The distally based posterior tibial arterial adipofascial flap.

A distally based posterior tibial artery adipofascial flap with skin graft was used for the reconstruction of soft tissue defects over the Achilles tendon in three cases and over the heel in three cases. Good resurfacing with protective sensation of these wounds was achieved. There was no breakdown of the graft or morbidity of donor sites, which were closed primarily. We believe there were many advantages to this adipofascial flap and that it is an ideal choice for the reconstruction of soft tissue defects in the lower third of the leg and foot, especially over the Achilles tendon.

Achilles Tendon↗

A versatile method for reconstruction of finger defects: reverse digital artery flap.

Four types of the reverse digital artery flap--standard, extended, and innervated standard and extended--were developed for 52 finger defects. The arising pattern of the dorsal branch which was included in the innervated flap was studied and classified in cadaver dissections. Topographically, the described "Lai's line" is a useful guide to locate the underlying digital artery. Refinements in flap design and surgical technique resulted in favourable functional and cosmetic results. The average two-point discrimination of the reconstructed fingertip was 6.8 mm and 3.9 mm in the noninnervated and innervated flaps, respectively. This versatile flap is an ideal and reliable option for one-stage reconstruction of various finger defects.

Adolescent↗

Thermographically determined specific absorption rate patterns of 434-MHz applicators.

The specific absorption rate (SAR) patterns of two 434-MHz hyperthermia applicators, models TCA 434-1 (9 X 20 cm) and TCA 434-2 (13 X 25 cm), were evaluated thermographically using a phantom model. The phantom model consisted of a 2-cm-thick layer of fat and a 10-cm depth of muscle contained in a 30 X 30 cm base Plexiglas box. The model was bisected in the middle. Polyester screens at the interface allowed the synthetic gel to make electrical contact between the two halves of the muscle tissue. Octyl alcohol was applied to the fat interface to ensure continuity of dielectric properties. Thermograms were taken for both applicators over the following areas of the exposed model: (1) fat surface, (2) internal surface with E-field parallel to interface, and (3) internal surface with E-field perpendicular to interface. SAR's were calculated from the temperature rise (8 degrees C maximum), net input power (550-650 W), exposure time (15-60 s), and specific heat of the muscle (0.86 kcal/kg degrees C). A factor of 0.42 needs to be multiplied to correct for the specific heat of fat. High localized SAR's along the broad sides of the applicators were seen when the applicators were in direct contact with the phantom. With the use of a 0.8-cm polystyrene foam spacing, the SAR's within the aperture of the applicators were relatively uniform. The patterns of the two applicators were quite similar. However, the TCA 434-1 applicator is smaller and more applicable for clinical conditions.

Absorption↗

Evaluation of captive bolus applicators.

Three square (L, M, MS) and one rectangular (HN) applicators with captive boluses were provided by the Clini-Therm Corporation for evaluation. Surface cooling is achieved by attaching a mineral oil captive bolus to the built in water-circulating tubes at the aperture of the applicators. These applicators were tested on a phantom with a 2-cm fat slab over 10-cm-thick muscle. Surface and sagittal heating patterns were obtained using a thermograph. All captive-bolus applicators have heating patterns similar to that of the regular Clini-Therm applicators. Due to hot spots at the edges of the applicators where the E fields terminate, these modified applicators should not be placed in direct contact with patients when boluses are not used. Tests with Clini-Therm regular water bolus instead of the captive oil bolus indicated that the orientation of water flow should be parallel to the E field to minimize perturbation of the heating patterns. Thermal conduction studies showed that the captive bolus reacts too slowly for skin temperature control. The modified captive bolus applicators did not improve the performance of the system.

Adipose Tissue↗

Heating patterns of microwave applicators in inhomogeneous arm and thigh phantoms.

Heating rate (HR) patterns in cylindrical structures were studied with inhomogeneous limb phantoms. These phantoms, arm and thigh models consisting of fat, bone, and muscle material, were heated with Clini-Therm L, M, and MS applicators at 915 MHz. The thigh model is 18 cm in diameter with 2.65-cm-thick fat on the outside and a 4-cm-diam bone in the center. The arm model is 9 cm in diameter with 1.35-cm-thick fat and 2-cm-diam bone. All models are 29 cm long with phantom muscle in the space between fat and bone and were heated with their long axes parallel or perpendicular to the E field. HR patterns in the transverse and longitudinal planes were obtained thermographically. A large water bolus, with the water channels parallel to the E field, was used in every case. In the thigh model, maximum heating was in the muscle for both L and M applicators when the E field was parallel to the long axis. When it was perpendicular, the maximum heating occurred in the fat layer. However, the peak HR in the fat remained about the same for both E field orientations. For the small applicator, heating was mostly in the fat, and the two field orientations did not cause much difference in the heating pattern. In the arm model, the maximum heating of all three applicators occurred mostly in the muscle for both E-field orientations. However, the maximum HR was reduced by a factor of 2 to 3 when the E field was perpendicular rather than parallel to the long axis.(ABSTRACT TRUNCATED AT 250 WORDS)

Arm↗

Elevated nitric oxide level in aqueous humor of patients with acute angle-closure glaucoma.

Nitric oxide, a noxious and free-radical gas, plays a key role in vasodilatation, inflammation, immunity, and neurotoxicity. Studies have shown that a recently detected NO synthase inducible isoform, found in astrocytes in the optic nerve heads of glaucoma patients, could stimulate excessive production of NO. The purpose of our study was to elucidate the role of NO production in the pathogenesis of glaucoma. We measured the concentrations of NO in aqueous humor from 11 patients with acute angle-closure glaucoma (AACG) and 14 patients with cataract. All samples were collected from patients who were free of any other systemic disease. Utilizing a chemiluminescence assay, we found that in AACG patients the NO levels in aqueous humor samples (83.2 +/- 6.7 microM) were significantly higher than in cataract patients (27.1 +/- 3.6 microM; p < 0.001). We therefore concluded that excessive NO in AACG patients reflects the degree of ocular impairment demonstrated by concomitant retinal cell and optic nerve cell damage.

Acute Disease↗

Perturbations due to the use of catheters with non-perturbing thermometry probes.

Perturbations due to the use of catheters with non-perturbing thermometry probes were investigated in static phantom at 915 MHz. Fibre optic probes for the Luxtron and Clini-Therm thermometry systems, and Vitek probes for the BSD hyperthermia systems, were inserted in closed-end catheters at depths up to 2 cm in the phantom and exposed parallel to the E-field. The probes alone produced 0-12 per cent changes in heating and catheters alone were 0-20 per cent. When the probes were inserted in catheters, perturbations were 0-12 per cent at the surface and 1 cm depth, and 5-15 per cent at 2 cm depth. Even with non-perturbing probes it is important to place catheters perpendicular to the E-field during microwave hyperthermia.

Electromagnetic Fields↗

Changes in heating patterns due to perturbations by thermometer probes at 915 and 434 MHz.

The changes in heating patterns due to perturbations by thermometer probes in microwave fields were investigated in static phantoms at 915 and 434 MHz. Thermograms taken parallel to the plane of E and H fields, at depths of up to 2 cm, indicated heating changes of +25 to -45 per cent at 915 MHz and +/- 15 per cent at 434 MHz. The amount of perturbation is dependent on the length, size and location of the probes in the RF fields and their orientations to the electric field. If proper probe placement techniques are not observed when metallic probes are involved, hot and cool spots can be generated and shifted to sites that are not measured. Therefore misleading temperatures can result when changes in heating patterns are not detected. Perturbation also varies with applicator designs and phantom geometry. If thermistors and thermocouples are used, the effects of perturbation should be investigated with individual applicators under applicable clinical conditions.

Hyperthermia, Induced↗

Changes in heating patterns of interstitial microwave antenna arrays at different insertion depths.

The changes in heating patterns of interstitial microwave antennas at different insertion depths were investigated in a static phantom at 915 MHz. Antennas for the Clini-Therm Mark VI system were inserted 5-15 cm into muscle-equivalent material, through nylon catheters. The phantom was heated with arrays of antennas at 2 cm spacings for 60 s at 15 W per antenna. Midplane and transverse heating patterns were determined thermographically with the antennas inserted parallel or perpendicular to the split of the phantom. Hot spots, independent of heating near the junction plane, were observed in the midplane of the 2 x 2 and 2 x 4 arrays at 2.8 cm from the insertion end. The magnitudes of these hot spots were reduced by 40-45 per cent as insertion depth was increased from 7 to 10.5 cm. With insertion depths of more than 11.5 cm the hot spots gradually diminished and heating occurred mostly near the junction plane. The observed heating patterns were caused by changes in impedance of the antenna arrays at different insertion depths. The impedance mismatch had resulted in different wave propagation within the tissue material which produced different radiation patterns. During treatments, because heating varies with insertion depth, great care must be exercised in monitoring temperatures.

Biomedical Engineering↗

Intracavitary hyperthermia applicators for treating nasopharyngeal and cervical cancers.

Many intracavitary microwave applicators have been designed to heat tissues along the side of an antenna. For tumours in nearly closed-end cavities such as the nasopharynx and cervix, heating near the tip of the applicators is necessary for effective treatment. A nasopharyngeal applicator made of Micro Coax UT-250A and a cervical applicator made of RG-9/U cables were designed to provide heating at the tip. Return losses of 8-12 dB were obtained at 915 MHz by varying the size of two metal sleeves and adjusting the distance between these sleeves and the reflectors at the applicator tips. Heating patterns were evaluated on a muscle phantom with a thermograph. At 915 MHz, maximum heating rates of 1.3 and 0.85 degrees C/W-min, respectively, were observed near the tip of the nasopharyngeal applicator and at its first sleeve opening. When operated at 915 MHz the cervical applicator has a maximum heating rate of 0.25 degrees C/W-min at the tip. Clinically, both applicators require a maximum power of 30 W to provide effective heating. This makes it possible to provide intracavitary hyperthermia at rural hospitals and small clinics with a small portable system.

Biomedical Engineering↗

Use of heating rate and specific absorption rate in the hyperthermia clinic.

The specific absorption rate (SAR), which is the mass-normalized rate of energy absorption by a biological body, has been used by hyperthermia researchers to characterize energy deposition and heating patterns in tissues and in biological models. Before thermal diffusion and blood flow alter the temperature distribution, energy deposition and heating rate (HR) are related by constants. Therefore SAR is usually calculated from the initial rate of temperature rise measured during heating. SAR is an appropriate parameter for theoretical calculations or electric field measurement in tissue. However, the ultimate parameter in hyperthermia is temperature. Instead of computing the temperature rise from SAR (W/kg) and specific heat (kcal/kg.degree C) which were originally obtained from temperature measurements, it is simpler and more convenient to use HR (degree C/W-min) directly, especially when heterogeneous tissues are involved. The advantages of using HR instead of SAR in hyperthermia clinics are discussed.

Body Temperature↗

Design of intracavitary microwave applicators for the treatment of uterine cervix carcinoma.

A 915 MHz intracavitary applicator was designed to heat tumours in the cervical and upper vaginal regions. The applicator has a 3.5-turn helical coil wound around the distal 19 mm of a dielectric rod 43 mm long and 30 mm in diameter. For treating uterine cancer, a 2450 MHz, 4 mm diameter helical applicator was made by replacing 6 cm of the outer conductor of a coaxial cable with six turns of copper wire soldered to the outer conductor. The heating patterns were determined thermographically in a muscle phantom. The maximum heating rates were 0.42 and 0.83 degrees C/W-min, respectively, for the 915 and 2450 MHz applicators. Intracavitary temperature distributions in the upper vagina, cervix and uterus were measured at the surface of the applicators with thermocouples. The average temperature was 46.0 +/- 2.1 degrees C (S.D.) at mid-tumour and 44.5 +/- 0.8 degrees C at the tumour periphery. The maximum temperature, up to 51.5 degrees C, was measured at the surface of the cervical applicator. The majority of the patients (28/30) tolerated the investigational treatment without burns or pain. Rectal temperatures were also monitored. The location of the hot-spot (40.7 degrees C) in the rectum, 5-7 cm above the anus, corresponded to the tip of the cervical applicator (47.1 degrees C).

Diathermy↗

Use of thermocouples in the intense fields of ferromagnetic implant hyperthermia.

Thermocouples have been used in the intense fields of ferromagnetic implant hyperthermia for extensive temperature measurements. Electromagnetic interference at 100 kHz is minimized with feed-through filters mounted on a copper plate in a shielded assembly. The thermocouples are temperature compensated in the software by monitoring the temperature of the copper plate. D-shell connectors are used for multiple sensor thermocouple connections and to provide proper shield termination of external cables. The technical approaches of grounding, shielding and filtering are examined, and experiments have been conducted to determine the proper usage of thermocouple during ferromagnetic implant treatments. The dependence of filter performance on thermocouple impedance and the effect of D-shell connections on temperature accuracy have been studied. The results indicate that self-heating due to electromagnetic energy coupled into 51 microns thermocouple leads and unbalanced current along 76 microns leads are insignificant at 100 kHz. But severe heating has been observed in 511 and 813 microns leads, especially in high-conductivity copper wires. By using 25-50 microns thermocouple leads, better than 0.1 degree C accuracy and 0.05 degree C resolution have been achieved during ferromagnetic hyperthermia. At field strength of 1500 A/m, artifacts of 0.03-0.05 degree C are observed.

Biophysical Phenomena↗

FDTD simulations of Clini-Therm applicators on inhomogeneous planar tissue models.

A finite-difference time-domain (FDTD) algorithm was used to compute SAR distributions in planar fat-muscle phantom exposed to the Clini-Therm microwave applicators. The models consisted of a 30 X 30 X 7.5 cm phantom and a 15 X 15 cm, 10 X 10 cm or 7.5 X 7.5 cm aperture dielectric slab loaded applicator. The phantom was either filled with muscle material or with 1.0 cm fat on 6.5 cm muscle. A mineral oil bolus was placed on the fat-muscle model with its integrated water channels parallel to the electric or magnetic field. The FDTD resolution was 3 mm and the applicators were excited with a Gaussian pulse. The computations required 6000-8000 time steps to reach steady state, with 45-48 Mwords on a Cray Y-MP C-90 in 1000-1200 CPU seconds. The electric field components at 915 MHz were obtained by summing the Fourier coefficients at each grid point during each time step and SAR was determined. The results were qualitatively compared to existing and published thermographic heating patterns with good agreement. The computed electric field distributions had provided a three dimensional view into the problem space to investigate and understand wave propagation phenomena in complex inhomogeneous configurations that were not feasible with experimental models.

Adipose Tissue↗

A pilot study of intracavitary hyperthermia combined with radiation in the treatment of oesophageal carcinoma.

Twenty-five patients with primary squamous cell carcinoma of the oesophagus were treated with intracavitary hyperthermia combined with external beam radiation and intraluminal radiation at Nanjing Jinling Hospital, China. External beam radiation was given with a 6-MV X-ray; 1.8-2.0 Gy per fraction and five fractions per week; this brought the total dose to 60 Gy. Two weeks later, hyperthermia was applied with 915 MHz microwave intracavitary applicators, which were designed at the City of Hope. Temperature measurements were obtained while moving fibreoptic temperature sensors at 1.0 cm intervals in each of the six peripheral channels of the applicator. Hyperthermia was applied for 1 h before and after the intraluminal radiation. Intraluminal radiation was provided by low dose-rate iridium-192 ribbons in the same intracavitary applicator, giving 30 Gy at 0.75 cm from the applicator surface. The 3-month post-treatment responses showing complete response, partial response, no change and progressive disease were 60% (15/25), 24% (6/25), 8% (2/25) and 8% (2/25) respectively. The median follow-up time was 17 months (range 4-29 months). The 1- and 2-year overall survival rates were 72% (18/25) and 32% (8/25) respectively, and disease-free survival rates were 47 and 30% respectively. The median overall survival and disease-free survival periods were 17 and 10 months respectively. Fourteen patients had local recurrence (either at the primary site or in the lymph node) or had local progression, and five developed metastases. The median duration of the onset of local recurrence or of local progression was 9.5 months (range 0-20 months); the median of distant metastases was 8 months (range 2-16 months). Seventeen patients died. Of these, 15 died of cancer: six with local recurrence alone, four with local progression primary cancer alone, three with distant metastases alone, and two with both local and distant failure. Two patients with complete response of the primary disease died of other diseases. The toxicity was mild. According to the mucous reaction scoring criteria of the Radiation Therapy Oncology Group, the acute toxicity grades I, II, III and IV were 0% (0/25), 20% (5/25), 48% (12/25) and 32% (8/25) respectively. The major late complication was a mild oesophagus fibrosis and difficult swallowing. No serious side effects (grade IV), fistulas or perforations were seen. These results indicate that this method is safe and feasible for treating oesophageal carcinoma.

Combined Modality Therapy↗

Electrochemical therapy--comparison with other local treatment methods on rat model.

BACKGROUND/AIMS: Electrochemical therapy is an alternative to treat hepatoma. We compare this method with the other local injection methods on rat liver. METHODOLOGY: Five groups of Wister rats (24 in each) were anaesthetized. Electrochemical therapy was set under direct current, 6 volts, electrodes were 0.5 cm apart, 0.5 cm deep into exposed parenchyma for 10 min. Local injection was done with 50 microL of 95% alcohol, 30 microL of 20% acetic acid, 30 microL of 35% hydrochloric acid, and 30 microL of 20% sodium hydroxide via a 27-gauge needle under direct vision into each rat. Rats and their livers were examined postmortem on day 1, 3, 7 and 14. RESULTS: In electrochemical therapy, the treated area showed coagulation necrosis and without blood cells on day 1; then the margin became blurred. Mononuclear cell infiltration, reperfusion and fibrous band formation were prominent from day 3 through day 14. In local injection groups, the necrosis is quite irregular and unpredictable. The regeneration went under similar process. CONCLUSIONS: To destroy tissue locally, electrochemical therapy is unique for its predictability in destructive area and the recovery process and is as effective as the other injection methods. Therefore, it has great potential for hepatoma treatment.

Acetic Acid↗

Basic problems of diversely reported biological effects of radio frequency fields.

The large differences in RF safety standards are due to different philosophical approaches to public health standards development, different scientific approaches and interpretations of the scientific data, and different jurisdictions in various countries. In this paper, the origin of these differences is explored. The emphases are on the basic problems of why reported biological effects of RF fields are controversial, and how the general public can be misinformed. While there are differences in approaches and methods, science should converge and not diverge in finding the threshold level for exposure to EMF that is not adverse to human health. As the progress in technology continues and human beings are enjoying an increased quality of life, it is essential for scientists to ensure that safety is not compromised. More importantly, it is the responsibility and moral obligation of scientists and the media to bring "verified" information to the public. Scientists must conduct well-designed studies and to report the results in a clear and detailed manner, so other independent investigators can repeat the study or explore further. Mistakes must be minimized and stopped at the first level of scientific research.

Animals↗

Liquid chromatographic determination of benzoyl peroxide in acne preparations.

A rapid, precise, and accurate liquid chromatographic (LC) method is described for the determination of benzoyl peroxide (BP) in acne preparations. BP is extracted from a water dispersion of the preparation with dichloromethane (DCM), and an aliquot is eluted from a C-18 reverse phase LC column with acetonitrile-0.10 M aqueous NaClO4. Selective and sensitive quantitation is accomplished with a reductive mode electrochemical detector. This detector is an order of magnitude more sensitive than a 240 nm UV absorption detector; the lower limit of detection is 2 ng for a 4 microL injection. The recovery of BP is 99.4% and the detector response is linear to at least 2 micrograms per 4 microL injection.

Acne Vulgaris↗