Bone remodeling around cementless hip implants.

Bone remodeling results from the adaptation of bone to the stresses that act upon it. The insertion of an endoprosthesis into a femur changes the stress distribution within the femur, causing the bone to remodel. In this paper, we show how radiographic bone remodeling changes can be used to determine implant fixation and how bone remodeling changes can be quantitated by using dual-energy x-ray absorptiometry analysis as well as computer-assisted videodensitometry.

Absorptiometry, Photon↗

Wear of polyethylene cups in total hip arthroplasty. A study of specimens retrieved post mortem.

The wear of polyethylene components of total hip replacements has previously been studied radiographically and by analysis of retrieved components. The extent of wear, however, has largely been determined from components retrieved at reoperation and has therefore been based on a subset of patients in whom the prosthesis is more likely to show excessive wear. The study of cups retrieved post mortem provides a better indication of the extent of wear of well functioning components. Twenty-six polyethylene liners were retrieved at autopsy from nineteen patients, after a mean of ninety-one months (range, thirty-three to 206 months) in situ. Each component had articulated with a thirty-two-millimeter-diameter femoral head. The components were evaluated visually for evidence of polyethylene wear such as pitting, scratching, and burnishing. Additionally; a shadowgraph technique was used to examine molds of the inner surface of the liner to determine the direction and extent of wear. The mean extent of linear wear of the retrieved liners was 0.45 millimeter (range, 0.17 to 1.07 millimeters), and the mean rate of wear was 0.07 millimeter (range, 0.02 to 0.18 millimeter) per year. The mean volumetric wear was 245.3 cubic millimeters (range, 13.0 to 779.1 cubic millimeters), and the mean rate of volumetric wear was 39.8 cubic millimeters (range, 1.0 to 131.3 cubic millimeters) per year. The mean rate of wear for the twenty-six liners was 45 to 69 per cent less than the rates reported in the literature for polyethylene liners retrieved at reoperation. Examination of the articulating surface did not reveal gross evidence of surface failure such as delamination or fatigue cracks. In general, the surfaces were merely burnished and scratched. The rates of wear of press-fit, metal-backed liners were significantly higher than those of all-polyethylene cemented components (p < 0.05). Additionally, statistical analysis revealed no correlation between wear and the patient's age, weight, or gender; the duration of implantation; or the thickness of the polyethylene. These results indicate that wear of the polyethylene of well functioning hip replacements is not as excessive as reported previously.

Acetabulum↗

The influence of clinical factors on periprosthetic bone remodeling.

The femurs of 11 patients with well-functioning unilateral hip replacements were retrieved at autopsy and analyzed for periprosthetic bone remodeling by dual energy xray absorptiometry. Each case involved a femur with a porouscoated endoprosthesis; the endoprosthesis remained implanted for an average of 5.9 years. In the contralateral femur, a matching prosthesis was implanted in vitro, to serve as a control for comparisons. There was an average 22.6% decrease in bone mineral content in the in vivo implanted femur (range, 5.4%-47.4%). Females experienced an average bone loss of 31.2%, which was significantly higher than the 12.3% average loss in males. Longitudinal analysis revealed an average decrease in bone mineral content of 42.1% proximally, 23% in the midsection, and 5.5% distally. Percent decreases in total bone mineral content were correlated with the following clinical variables: weight, age, implant diameter, duration of implantation, and contralateral femoral bone mineral content. Only the bone mineral content of the contralateral femur had a strong predictive value. Bone loss was greater in femurs with low bone mineral content than in those with high bone mineral content. Weight, age, implant diameter, and duration of implantation were not correlated with bone loss.

Absorptiometry, Photon↗