradable (713 N +/- 210) and titanium (822 N +/- 130) BTB graft fixation or between ST fixation with bone plug and biodegradable screw with BTB fixation. Pullout force of hamstring tendon interference screw fixation can be improved by using a biodegradable implant. In addition, initial pullout force can be greatly improved by harvesting the hamstring tendon graft with its distally attached tibial bone plug. This may be important, especially in improving tibial graft fixation. This study encourages further research in tendon-bone healing with direct interference screw fixation to confirm the potential of this advanced method.

Anterior Cruciate Ligament↗

Hamstring tendon fixation using interference screws: a biomechanical study in calf tibial bone.

It has recently been shown that graft fixation close to the ACL insertion site is optimal in order to increase anterior knee stability. Hamstring tendon fixation using interference screws offers this possibility and a round threaded titanium interference screw has been previously developed. The use of a round threaded biodegradable interference screw may be equivalent. In addition, to increase initial fixation strength, graft harvest with a distally attached bone plug may be advantageous, but biomechanical data do not exist. This study compares the initial pullout force, stiffness of fixation, and failure modes of three strand semitendinosus grafts in 36 proximal calf tibiae using either biodegradable poly-(D,L-lactide) (Sysorb; Sulzer Orthopaedics Ltd, Münsingen, Switzerland) or round threaded titanium (RCI; Smith & Nephew DonJoy, Carlsbad, CA) interference screws, harvested either without (biodegradable: group I, titanium III) or with (biodegradable: group II, titanium: group IV) attached tibial bone plugs. Maximum pullout force in group I (507 +/- 93 N) was significantly higher than in group III (419 +/- 77 N). Pullout force of bone plug fixation was significantly higher than that of direct tendon fixation (717 +/- 90 N in group II and 602 +/- 117 N in group IV). Pullout force of biodegradable fixation was significantly higher in both settings. These results indicate that initial pullout force of hamstring-tendon graft interference screw fixation can be increased by using a biodegradable interference screw. In addition, initial pullout force of hamstring-tendon graft fixation with an interference screw can be greatly increased by harvesting the graft with its distally attached tibial bone plug.

Absorption↗

The influence of screw geometry on hamstring tendon interference fit fixation.

We used a standardized model of calf tibial bone to investigate the influence of screw diameter and length on interference fit fixation of a three-stranded semitendinosus tendon graft for anterior cruciate ligament reconstruction. Biodegradable poly-(L-lactide) interference screws with a diameter of 7, 8, and 9 mm and a length of 23 and 28 mm were used. We examined results in three groups of 10 specimens each: group 1, screw diameter equaled graft diameter and screw length was 23 mm; group 2, screw diameter equaled graft diameter plus 1 mm and screw length was 23 mm; group 3, screw diameter equaled graft diameter and screw length was 28 mm. The mean pull-out forces in groups 1, 2, and 3 were 367.2+/-78 N, 479.1+/-111.1 N, and 537.4+/-139.1 N, respectively. The force data from groups 2 and 3 were significantly higher than those from group 1. These results indicate that screw geometry has a significant influence on hamstring tendon interference fit fixation. Increasing screw length improves fixation strength more than oversizing the screw diameter. This is important, especially for increasing tibial fixation strength because the tibial graft fixation site has been considered to be the weak link of such a reconstruction.

Animals↗