Liquid-core waveguide technology for coupling column liquid chromatography and Raman spectroscopy.

The on-line coupling of liquid chromatography (LC) and Raman spectroscopy (RS) via an entirely plastic liquid-core waveguide (LCW) was optimized in terms of excitation wavelength of the laser, especially in relation to the fluorescence background, and the length of the LCW. Excitation at 632.8 nm (He-Ne laser) was found to be a good compromise between a wavelength long enough to strongly reduce the fluorescence background and, on the other hand, short enough to avoid (re)-absorption of laser light and Raman signals by H2O in LCWs of considerable length. This conclusion is supported by a theoretical discussion on the optimization of LCW lengths as function of the excitation wavelength for H2O and 2H2O. When using the He-Ne laser the optimum length is approximately 50 cm for H2O; this corresponds to a detection cell volume of 19 microl for an LCW of 220 microm I.D., which is fully compatible with conventional-size LC. The influence of an organic modifier, usually necessary for reversed-phase LC, on the free spectral window was evaluated. The potential applicability of LC-LCW-RS was shown for a mixture of adenosine 5'-monophosphate (AMP), guanosine 5'-monophosphate (GMP) and uridine 5'-monophosphate (UMP), utilizing an aqueous eluent without the addition of a modifier. Improved detectability was achieved by using the stopped-flow mode and applying a large-volume-injection procedure (injection volume: 200 microl). Under these conditions, the limit of identification for AMP, GMP and UMP was in the 0.1-0.5-mg/ml range.

Adenosine Monophosphate↗

Miniaturized automated matrix solid-phase dispersion extraction of pesticides in fruit followed by gas chromatographic-mass spectrometric analysis.

In this study a simple and fast miniaturized automated matrix solid-phase dispersion method for the sample preparation and quantitative extraction of pesticides was developed and evaluated. Only 25 mg of sample and 100 microl of organic solvent were used per analysis for this new miniaturized set-up. The extracts were subsequently analysed by GC-MS without any further purification. The method was optimized for oranges and tested for the determination of a variety of organophosphorus pesticides and a pyrethroid at concentration levels below the maximum residue levels set by the European Union and authorities in The Netherlands. The limits of detection were 4-90 microg/kg. The recoveries for pesticides in orange were 83-118% and the relative standard deviations for the total procedure were 10-13% (n=4) at the limit of quantification. The feasibility of the developed method for apple, pear and grapes was also studied. Equally good results were obtained, but for apple the washing step should be omitted.

Automation↗