PubMed Health⌕ Search

Biomedical subjects

C L Birkett

Publications and source records attributed to C L Birkett.

6 recordsLinked to original sources

Development of baroreflex influences on heart rate variability in preterm infants.

To investigate developmental changes in autonomic cardiovascular reflexes in preterm infants, we used autoregressive power spectral analysis to analyze the effect of upright tilting on heart rate variability in preterm infants. Twenty-eight infants were studied in a longitudinal fashion beginning at 28-32 weeks postconceptional age (postnatal age 1-5 weeks). Each week, heart rate variability in the supine position and after 45 degrees head-up tilt was analyzed by spectral analysis. With the initial study of each infant, there was no significant change in heart rate following head-up tilt compared with baseline (-0.5+/-0.9 bpm). However, linear regression analysis revealed that with increasing postnatal age, the change in heart rate in response to tilting became more positive (mean slope of regressions 0.45+/-0.12 bpm/week, P<0.005). The power spectral density of R-R interval variability in the low-(LF; 0.02-0.15 Hz) and high-(HF; 0.15-1.5 Hz) frequency ranges were obtained and the values normalized by dividing each component by the total power. For measurements obtained in the supine position, the LF/HF ratio progressively decreased with increasing postnatal age, indicating a maturational change in sympathovagal balance. We used the difference in the LF/HF ratio between tilt and the recumbent position as a measure of the change in autonomic input to the heart in response to unloading of the arterial baroreceptors. No significant change in these ratios were observed when infants were first studied between 28 and 32 weeks postconceptional age, suggesting that the cardiac baroreflex is poorly developed at this stage of development. However, with postnatal maturation, the LF component of the power spectrum became progressively larger with tilt relative to the basal state, such that the difference between LF/HF(tilt) and LF/HF(base) became progressively more positive (P <0.006). These findings suggest that in premature infants, cardiac baroreceptor reflexes become more functional with postnatal development.

Aging↗

Encircling overlapping multipulse shock waveforms for transthoracic defibrillation.

OBJECTIVES: This study was performed to determine the efficacy of new encircling overlapping multipulse, multipathway waveforms for transthoracic defibrillation. BACKGROUND: Alternative waveforms for transthoracic defibrillation may improve shock success. METHODS: First, we determined the shock success achieved by three different waveforms at varying energies (18-150 J) in 21 mongrel dogs after short-duration ventricular fibrillation. The waveforms tested included the traditional damped sinusoidal waveform, a single pathway biphasic waveform, and a new encircling overlapping multipulse waveform delivered from six electrode pads oriented circumferentially. Second, in 11 swine we compared the efficacy of encircling overlapping multipulse shocks given from six electrode pads and three capacitors versus encircling overlapping shocks given from a device utilizing three electrodes and one capacitor. RESULTS: In the first experiment, the encircling overlapping waveform performed significantly better than biphasic and damped sinusoidal waveforms at lower energies. The shock success rate of the overlapping waveform (six pads) ranged from 67+/-4% (at 18-49 J energy) to 99+/-3% at > or = 150 J; at comparable energies biphasic waveform shock success ranged from 26+/-5% (p < 0.01 vs. encircling overlapping waveforms) to 99+/-5% (p = NS). Damped sinusoidal waveform shock success ranged from 4+/-1% (p < 0.01 vs. encircling overlapping waveform) to 73+/-9% (p = NS). In the second experiment the three electrode pads, one capacitor encircling waveform achieved shock success rates comparable with the six-pad, three-capacitor waveform; at 18-49 J, success rates were 45+/-15% versus 57+/-12%, respectively (p = NS). At 100 J, success rates for both were 100%. CONCLUSIONS: We conclude that encircling overlapping multipulse multipathway waveforms facilitate transthoracic defibrillation at low energies. These waveforms can be generated from a device that requires only three electrodes and one capacitor.

Animals↗

Is there an optimal electrode pad size to maximize intracardiac current in transthoracic defibrillation?

Achieving defibrillation depends on adequate intracardiac current. The purpose of this study was to determine, in advance of administering shocks which parameters of body habitus can be used to select the electrode size that maximizes intracardiac current in transthoracic defibrillation. We administered direct current shocks to 18 mongrel dogs over a wide range of weight and size (weight 10-30 kg with chest circumferences 44-77 cm) using a damped sine wave defibrillator and self-adhesive electrode pairs of various diameters (4 cm, 5.8 cm, 8 cm and 10 cm), placed on the right and left lateral chest walls. The energy levels used were 50, 100, and 150 J. Intracardiac voltage gradient, a parameter of intracardiac current, was determined in three orthogonal planes using an intramyocardial electrode array placed in the interventricular septum. The relation between intracardiac voltage gradient magnitude magnitude of VG and various parameters (body weight, chest, circumference, chest volume, chest radius, and heart weight divided by chest radius) was determined. The correlation (r) with the smallest P value was between magnitude of VG and the heart weight divided by chest radius (HW/R) (r = 0.71). Intracardiac current was highest at intermediate pad sizes. The electrode pads that maximized magnitude of VG tended to be large for the larger HW/R dogs, and smaller HW/R dogs. In none of the HW/R groups did the largest electrode pads yield the highest intracardiac voltage gradient. We conclude that there is no simple way to determine in advance an electrode pad size that maximizes intracardiac current. The HW/R ratio influences but does not determine intracardiac intracardiac current.

Animals↗

Clinical, hemodynamic and sympathetic neural correlates of heart rate variability in congestive heart failure.

Heart rate (HR) variability has long been recognized as a sign of cardiac health. In the presence of heart disease, HR variability decreases, an observation that has been associated with poor prognosis in a number of recent studies. HR variability is particularly altered in congestive heart failure (CHF), a condition associated with a number of typical functional hemodynamic and neurohumoral alterations. The relation of measurements of HR variability to these abnormalities in patients with heart failure has not been carefully examined. Twenty-three patients (19 men, 4 women, mean age 49 years) with New York Heart Association class II to IV CHF were studied prospectively without cardiac medications; radionuclide ventriculography, right-sided heart catheterization, peroneal microneurography, plasma norepinephrine and 24- to 48-hour ambulatory electrocardiography were performed. Average RR interval and its standard deviation, and HR power spectrum (0 to 0.5, 0.05 to 0.15 and 0.2 to 0.5 Hz) were derived from the ambulatory electrocardiographic recordings and compared with left ventricular ejection fraction, thermodilution cardiac output, pulmonary arterial wedge pressure, New York Heart Association class, age, muscle sympathetic nerve activity (peroneal nerve) and norepinephrine level by linear regression. None of the measures of HR variability were significantly related to age, left ventricular ejection fraction, cardiac output or functional classification, whereas the 0.05 to 0.15 and 0.20 to 0.50 Hz components were weakly but significantly related to cardiac output (r = 0.49 and 0.42, p = 0.02 and 0.045, respectively). In contrast, a generally stronger and negative relation was demonstrated between spectral and nonspectral measurements of HR variability, and indicators of sympathoexcitation, muscle sympathetic nerve activity and plasma norepinephrine.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

A signal-averaging technique for the analysis of human muscle sympathetic nerve activity.

We present a signal-averaging technique for analysis of human muscle sympathetic nerve activity (SNA). Nerve traffic was averaged by coupling signal acquisition to electrocardiographic R waves. The amplitude of the averaged waveform was multiplied by the number of R waves sampled to provide a measure of SNA in arbitrary units. This was compared with SNA measured by manual digitization of hard-copy records. In nine volunteers, SNA was increased or decreased with stepwise infusions of nitroprusside or phenylephrine: there were 10 5-min periods of data in each subject. Across all subjects, the correlation between manual and signal-averaged measures of SNA was excellent during both nitroprusside (r = 0.98) and phenylephrine infusions (r = 0.91) and the slopes of the regression lines were near unity. In three periods of data collection, electrical artifacts were added randomly at frequencies of 0.5 and 0.07 Hz during playback of the signal into the computer. Signal-averaged estimates of SNA were unaffected by artifacts. This technique provides reliable observer-independent measures of SNA.

Blood Pressure↗

Continuous resetting of the human carotid baroreceptor-cardiac reflex.

Although human baroreflex responses have been studied during night as well as day, there has been no attempt to distinguish circadian changes of baroreflex function from those related to sleep. We measured carotid baroreceptor-cardiac reflex responses serially during a 24-h period in 11 normotensive volunteers who were awake and cooperative during testing. We applied sequences of ramped R-wave-triggered neck chamber pressure changes from +40 to -65 mmHg, during held expiration, at 3-h intervals. Subjects maintained their usual sleep-wake cycles but were awakened for three 30-min periods for night testing. There was no systematic change of baroreflex slope during the 24-h period. There were, however, parallel shifts of the entire sigmoid baroreceptor-cardiac reflex response relation along its R-R interval and arterial pressure axes associated with small, but significant, circadian changes of baseline R-R intervals and arterial pressures. Thus, although our data do not point toward major circadian variability of baro-reflex responsiveness, they provide evidence for an ongoing process of human baroreflex resetting.

Adult↗