Biomedical subjects
C L Witherell
Publications and source records attributed to C L Witherell.
Follow-up of radiofrequency catheter ablation in children: results in 100 consecutive patients.
OBJECTIVES: The purpose of this study was to determine the outcome of a group of closely followed-up pediatric patients who had undergone radiofrequency ablation for cardiac arrhythmias. BACKGROUND: Although radiofrequency ablation in children has been shown to be effective and safe in the short term, results of longer term follow-up of these children must be considered when determining the place of radiofrequency ablation in the management of pediatric arrhythmias. METHODS: One hundred children aged 2 months to 17 years underwent a total of 119 radiofrequency ablation procedures for cure of tachycardia. Follow-up clinical data, electrocardiograms and 24-h Holter monitors were obtained and analyzed. RESULTS: All patients were alive, and none were lost to follow-up after a mean follow-up of 21.5 months (range 6 to 50). Success at last follow-up included accessory pathways in 66 (89%) of 74 patients, atrioventricular (AV) node reentry in 15 (88%) of 17, intraatrial reentry in 2 (67%) of 3, atrial flutter in 3 (100%) of 3, atrial ectopic tachycardia in 2 (67%) of 3, junctional ectopic tachycardia in 1 (100%) of 1 and ventricular tachycardia in 2 (100%) of 2 (overall success, 90 [90%] of 100). All recurrences were observed within 6 months of ablation. Major and minor complications (7%) included chest burn (one patient), foot microembolus (two patients), hematoma without pulse loss (four patients), femoral arteriovenous fistula requiring repair (one patient) and transient Mobitz I AV block (one patient). Immediate success, recurrence and complication rates were similar in the > or = 12-year old versus the < 12-year old group. Echocardiograms, available in 109 (92%) of 119 patients, showed possible procedure-related abnormalities in 2 (mitral regurgitation in 1, tricuspid regurgitation in 1, both mild), with no aortic insufficiency after 30 left-sided ablations performed by the retrograde approach. Follow-up Holter monitors, available in 77 (77%) of 100 patients, showed possible procedure-related abnormalities in 5 (frequent atrial ectopic tachycardia in 2, atrial flutter in 1, accelerated ventricular rhythm in 2). There were no early or late deaths. CONCLUSIONS: In children, the risks of radiofrequency ablation are low at follow-up evaluation. Longer-term follow-up of children undergoing radiofrequency ablation will be necessary to determine whether coronary abnormalities or serious new arrhythmias will develop.
Cardiac rhythm control devices.
More than 110,000 men, women, and children receive permanent implanted pacemakers annually in the United States alone, and thousands more receive implantable cardioverter defibrillators; more still are treated for a brief period with temporary pacing in critical care settings. Because of the prevalence of rhythm disturbances and the growing use of devices as a means of therapy, critical care nurses may reasonably expect to care for patients receiving or already using such equipment. Knowledge of its function is a useful tool at the bedside. This article discusses basic attributes and behaviors of these devices and methods of diagnosing and dealing with the most commonly seen difficulties associated with them.
Pacemaker generator pseudomalfunction: an artifact of Holter monitoring.
Explore the source record for details and available documents.
Questions nurses ask about pacemakers. How they work--and what to do when they don't.
Explore the source record for details and available documents.