PubMed Health⌕ Search

Biomedical subjects

C Kawakami

Publications and source records attributed to C Kawakami.

11 recordsLinked to original sources

Infiltration of cervical lymph nodes by B- and T-cell non-Hodgkin's lymphoma and Hodgkin's lymphoma: preliminary ultrasonic findings.

Ultrasonography has been used in the evaluation of enlarged lymph nodes in patients with malignant lymphoma, which comprises a variety of histopathological subtypes. We assessed ultrasonic findings of infiltration in cervical lymph nodes of 47 patients with previously untreated malignant lymphoma and correlated them with histopathological subtypes. Common findings among various histopathological subtypes were hypoechoic masses, spot and/or line echoes, involvement of multiple nodes, and posterior enhancement. In addition, each histopathological subtype showed characteristic findings: Hodgkin's disease had a contour with a lobular pattern (9/10 cases), septum-like echo (9/10 cases), and tubular structure (9/10 cases) in the internal echo, reflecting histopathologically fibrous connective tissue surrounding lymph nodes and small vessels. In B-cell lymphoma, there was characteristically a tendency for lymph node fusion (19/28 cases) and spot and/or line echoes (17/28 cases), reflecting histopathological replacement and destruction of the structure of lymph node and capsule by proliferation of lymphocytes. These findings were strengthened in diffuse large B-cell lymphoma. T-cell lymphoma was distinguished from other types of lymphoma by the presence of a hilum-like echo (6/9 cases), reflecting histopathologically prominent vascularization in lymph nodes accompanied by a dilated hilum area. In summary, this preliminary study suggests that ultrasonic findings of infiltration of cervical lymph nodes in major subtypes of malignant lymphoma could reflect characteristic histopathological structures, therefore providing information helpful for differentiating them.

Adult↗

[Evaluation of immunochromatography method for rapid detection of influenza A and B viruses].

We have evaluated a new rapid detection kit for influenza A and B viruses, known as the QuickVue Influenza test (Quidel Coporation, USA); which is based on immunochromatography using virus isolates and clinical specimens. Twelve strains of influenza A and B were tested for evaluate the reactivity and detection limits of this test. The QuickVue Influenza test showed a positive result for all twelve strains of influenza virus and a negative result for fourteen different kinds of other respiratory viruses. The detection limits for six strains were 5 to 30 pfu/ml for a cell culture, 1.0 x 10(3) to 6.0 x 10(4) pfu/ml for 1st PCR, 1 to 50 pfu/ml for nested PCR, 3.0 x 10(5) to 6.0 x 10(5) pfu/ml for the QuickVue Influenza test, 1.5 x 10(5) to 1.0 x 10(6) pfu/ml for the Directigen Flu A, and 7.5 x 10(5) to 5.0 x 10(6) pfu/ml for the FLU OIA. Furthermore, the QuickVue Influenza test were clinically evaluated using 92 throat swab specimens collected from patients with influenza-like illnesses. By cell culture, influenza viruses were detected in 49 of the 92 specimens (AH1N1: 20, AH3N2: 7, B: 22); the titers of the influenza viruses were between 2.5 pfu/ml and 7.0 x 10(5) pfu/ml. Compared to cell culture, the QuickVue Influenza test showed a sensitivity of 75.5%, a specificity of 93.0%, a positive predictive value of 92.5%, a negative predictive value of 76.9%, and an efficiency value of 83.7%. On the other hand, influenza viruses were detected in 54 of the 92 specimens (AH1N1: 19, AH 3N2: 10, B: 25) by RT-PCR. Compared to RT-PCR, the QuickVue Influenza test showed a sensitivity of 72.2%, a specificity of 97.4%, a positive predictive value of 97.5%, a negative predictive value of 71.2%, and an efficiency value of 82.6%. Overall, only one throat swab specimen produced a false positive result using the QuickVue Influenza test; thus, this test appears to have a high specificity. We conclude that the QuickVue Influenza test is a simple one-step test with a sensitivity and specificity equivalent to those of other conventional diagnostic kits. The test is useful and suitable for the diagnosis of influenza and for identifying influenza patients requiring antiviral therapy.

Influenza A virus↗

A scoring system for ultrasonographic differentiation between cervical malignant lymphoma and benign lymphadenitis.

The purpose of our study is to assess the usefulness of a scoring system for ultrasonography using a high-frequency transducer as a non-invasive examination in the differential diagnosis of cervical malignant lymphoma from benign lymphadenitis. Ultrasonography was performed with a real-time linear scanner using 7.5 and/or 11 MHz probes in 66 patients who were presented with cervical lymphadenopathy and were suspected to have malignant lymphoma. Thereafter, a surgical biopsy was performed for histopathological diagnosis, revealing 49 cases of malignant lymphoma and 17 cases of benign lymphadenitis. Ultrasonographic findings were reviewed retrospectively. The incidence of following ultrasonographic features was found to be significantly higher in malignant lymphoma than in benign lymphadenitis. These were; (1) longitudinal and transverse diameter ratio(L/T) < 2.0, (2) a delineation of multiple nodes, (3) a tendency of fusion, (4) an irregular margin, (5) hypoechoic masses with heterogeneous internal echoes, (6) a presence of line echoes and (7) an absence of hilum. These 7 ultrasonographic features were used in combination for a scoring system to discriminate malignant lymphoma from benign lymphadenitis. When ultrasonographic findings of lymph nodes fulfilled more than 3 of the 7 features, malignant lymphoma was diagnosed with a sensitivity of 98.0% and a specificity of 76.5%. Ultrasonographic evaluation of swollen cervical lymph nodes using a high-frequency transducer would be informative and should be performed prior to a surgical biopsy.

Adolescent↗

[Sensitivity and specificity of rapid diagnosis kit detecting separately influenza A and B viruses].

Sensitivity and specificity of the Directigen Flu A + B kit, a rapid test for influenza virus A and B, were evaluated. This test detects influenza A and B viruses separately by EIA. Reactivity of the kit was tested using a total of 23 isolates: 13 isolates of human influenza virus A (H1N1, H3N2) and 10 isolates of human influenza virus B. All of the isolates were tested positive and no difference in reactivity was found in antigenic variables and subtypes. The kit was only reactive to influenza virus A and B, not reactive to other viruses. Typical influenza A and B strains were tested for detection limit. 7.8 x 10(3) pfu/ml was a detection limit for influenza virus A (H1N1: Beijing/262/95), 4.7 x 10(4) pfu/ml for influenza virus A (H3N2: Kitakyusyu/159/93), and 3.1 x 10(4) pfu/ml for influenza virus B (Guangdong/05/94). The Directigen Flu A + B kit was a easy-to-use, rapid detection device and the kit has sensitivity and specificity equivalent to other diagnostic devices, suggesting the kit are useful in medical institutions.

Evaluation Studies as Topic↗

[Evaluation of an optical immunoassay test for rapid detection of influenza A and B viral antigen].

An optical immunoassay test, FLU OIA (BIOSTAR, USA), was evaluated for the diagnosis of influenza viral infection. The reactivity of the FLU OIA test was evaluated using 42 influenza strains (25 human influenza A, 12 human influenza B, 2 swine influenza A and 3 avian influenza A strains). The FLU OIA test showed positive results for all influenza strains. There was no evidence that cross-reactivity occurred with non-influenza viruses. The detection limit of the FLU OIA test was found to be 3.0-6.5 x 10(4) pfu/assay for human influenza A and B strains. The sensitivity and specificity of the FLU OIA test compared to isolation in cell culture was 89.7% and 76.0% for testing of 54 nasopharyngeal aspirate specimens. The FLU OIA test is rapid and easy for the detection of influenza A and B viral antigen and provide a valuable tool for the rapid diagnosis of influenza viral infection.

Antigens, Viral↗

[Evaluation of a rapid enzyme immunoassay membrane test for diagnosis of influenza A virus infection].

A rapid enzyme immunoassay membrane test, Directigen Flu A (Becton Dickinson, USA), was evaluated by using virus isolates and clinical specimens. The reference laboratory diagnosis was based on the results of virus isolation. Directigen Flu A was reactive for all subtypes of human influenza A viruses, including reference strains of H1N1, H2N2 and H3N2. Moreover, H5N1 (Hongkong/156/97) was also detected by this kit. No cross reactivity was detected with other respiratory viruses. Directigen Flu A showed positive reaction with the solution containing influenza A virus of 2.4 x 10(3) pfu/assay. The rapid test demonstrated 77.9% sensitivity and 98.4% specificity for testing of throat swabs from children with respiratory symptoms. It showed higher sensitivity and specificity (92.1% and 100%) for testing of nasopharyngeal aspirates. Directigen Flu A should be useful for the rapid diagnosis of influenza A virus infection.

Antigens, Viral↗

Fibrinolytic activity in periodontal disease. The relationship between fibrinolytic activity and severity of periodontal disease.

IN RECENT YEARS, evidence has evolved that suggests a relationship between fibrinolytic phenomenon and various inflammatory diseases. Plasmin activity and the response of the fibrinogen and fibrin degradation products latex test (FDPL test) in gingival fluid, along with plasminogen activator activity in gingival tissue were assessed. Samples were taken from periodontally involved persons and compared with healthy individuals. The following conclusions could be drawn: (1) The fluid from inflamed gingival crevices possessed more plasmin activity than that from clinically healthy crevices. The reaction of the FDPL test was stronger in the former. (2) Plasminogen activator activity in gingival tissue showed no significant difference between periodontally involved and healthy subjects.

Alveolar Process↗