PubMed Health⌕ Search

Biomedical subjects

C Kremser

Publications and source records attributed to C Kremser.

At least 37 records · Page 2Linked to original sources

A subanesthetic concentration of sevoflurane increases regional cerebral blood flow and regional cerebral blood volume and decreases regional mean transit time and regional cerebrovascular resistance in volunteers.

Inhaled anesthetics exert metabolically mediated effects on cerebral blood vessels both directly and indirectly. We investigated the effects of a 0.4 minimum alveolar subanesthetic concentration of sevoflurane on regional cerebral blood flow (rCBF), regional cerebral blood volume (rCBV), regional cerebrovascular resistance (rCVR), and regional mean transit time (rMTT) in volunteers by means of contrast-enhanced magnetic resonance imaging perfusion measurement. Sevoflurane increased rCBF by 16% to 55% (control, 55. 03 +/- 0.33 to 148.83 +/- 1.9 mL. 100 g(-1). min(-1); sevoflurane, 71.75 +/- 0.36 to 193.26 +/- 2.14 mL. 100 g(-1). min(-1)) and rCBV by 7% to 39% (control, 4.66 +/- 0.03 to 10.04 +/- 0.12 mL/100 g; sevoflurane, 5.04 +/- 0.03 to 13.6 +/- 0.15 mL/100 g); however, sevoflurane decreased rMTT by 7% to 18% (control, 3.75 +/- 0.04 to 5. 39 +/- 0.04 s; sevoflurane, 3.4 +/- 0.03 to 4.44 +/- 0.03 s) and rCVR by 22% to 36% (control, 0.74 +/- 0.01 to 1.9 +/- 0.2 mm Hg/[mL. 100 g(-1). min(-1)]; sevoflurane, 0.54 +/- 0.01 to 1.41 +/- 0.01 mm Hg/[mL. 100 g(-1). min(-1)]). Interhemispheric differences in rCBF, rCBV, and rCVR were markedly reduced after the administration of sevoflurane. These findings are consistent with the known direct vasodilating effect of sevoflurane. The decrease in rMTT further shows that rCBF increases more than does rCBV. Furthermore, we can show that the observed increase in rCBF during inhalation of sevoflurane is not explained by vasodilation alone.

Adult↗

Monitoring of tumor microcirculation during fractionated radiation therapy in patients with rectal carcinoma: preliminary results and implications for therapy.

PURPOSE: To measure microcirculatory changes during chemoirradiation and to correlate perfusion index (PI) values with therapy outcome. MATERIALS AND METHODS: Perfusion data in 11 patients with cT3 (clinical staging, tumor invaded the perirectal tissue) rectal carcinoma who underwent preoperative chemoirradiation were analyzed. Perfusion data were acquired by using a T1 mapping sequence with a whole-body magnetic resonance (MR) imager. After contrast medium was intravenously infused at a constant rate, concentration-and-time curves were evaluated for arterial blood and tumor. All patients underwent MR imaging before and at constant intervals during chemoirradiation. Clinical stages before therapy were compared with surgical stages after therapy. RESULTS: Spatial and temporal resolution on dynamic T1 maps were sufficient to reveal changes in contrast medium accumulation in the tumor. Comparison of PI values and radiation dose showed a significant increase in the 1st (P: =.003) and 2nd weeks (P: =.01) of treatment; values subsequently returned to pretreatment levels or showed a renewed increase. High initial PI values correlated with greater lymph node downstaging (P: =.042). CONCLUSION: Dynamic T1 mapping provides a suitable tool for monitoring tumor microcirculation during chemoirradiation and offers the potential for individual optimization of therapeutic procedures. Furthermore, these results indicate that the PI map may serve as a prognostic factor.

Adenocarcinoma↗

The impact of increased mean airway pressure on contrast-enhanced MRI measurement of regional cerebral blood flow (rCBF), regional cerebral blood volume (rCBV), regional mean transit time (rMTT), and regional cerebrovascular resistance (rCVR) in human volunteers.

Contrast-enhanced magnetic resonance imaging (MRI) measurement of cerebral perfusion is a diagnostic procedure increasingly gaining access to clinical practice not only in spontaneously breathing patients but also in mechanically ventilated patients. Effects of increased mean airway pressure on cerebral perfusion are entirely possible. Therefore, the present study used continuous positive airway pressure (CPAP) (12 cm H2O) to study the effects of increased mean airway pressure on cerebral perfusion in volunteers. CPAP significantly reduced regional cerebral blood flow (rCBF) and regional cerebral blood volume (rCBV) but increased regional mean transit time (rMTT) and regional cerebrovascular resistance (rCVR). Active vasoconstriction (e.g., arterial) and/or passive compression of capillary and/or venous vessel areas are the most likely underlying mechanisms. The number of interhemispheric differences in rCBF, rCBV, rMTT, and rCVR found at baseline rose when mean airway pressure was increased. These results, although obtained in volunteers, should be taken into consideration for the interpretation of contrast-enhanced MRI perfusion measurements in mechanically ventilated patients with an increased positive airway pressure.

Analysis of Variance↗

Magnetic resonance imaging and cochlear implants: compatibility and safety aspects.

With cochlear implants, magnetic resonance imaging (MRI) has until recently been contraindicated due to excessive magnetic and electromagnetic interference. The aim of this study was to determine the MRI compatibility of the Med-E1 Combi 40/40+ cochlear implant, within a wide range of clinical MRI applications. In vitro experiments on a 1.5 T MR scanner were performed. Torque, force, demagnetization, artifacts, induced voltages, and temperature increase were measured in worst case scenarios for the implant. In addition, stabilization experiments were performed. It was shown that most of the electromagnetic interferences between the cochlear implant and the 1.5 T scanner remained within acceptable limits. One exception is the torque on the internal magnet, which represents a hazard for patients with these cochlear implants. Therefore, MRI examination should only be performed if there is a strong medical indication, and certainly some assessment of the relative risks involved versus the risk of not providing the diagnostic capabilities of MRI, will have to be made. Appropriate safety measures should be taken.

Artifacts↗

[Development and application of dynamic MR imaging in the evaluation of perfusion changes in rectal carcinoma during radiotherapy in clinical routine. Preliminary results].

PURPOSE: This study was aimed at measuring microcirculatory parameters and contrast medium accumulation within the rectal carcinoma during fractionated radiotherapy in the clinical setting. MATERIAL AND METHODS: Perfusion data were observed in patients with rectal carcinoma (n = 8) who underwent a pre-operative combined chemo/radiotherapy. To acquire perfusion data, an ultrafast T1 mapping sequence was carried out on a 1.5-Tesla whole body imager to obtain T1 maps at intervals of 14 or 120 seconds. The overall measurement time was 40 minutes. The transaxial slice thickness (5 mm) was chosen in such a way that both arterial vessels and the tumor could be clearly identified. The gadolinium-DTPA (Gd-DTPA) concentration time curve was evaluated for arterial blood and tumor after intravenous constant rate infusion. The method allows a spatial resolution of 2 x 2 x 5 mm and a temporal resolution of 14 seconds. Patients underwent MR imaging before and at constant intervals during fractionated radiotherapy. RESULTS: Spatial and temporal resolution of dynamic T1 mapping was sufficient to reveal varying CM accumulation levels within the tumor and to identify the great arteries in the pelvis. In 6 patients Gd-DTPA concentration-time-curves were evaluated within the tumor during radiation. Pi index of Gd-DTPA versus radiation dose showed a significant increase in the first or second week of treatment, then either returned slowly to pretreatment level or a renewed increase was observed. The average Pi-value at the beginning was 0.16 (+/- 0.049), reaching highest level of 0.23 (+/- 0.058). In all groups the rise from the Pi-value to the Pi-maximum was statistically significant. The relative increase in perfusion ranged between 20 to 83%. CONCLUSION: The results show, that the ultrafast MR-technique described above provide a suitable tool for monitoring tumor microcirculation during therapeutic interventions and offers the potential for an individualized optimization of therapeutic procedures.

Aged↗

Functional magnetic resonance imaging of the human motor cortex before and after whole-hand afferent electrical stimulation.

Electrical stimulation of the whole hand using a mesh-glove has been shown to improve volitional movement of the hand and arm, and decrease muscle hypertonia after hemispherical stroke in patients who have reached a recovery plateau. The goal of this study was to investigate the effect of stimulation of the nerve afferents of the hand on brain cortical activity elicited by whole-hand subthreshold stimulation for sensation in humans with intact nervous systems. Brain cortical activity in 6 healthy subjects (30-45 years) was studied using blood oxygenation level-dependent functional Magnetic Resonance Imaging during a test motor task, finger-to-thumb tapping and after 20 minutes of mesh-glove stimulation of the resting hand prior to performance of an identical motor task, to test the changes in the conditioned motor task established after 20 minutes of mesh-glove stimulation. Fifteen contiguous echo-planar sequences parallel to the bicommissural plane were acquired for functional magnetic resonance. Post-processing of image data included correction of motion artefacts and calculation of correlation coefficients between the signal intensity of pixels during rest and finger tapping and a rectangular reference wave function. The functional Magnetic Resonance Imaging examinations revealed a signal increase in the primary and secondary motor and somatosensory areas when comparing the number of activated pixels during test and conditioned motor tasks. Our preliminary study indicated that change occurred in a definite pattern in the region of the regional cerebral blood flow of the brain cortex after mesh-glove whole-hand stimulation at the subthreshold level for sensation. We assumed that this increase in regional cerebral blood flow also reflected augmented neuronal activity.

Adult↗

Effects of hyperoxia and hypocapnia on regional venous oxygen saturation in the primary visual cortex in conscious humans.

Hyperoxia can improve oxygen delivery in patients exposed to hypocapnia for neurosurgical procedures but this effect may be modified by regional differences in the degree of hypocapnic vasoconstriction. Using functional magnet resonance imaging (fMRI), we have investigated the influence of hyperoxia on blood flow and blood oxygenation in the primary visual cortex in hypocapnic volunteers. Consecutive fMRI measurements were performed in 10 awake, male volunteers during hypocapnia (mean PE'CO2 3.3 (SD 0.1) kPa) and normocapnia (PE'CO2 5.3 (0.1) kPa) at FIO2 values of 0.21 and 1.0, respectively. Hypocapnia significantly reduced the pixel count in the primary visual cortex (median 169 (quartiles 34-246) vs 21 (0-40) pixels at an FIO2 of 0.21). Additional hyperoxia had no influence on this reduction in pixel count (16 (0-28) pixels at FIO2 1.0 vs 21 (0-40) pixels at FIO2 0.21). Hyperoxia did not influence hypocapnic vasoconstriction in the primary visual cortex. These data suggest that in the primary visual cortex, administration of oxygen alone may not be sufficient to improve oxygen delivery under hypocapnic conditions.

Adult↗

Phase-contrast MRI measurement of systolic cerebrospinal fluid peak velocity (CSFV(peak)) in the aqueduct of Sylvius: a noninvasive tool for measurement of cerebral capacity.

BACKGROUND: Cerebrospinal fluid (CSF) outflow to intra- and extracranial subarachnoid spaces caused by arterial inflow to the brain predominantly compensates systolic increases in cerebral blood volume. Phase-contrast magnetic resonance imaging is a new tool for noninvasive assessment of CSF displacement by measuring CSF peak velocity (CSFV(Peak)). The authors tested this new tool in an experimental human model of increased intracranial pressure and reduced cerebral capacity by means of continuous positive airway pressure (CPAP) breathing. METHODS: The authors investigated systolic CSFV(Peak) in the aqueduct of Sylvius in 11 awake, normocapnic (end-tidal carbon dioxide [ET(CO2)] = 40 mmHg) volunteers without CPAP and at two different CPAP levels (6 and 12 cm H2O) by means of electroencephalography-gated phase-contrast magnetic resonance imaging. RESULTS: Administration of 6 cm H2O CPAP did not change systolic CSFV(Peak) (-4.9+/-2.8 cm/s vs. control: -5.1+/-2.7 cm/s), whereas 12 cm H2O CPAP significantly reduced systolic CSFV(Peak) (-4.0+/-1.8 cm/s vs. control: -5.1+/-2.7 cm/s; P < 0.05). CONCLUSIONS: These findings in awake volunteers show that monitoring CSFV(Peak) in the aqueduct of Sylvius is a sensitive method for detecting even minor impairment of cerebral capacity caused by experimentally induced increases in intracranial pressure.

Adult↗

Transcranial Doppler sonography guided by magnetic resonance angiography for improved monitoring of intracranial arteries.

Transcranial Doppler (TCD) sonography combines the advantages of real-time hemodynamic information, cost-effectiveness, and bedside application. However, measurements can be difficult to reproduce because the spatial resolution and the determination of insonation angles are limited. The purpose of this study was to use the high anatomic resolution of three-dimensional (3D) magnetic resonance angiography (MRA) images for the stereotactic guidance of TCD in order to improve the accuracy and reproducibility of TCD examinations. The MRA examinations were performed on a 1.5 T scanner using a 3D flow compensated gradient-echo sequence. A noninvasive stereotactic mask was used for image registration. The MRA data were then transferred to a personal computer. An infrared tracking system registered the position of the head and the ultrasound probe during TCD. This enabled the authors to superimpose a virtual ultrasound beam onto the MRA projections of the intracranial arteries displayed on the monitor of the personal computer. This allows the examiner to easily identify the insonated intracranial artery and displays the insonation angle. In volunteer examinations (n = 10), the accuracy and reproducibility for the localization of specific vessel segments was 2.48 mm for the middle cerebral artery and 2.81 mm for all insonated intracranial arteries (middle cerebral artery, anterior cerebral artery, internal carotid artery, and posterior cerebral artery). Without navigation the reproducibility of vessel segment insonation dropped to 4.7 mm for the middle cerebral artery and to 4.84 mm for all vessels. The authors conclude that 3D MRA, acquired as an initial procedure in patients with intracranial vascular disorders, can be used to provide stereotactic guidance for repeated TCD examinations. This facilitates the reproducible insonation of specific vessel segments.

Adult↗

[Transcranial Doppler ultrasonography: stereotactically guided examinations using magnetic resonance angiography].

The accurate localization of specific intracranial blood vessels is a major difficulty with transcranial Doppler sonography (TCD). It was the purpose of this study to develop a system enabling stereotactic navigation during a TCD examination on the basis of high-resolution three-dimensional magnetic resonance angiographic (MRA) data. During TCD, the examiner is provided--on a computer screen--with a projected view of the respective intracranial vessel anatomy. With the aid of an optoelectronic localization system, the spatial orientation and localization of the US probe is determined in real time, and correlated with the patient's MRA data using a dedicated stereotactic mask. Subsequently, the US beam and the points of insonation are displayed on the screen overlaid on the vessel anatomy. In this way the examiner gains real time control of the localization of the respective intracranial vessel insonated. Points of insonation can be stored and recalled for follow-up examinations. In addition to the successful verification of the system, it was shown that, in comparison with conventional TCD, stereotactic navigation distinctly improves the reproducibility of repeat TCD examinations.

Humans↗

Hippocampal volume reduction in male schizophrenic patients.

Using magnetic resonance imaging of the brain, we examined volumetric measurements of total brain, hemispheres, lateral ventricles and the hippocampus/amygdala complex in male subjects (41 first-episode schizophrenics, 30 chronic schizophrenic patients and 32 healthy controls). We found significantly smaller total brain size in the chronic schizophrenic group, significantly larger lateral ventricles in both patient groups and hippocampal volume reduction bilaterally in first-episode patients (-13.2% left, -12.05% right) and chronic patients (-10.6% left, -10.5% right) compared to controls--irrespective of diagnostic subtype, family history for psychiatric diseases, psychopathology, duration of illness or age at onset.

Adult↗

Metallic artifacts in magnetic resonance imaging of patients with spinal fusion. A comparison of implant materials and imaging sequences.

STUDY DESIGN: Devices for spinal fusion were compared with respect to their influence on magnetic resonance images. In addition, different magnetic resonance pulse sequences were evaluated to elicit their susceptibility to imaging artifacts. OBJECTIVES: To determine the implants with the least imaging artifacts as a recommendation for the spine surgeon and to assess the best imaging strategy for the radiologist. SUMMARY OF BACKGROUND DATA: For patients who have had surgical spinal fusion with instrumentation, magnetic resonance imaging is the most favorable diagnostic method. Unfortunately, metallic implants lead to severe degradation of image quality. These artifacts depend on the material of the implant and on the choice of the pulse sequence. METHODS: The fusion devices were mounted on a simple plastic phantom in various combinations and were imaged on 1.5-T magnetic resonance units. Frequently used types of plates and screws made of titanium or steel in various alloys were examined on the phantom with routinely used pulse sequences. The results of these examinations were compared with those in patient studies involving the same implants as well as the same pulse sequences. RESULTS: The least imaging artifacts were caused by titanium implants, especially when using shorter screws, wider screw placement, and thinner titanium plates. Nevertheless, there were distinct image distortions that could lead to erroneous image interpretation. The best images were acquired by spin echo (T1), turbo spin echo (T1, T2), and half Fourier single shot turbo spin echo (HASTE) sequences. Sequences containing any gradient echo components (gradient echo or turbo gradient and spin echo sequence or frequency-selective fat saturation techniques) resulted in the highest amount of image degradation. CONCLUSION: By choosing appropriate spinal fusion devices as well as pulse sequences, postoperative magnetic resonance imaging examinations can give acceptable results, in spite of the presence of metallic implants.

Adolescent↗

Three-dimensional computer assisted magnetic resonance imaging for neurosurgical planning in parasagittal and parafalcine central region tumors.

Usually, conventional magnetic resonance spin echo images (MRI) are sufficient to establish the diagnosis of intracranial pathology. Planning and executing a neurosurgical procedure requires the ability of the neurosurgeon to transform these two-dimensional MRI into a three-dimensional (3-D) virtual image of the pathology and the surrounding neuronal anatomy. Such mentally performed transformations after sequential observation of the individual two-dimensional slices (i.e., MRI and angiography) may be virtual tasks that are very difficult or sometimes impossible to achieve. Using 3-D MRI data sets and a semiautomatic computer assisted segmentation technique, we tried to simulate intraoperative situs-based 3-D MRI reconstructions of parasagittal and parafalcine central region tumors. The MRI reconstructions were integrated into the neurosurgical planning procedure as an additional tool. They proved to be an important adjunct in determining the distinct anatomy of the intracranial pathology in its relation to the surrounding and overlying brain and vascular (especially venous) anatomy. With 10 patients with central region parasagittal and parafalcine tumors, we found that the 3-D MRI reconstructions revealed additional information compared to conventional cross-sectional images and had an influence on neurosurgical planning and strategy, improving neurosurgical performance and patient outcome.

Humans↗

The therapeutic potential of oral creatine supplementation in muscle disease.

The decrease in intracellular creatine concentration observed in a number of muscle diseases may deplete energy homeostasis and may, therefore, be one of the factors determining and/or aggravating muscle weakness and degeneration. Two hypotheses are put forward in the present communication to explain: (i) the mechanisms leading to the disturbances in creatine metabolism found in various muscle diseases; and (ii) the potential of oral creatine supplementation in alleviating the clinical symptoms.

Animals↗

Cochlear implants: in vitro investigation of electromagnetic interference at MR imaging--compatibility and safety aspects.

In vitro experiments were performed to determine the compatibility of a cochlear implant at 0.2- and 1.5-T magnetic resonance (MR) imaging. Except for the torque at 1.5 T, all electromagnetic interferences remained within acceptable limits. MR imaging should be performed only if there is a strong medical indication, by following appropriate safety procedures. MR imaging at 0.2 T should be safe; at 1.5 T, however, the relative risks will have to be assessed.

Cochlear Implants↗

Three-dimensional navigation in otorhinolaryngological surgery with the viewing wand.

We report our experiences with the ISG Viewing Wand intraoperative 3-dimensional navigation device in endonasal endoscopic procedures of the paranasal sinuses, anterior skull base, and petrous bone. In the last 12 months we have routinely used the wand in 90 patients for treatment of polyposis nasi, for biopsies and removal of tumors in the nasal cavity and at the frontal skull base, for endocrine ophthalmopathy, and in 1 case for cholesteatoma. We present our computed tomography, magnetic resonance imaging, and clinical protocols that allow a precise routine use of the Viewing Wand. In all cases, the system was extremely helpful for intraoperative localization and helped to optimize surgery.

Equipment Design↗