PubMed HealthSearch

Biomedical subjects

C L Lucas

Publications and source records attributed to C L Lucas.

13 recordsLinked to original sources

Three-dimensional visualization of pulmonary blood flow velocity profiles in lambs.

For a better understanding of the characteristics of blood flow in the pulmonary artery, we constructed three-dimensional images of velocity profiles of blood flow in the pulmonary artery from pulsed Doppler ultrasound recordings in 14 lambs aged 28-40 days. In 8 lambs, pulmonary hypertension was created by the central venous injection of monocrotaline pyrrole. Six lambs served as unaltered controls. The velocity data were sampled in 2 mm increments along both an anterior-posterior axis and a right-left orthogonal axis in the main pulmonary artery. Using a computer-generated cross-sectional velocity matrix consisting of 0.25 mm square grids, the velocity of blood flow was estimated at each intersection. The cross-sectional velocity matrices were generated at 5 msec intervals during the entire cardiac cycle. In all animals, significant velocity reversal was detected near the posterior wall. In 7 of 14 animals, the peak forward velocity was located near the posterior wall. Three of 8 hypertensive models showed reacceleration during the mid-systolic phase at the center of the velocity waveform, but one reacceleration disappeared at a point only 2 mm away from the center of the vessel toward the posterior wall. Acceleration time correlated well with the mean pulmonary arterial pressure (PAP) (r = -0.85) and the log10 PAP (r = -0.86). Corrected acceleration time (acceleration time divided by the square root of the cardiac cycle length) also correlated with PAP (r = -0.78) and the log10 PAP (r = -0.81).

Animals

Intraluminal pulsed Doppler evaluation of the pulmonary artery velocity time curve in a canine model of acute pulmonary hypertension.

The velocity pattern of the blood flow in the pulmonary artery was investigated in an animal model of acute pulmonary hypertension. Nine anesthetized, open-chest dogs were embolized with polystyrene microspheres, and the velocity pattern of the blood flow in the pulmonary artery was studied with use of an invasive pulsed Doppler technique. Phasic intraluminal velocity was recorded with use of a miniature piezoelectric crystal activated by 20-MHz Doppler pulses and mounted on the tip of a needle probe introduced into the pulmonary artery. The recorded Doppler quadrature signals were processed by spectral analysis. Significant increases occurred in mean, systolic, and diastolic pulmonary arterial pressures (p less than 0.0002), in pulmonary vascular resistance (p less than 0.005), and in negative velocity time (duration in milliseconds that the mean velocity was directed toward the pulmonic valve) (p less than 0.002). Significant decreases occurred in right ventricular ejection time (p less than 0.006) and in positive velocity time (duration in milliseconds that the mean velocity was directed away from the pulmonic valve) (p less than 0.005). A significant shortening in the time to peak velocity (acceleration time) was found (p less than 0.005). Second-order regression analyses demonstrated an inverse correlation between the ratio of positive velocity time to negative velocity time and the mean pulmonary artery pressure in all animals (r = 0.71). These findings should be compared with the velocity patterns of the blood flow in the pulmonary artery obtained under pulmonary hypertensive conditions due to various causes to facilitate interpretation and understanding of clinical investigations.

Animals

Pulmonary blood velocity profile variability in open-chest dogs: influence of acutely altered hemodynamic states on profiles, and influence of profiles on the accuracy of techniques for cardiac output determination.

Clinical investigations focused on finding characteristics of noninvasively obtained measurements of pulmonary blood velocity that can be used to quantitate pulmonary blood flow and/or pulmonary pressure have often yielded results whose imprecision has been attributed to flow pattern variability. To determine flow pattern variability in an in vivo animal model in varying hemodynamic states, main pulmonary artery blood velocity waveforms were recorded in 17 dogs at 2-mm intervals along an anterior to posterior wall-oriented axis using a 20-MHz pulsed Doppler needle probe. Control data were obtained before the animals were subjected to altered flow (atrial level shunts) and pressure (10% O2 inhalation) states. Instantaneous velocity profiles were computed throughout the cardiac cycle. Estimates of pulmonary blood flow were obtained assuming an elliptical model of the pulmonary artery which allowed computation of velocity at all points in the cross section, based on the measured values along the axis. Model-based estimates were compared to measured values and estimates obtained in the traditional fashion, i.e., the product of centerline velocity and cross-sectional area. Results clearly showed marked interanimal variability, even in control states. Reverse flow in the posterior half of the vessel, which tended to become more pronounced with increased pulmonary artery pressure, was observed during late systole and early diastole. Elevated pulmonary blood flow tended to increase the maximum velocities along the anterior wall relative to midline velocities. Neither estimate of cardiac output yielded consistently accurate results (r = 0.77 for model-based method, r = 0.80 for area times central velocity method). Findings of this study, which highlight the dependency of waveform characteristics on sampling site, the large degree of intersubject variability, and the need for large or multiple sample volumes for pulmonary blood flow determination, help clarify inconsistencies observed by clinicians and suggest that future work with animal models will facilitate a greater understanding of the determinants of human pulmonary velocity waveforms.

Animals

Continuous measurement of pulmonary blood flow using a retractable pulsed Doppler probe.

The feasibility of measuring pulmonary blood flow (PAQ) continuously using a removable, extraluminal 20 MHz pulsed Doppler probe, which has been used successfully to measure aortic blood flow, was assessed in seven anesthetized mongrel dogs. Simultaneous recordings were made from the Doppler probe (range-gated 5-6 mm from the anterior wall of the main pulmonary artery) and an electromagnetic flow probe (encircling the aorta) over cardiac outputs (CO) ranging from 0.2 to 5.5 L/min. Assuming a flat velocity profile and a fixed cross-sectional area, PAQ was initially calculated as the product of area and mean velocity. Regression analyses (PAQ = a + b X CO) indicated good intraanimal linear correlations in six animals (r greater than or equal to 0.84) and no correlation in one animal (r = 0.003); however, PAQ was consistently higher than CO and interanimal variability was marked, as suggested by large deviations in mean intercept and slope values (a = 1.67 +/- 1.09 L/min and b = 0.70 +/- 0.33). Results improved (r greater than or equal to 0.79 in all animals, a = 0.47 +/- 0.52 L/min, and b = 0.77 +/- 0.21) when the method to estimate PAQ was altered to assume that the starting cross-sectional area was the area that would make baseline PAQ and CO agree, and that the area during each subsequent CO level changed as a function of pulmonary artery pressure and an estimate of pulmonary artery compliance. Results of this study imply that it will be more difficult to use this Doppler probe to monitor CO from the pulmonary artery than it was from the aorta due to the elliptical, more compliant pulmonary vessel walls and the irregular pulmonary artery velocity profile.

Animals

Constant postoperative monitoring of cardiac output after correction of congenital heart defects.

A new method has been developed that permits constant postoperative monitoring of mean and phasic cardiac output in patients after correction of congenital heart defects. A miniature ultrasound probe is attached to the adventitia of the ascending aorta at the conclusion of the operative procedure. This is connected to the monitoring equipment by means of polyurethane-covered wires that exit the chest wall through a small stab wound. The probe can easily be removed by gentle traction when the patient's condition is stable. The technique was developed, validated, and refined in extensive animal studies, and this report describes the first series of 20 consecutive human implants, performed between August 1984 and September 1985, in which the absolute cardiac output determination obtained with the ultrasound probe at the time of its application was correlated with cardiac output as measured with a standard electromagnetic flow probe. Fourteen male and six female patients (mean age 5.5 years) were studied. Operations performed included eight atrial septal defect repairs, four procedures for tetralogy of Fallot, three ventricular septal defect repairs, three stenotic valve corrections, and two Senning operations. One operative death occurred, but no complications were related to probe application or removal. The average cardiac output in the 20 patients as measured with the ultrasound probe was 2.2 +/- 1.1 L/min (range 0.67 to 5.27 L/min). This is nearly identical to the results noted with the electromagnetic flow probe, where the mean cardiac output was 2.3 +/- 1.2 L/min (range 0.7 to 6 L/min). Regression analysis revealed a high linear correlation (r = 0.9) between the two techniques. A monitor can display the cardiac output trend with 1 minute updates, which greatly enhance management of intravenous drug therapy and volume administration. In conclusion, this new extraluminal removable probe allows virtually continuous monitoring of the postoperative cardiac output after correction of congenital heart defects and should become a standard technique in the postoperative care of these patients.

Adolescent

Characteristics of blood flow velocity in the hypertensive canine pulmonary artery.

Pulmonary artery blood flow velocity was measured in 15 dogs by a recently developed direct intraluminal pulsed Doppler technique. Changes in velocity characteristics under conditions of experimentally induced hypoxic pulmonary hypertension were observed. Experimental conditions (fractional inspired oxygen concentration = 0.10) produced significant increases in mean pulmonary artery pressure and pulmonary vascular resistance. Overall and maximal negative velocity increased with pulmonary hypertension. Negative velocity occurred predominantly in the posterior half of the pulmonary artery during both control and experimental conditions. With pulmonary hypertension, diastolic negative velocity increased only in the posterior half of the pulmonary artery and systolic negative velocity decreased only in the anterior half. More basic knowledge of pulmonary artery blood flow characteristics may facilitate an informed approach to noninvasive detection of pulmonary hypertension. Direct measurements by this recently developed intraluminal technique will be useful in studying various conditions with altered pulmonary blood flow.

Animals

Contrasting pulmonary blood flow profiles in children with atrial and ventricular septal defects.

Instantaneous pulmonary blood flow profiles and other measures of haemodynamic functioning were studied in children with atrial septal defects (ASD) and children with ventricular septal defects (VSD) and normal pulmonary pressures and resistance at the time of defect closure. Though most parameters measured were comparable in the patient populations, several significant differences were found in the shape of the flow profile.

Blood Flow Velocity

Analysis of T cell receptor-gene rearrangement in T cells from the cerebrospinal fluid of patients with multiple sclerosis.

Characterization of T cells present in the cerebrospinal fluid (CSF) of patients with multiple sclerosis (MS) may contribute to an understanding of the immunopathologic role of these cells. To analyze the T cells in the CSF of MS patients, 30 cloned T cell lines from each of two MS patients were surveyed for their patterns of T cell receptor (TcR) beta-chain gene rearrangement. DNA from the (CSF-derived) T cell clones was digested with a number of restriction endonucleases and the gene rearrangement patterns were analyzed with a T cell receptor beta-chain probe. Southern blot analysis of the DNA of these T cell clones indicated that all had rearrangements of the TcR beta-chain genes, but none of the rearrangements were identical. These results suggest that, if a few clones of specific T cells are involved, they must form a tiny minority in comparison to the total number of T cells in the CSF of MS patients.

Adult