PubMed Health⌕ Search

Biomedical subjects

C Lüring

Publications and source records attributed to C Lüring.

At least 19 recordsLinked to original sources

Stability of anterior vertebral body screws after kyphoplasty augmentation. An experimental study to compare anterior vertebral body screw fixation in soft and cured kyphoplasty cement.

The goal of this cadaver study was to compare the stability of anterior vertebral body screws after implantation in soft or cured kyphoplasty cement. Anterior vertebral body screws were inserted in a total of 30 thoracolumbar vertebrae of ten different human specimens: ten screws were implanted in non-augmented vertebrae (group 1), ten screws were placed in soft cement (group 2), and ten screws were placed in cured cement (group 3). The screws were then tested for biomechanical axial pullout resistance. Mean axial pullout strength was 192 N (range: 10-430 N) in group 1, 364 N (range: 65-875 N) in group 2, and 271 N (range: 35-625 N) in group 3. The paired Student's t-test demonstrated a significant difference between pullout strength of groups 1 and 2 (p= 0.0475). No significant difference was seen between pullout strength of groups 1 and 3 (p= 0.2646) and between groups 2 and 3 (p= 0.3863). We achieved a 1.9 times higher pullout strength with kyphoplasty augmentation of osteoporotic vertebrae compared with the pullout strength of non-augmented vertebrae. Implantation of anterior vertebral body screws in cured cement is a satisfactory method. With this method we found a 1.4 times higher pullout strength than non-augmented vertebrae.

Bone Cements↗

[Advances in soft tissue management in total knee arthroplasty. The use of imageless navigation systems].

Computer aided surgery has become established in the clinical routine over the past years. There are some very good studies which show that navigation optimizes reconstruction of the leg axis in total knee replacement. The question of why outliers occur in spite of navigation has to be asked. It is clear that total knee replacement is not only a bony procedure, but the soft tissues have an immense influence on postoperative stability of the prosthesis over the full range of movement. Current navigation systems allow visualization of the leg axis and size of the extension and flexion gap, and support the surgeon during soft tissue management. The current paper shows how the anatomic approach and the position of the patella influence soft tissue tension and support the surgeon during release of soft tissues in severe leg axis deformities.

Arthroplasty, Replacement, Knee↗

[Revision prosthetic of the knee joint. The influence of a navigation system on the alignment and reconstruction of the joint line].

Recognizing the rising number of primary total knee arthroplasties (TKA) over the last decade, one may assume an increasing number for revisions after a certain time delay. Studies showing a rate of only 78% satisfied patients provide a hint that there is still room for improvement. Therefore, it seemed worthwhile to evaluate the benefits of the computer assisted technique in revision TKA and compare the alignment results with the conventional technique. In a prospective study, 120 patients were operated for revision TKA using either the Vector-Vision navigation system (n=60) or the conventional technique (n=60). The axial limb alignment was evaluated on standardized pre- and postoperative full length weight-bearing radiographs and the variation of the joint line was determined by the method of Figgie from 1986.A precise reconstruction of the mechanical limb axis was achieved in 57/60 Patients (95%) in the computer assisted group and in 48/60 (80%) in the conventional group. A reconstruction of the joint line with a variation of less then 4 mm was achieved in 47/60 (78%) in the computer assisted and in 33/60 (55%) in the conventional group. Revision TKA remains a challenging procedure for the surgeon. Modern navigation systems offer additional information intraoperatively and might therefore simplify the procedure. In particular, the adjustment of the extension and flexion gap and the reconstruction of the joint line the results were superior. Furthermore, the use of a CT-free navigation system provides a significant improvement of prosthesis and leg alignment in revision TKA.

Aged↗

[Are computer assisted total knee replacements more accurately placed? A meta-analysis of comparative studies].

Computer-assisted surgery (CAS) has become established in many hospitals throughout the world, especially in the form of computer navigation for total knee replacement (TKR). Analysis of the studies available revealed 18 comparative studies examining the precision of implantation of knee endoprostheses following CAS and after implantation by the conventional technique. In a meta-analysis of 13 studies in which the same safe zone of +/-3 from neutral alignment was defined for the leg axis, a total of 1,784 TKR were performed. In the group of patients in whom the conventional technique was used, 75.6% (654/865) of TKR were implanted within the safe zone. In the CAS group 93.9% (863/919) of the prostheses were implanted within the safe zone (p<0.0001). The differences between the groups were statistically significant in 11 of the 13 studies, and the difference between groups for the entire patient population is highly significant. Only limited clinical results were ascertained in these comparative studies; there were no great differences between the treatment groups in clinical course.

Arthroplasty, Replacement, Knee↗

[Prevention of deep vein thrombosis in total knee replacement--current status of therapy in orthopedie and trauma departments in Germany].

INTRODUCTION: Symptomatic deep vein thrombosis is a serious complication after total knee arthroplasty, with a risk of about 4-5% despite prevention with herparin. Aim of the current study was to find out about the actual status of thrombosis prophylaxis in Germany after total knee replacement. MATERIAL AND METHODS: In a countrywide survey 470 German trauma and orthopaedic surgery departments were asked about their prophylactic procedures addressing deep vein thrombosis after total knee replacement. RESULTS: 98% perform prevention of thrombosis with low-molecular-weight heparin, 2% use unfractioned heparin. Low-molecular-weight heparin is applicated in standard doses in 48% and in 44% according to patient's weight. In 82% the prophylaxis is begun the night before surgery. The therapy is carried out for 4.7 weeks in mean. 96% use graduated compressions stocking as additional therapeutic option. CONCLUSION: Our survey shows that most of the surgeons perform prevention of deep vein thrombosis according to the official guidelines.

Arthroplasty, Replacement, Hip↗

Computer assistance in total knee replacement - a critical assessment of current health care technology.

The last five years have seen the rapid development of computer assisted surgery (CAS) in total knee replacement (TKR). Many surgeons perform TKR using navigation systems, which offer user-friendly workflows and reproducible results. A number of level 1 and 2 studies, according to evidence-based medicine criteria, have demonstrated that navigation in TKR allows a more precise implantation of the prosthesis, though CAS still requires an experienced surgeon and is time consuming. Nevertheless, 30% of surgeons in Germany who perform TKR have used navigation. It is still not known whether this new technique improves the longevity of TKR, however, and we therefore performed a meta-analysis to assess the results of this new health care technology.

Arthroplasty, Replacement, Knee↗

[What is the influence of the approach to intraoperative measurement of the knee joint on total knee arthroplasty? A navigation-controlled study on a cadaver knee].

Correct postoperative leg alignment and stability of the total knee prosthesis over the full range of movement is one critical factor for successful TKA. The anatomic approach is still the subject of controversy. The aim of our study was to elucidate the influence of the surgical approach on the ligament balancing and the anterioposterior limb axis.On five cadaver knees we studied the influence of the subvastus, midvastus, medial parapatellar, rectus snip, and tuberosity osteotomy approaches on the anterioposterior leg axis in extension and the rotation of the femoral component in flexion. Measurements were performed and documented by CT-free Ci-Navigation-System. Ligament tension was measured with a tensor device. We found that the subvastus approach leads to less widening of the medial compartment than all other approaches in extension. In 90 degrees flexion we found a similar influence. The consecutive release from subvastus to midvastus to medial parapatellar approach leads to a further opening of 0.5-1 degrees valgus in extension as well as in flexion. An everted patella amplifies this influence. The surgeon has to be aware of the impact on the ligament situation in regard to the anatomic approach when ligament balancing and soft tissue releases are carried out. Patella eversion should be avoided when managing soft tissues.

Arthroplasty, Replacement, Knee↗

[Soft tissue management in knees with varus deformity. Computer-assisted sequential medial ligament release].

BACKGROUND: Knees with severe varus deformities and contractures of the medial and lateral collateral ligaments and the posterior capsule require special soft tissue management to gain a stable knee over the full range of movement. The introduction of navigation systems into knee surgery has now made precise measurement of the leg axis and gap size possible. METHODS: Ten knee joints received a computer-assisted total knee replacement (Ci navigation system DePuy) I-Orthopaedics, Munich). The change of the leg axis and the size of the mediolateral gaps were measured and documented when performing a standardized medial ligament release sequence. RESULTS: We found a significant effect after each release step regarding the change of the leg axis as well as the gap width (p<0.001). The highest effect was seen for the 6-cm capsule release in extension and the release of the medial collateral ligament in 90 degrees flexion. CONCLUSION: Implementation of computer-assisted navigation facilitates visualization and quantification of the effect of the sequential medial soft tissue release in total knee arthroplasty.

Arthroplasty, Replacement, Knee↗

Intraoperative cutting errors in total knee arthroplasty.

INTRODUCTION: Precise reconstruction of leg alignment offers the best opportunity for achieving good long-term results in total knee arthroplasty (TKA). It was the aim of this study to evaluate the bone-cutting process as a potential source of inaccuracy in TKA. MATERIALS AND METHODS: In a consecutive series of 50 computer-assisted TKAs, cutting errors, which were defined as a difference between the cutting block position before sawing and the achieved resection plane afterwards, were measured for the distal femur and proximal tibia resection. Measurements were performed using a CT-based navigation system. RESULTS: For the distal femoral cut, there was a mean varus/valgus deviation of 0.6 degrees (SD+/-0.5 degrees ) and a mean flexion/extension deviation of 1.4 degrees (SD+/-1.3 degrees ). For the proximal tibia, varus/valgus alignment showed a mean deviation of 0.5 degrees (SD+/-0.5 degrees ). The mean sagittal variability was 1.0 degrees (SD+/-0.9 degrees ). Differences between the frontal and the sagittal plane were significant. CONCLUSION: To minimize cutting errors, techniques and instruments are needed which enable a more stable fixation of the cutting blocks or even more appropriate preparation instruments. Using a computer-assisted technique, the surgeon is aware of cutting errors occurring at each point of the operation and will therefore be able to correct these errors during surgery, while he is not aware of those errors with the conventional TKA technique.

Adult↗

Flexion gap configuration in total knee arthroplasty following high tibial osteotomy.

Previous reports have described the potentially compromising effect of a high tibial osteotomy (HTO) on the results of a subsequent total knee arthroplasty (TKA). Although the reasons are not clear, some authors reported problems in soft-tissue balancing. In a prospective study, 22 patients with an average interval of 5.8 years after closed-wedge HTO were operated for TKA. All operations were performed with a CT-free navigation system, and measurements of the extension and flexion gap were assessed. The intraoperative data were compared to a control group of 100 consecutive computer-assisted TKA without previous osteotomy. In the study group, a highly significant shift towards a medial opening of the flexion gap between the posterior condylar line and the tibial resection (study group 0.4+/-4.7 degrees medial opening versus control group 3.4+/-3.3 degrees lateral opening, p<0.001) was observed. In the study group, 10/22 showed a medial opening of the flexion gap compared to 11/100 in the control group. Surgeons should be aware of difficulties in soft-tissue balance in TKA following HTO, especially for the flexion gap configuration and the axial rotation of the femoral component.

Aged↗

Minimally invasive unicompartmental knee replacement with a nonimage-based navigation system.

In a prospective study, two groups of 20 unicompartmental knee replacements (UKR) each were operated either using a CT-free navigation system or the conventional minimal invasive technique. Radiographic assessment of postoperative alignment was performed by long-leg coronal and lateral radiographs. The results revealed a significant difference between the two groups in favor of navigation. In the computer-assisted group, 95% of UKRs were in a range of 4-0 degrees varus (mechanical axis) compared with 70% in the conventional group. The only inconvenience was a prolonged operation time (+19 min). Due to the limited exposure, the navigation system is helpful in achieving a more precise component orientation. The danger of overcorrection is diminished by real-time information about the leg axis at each step during the operation.

Aged↗

Radiological results of image-based and non-image-based computer-assisted total knee arthroplasty.

Restoration of the mechanical limb axis and accurate component orientation are two major factors affecting the long-term results after total knee replacement (TKR). Different navigation systems are available to improve the outcome. Image-based systems require pre-operative CT scans, while non-image-based systems gain all necessary information intra-operatively during a registration process. We studied 130 patients who received a TKR either using the CT-based (Knee 1.1) or the CT-free module (CT-free Knee 1.0) of the BrainLAB Vector-Vision Navigation System. Post-operative leg alignment and component orientation was determined on long-leg coronal and lateral X-rays. Sixty of 65 patients in the CT-based group and 63/65 patients in the CT-free group had a post-operative leg axis between 3 degrees varus/valgus. No significant differences were found for varus/valgus orientation of the femoral and tibial components.

Aged↗

[Navigated implantation of total knee endoprostheses in secondary knee osteoarthritis of rheumatoid arthritis patients as compared to conventional technique].

INTRODUCTION: The operative treatment of a secondary gonarthrosis due to RA claims high quality in soft tissue balancing and accurate alignment in total knee arthroplasty (TKA) which are essential for good long-term results. The efficiency of an imageless computer-assisted implantation in TKA was evaluated and compared with conventional technique. METHOD: The authors implanted each 40 TKA either using the imageless computer-assisted or classical surgeon-controlled technique. The quality of implantation was studied on postoperative long leg coronal and lateral x-rays. RESULTS: A postoperative leg axis between 3 degrees varus and 3 degrees valgus was obtained in 37 patients (92.5%) in the study group and 30 patients (75%) in the control group. Complications influencing the clinical outcome did not occur. CONCLUSION: The use of the imageless Vector-Vision navigation system provides the patient a good chance for longterm survival. Especially the ligament balancing tool appears to be useful. Cutting errors can be detected and intraoperatively corrected.

Arthritis, Rheumatoid↗

[Reconstruction of insufficient anterior cruciate ligament].

AIM: Reconstruction of insufficient anterior cruciate ligament (ACL) has become a standard operative procedure. Still, graft choice and fixation technique are discussed controversially. The objective of this study was to ascertain the current treatment of ACL reconstruction in german orthopedic surgery and trauma centers. METHODS: A total of 250 trauma and 220 orthopedic surgery centers were asked for their treatment strategy and postoperative procedure of ACL reconstruction in an anonymous German-wide survey. RESULTS: 230 questionnaires (48.9 %) were returned for evaluation. 90.4 % of the surgeons reconstruct the anterior cruciate ligament. Patellar tendon is used by 73 % of orthopedists and 80.7 % of trauma surgeons. Reconstruction with semitendinosus tendon transplant is performed by 71.6 % of the orthopedists and 41.6 % of trauma surgeons. For tibial fixation the interference screw is as well of the semitendinosus tendon as of the patellar tendon the most common technique. In about 30 % each the femoral fixation results from interference screw and endo-button. CONCLUSION: There is still no generally accepted intra- and postoperative strategy for reconstruction of ACL. Reconstruction with semitendinosus tendon becomes more common.

Analgesics↗

Alignment in total knee arthroplasty. A comparison of computer-assisted surgery with the conventional technique.

Restoration of neutral alignment of the leg is an important factor affecting the long-term results of total knee arthroplasty (TKA). Recent developments in computer-assisted surgery have focused on systems for improving TKA. In a prospective study two groups of 80 patients undergoing TKA had operations using either a computer-assisted navigation system or a conventional technique. Alignment of the leg and the orientation of components were determined on post-operative long-leg coronal and lateral films. The mechanical axis of the leg was significantly better in the computer-assisted group (96%, within +/- 3 degrees varus/valgus) compared with the conventional group (78%, within +/- 3 degrees varus/valgus). The coronal alignment of the femoral component was also more accurate in the computer-assisted group. Computer-assisted TKA gives a better correction of alignment of the leg and orientation of the components compared with the conventional technique. Potential benefits in the long-term outcome and functional improvement require further investigation.

Adult↗

[CT-based and CT-free navigation in knee prosthesis implantation. Results of a prospective study].

INTRODUCTION: Accurate leg alignment is one important factor for long-term survival in total knee arthroplasty (TKA). The classical surgeon-controlled technique is associated with a deviation of the leg axis of more than 3 degrees in up to 30% of cases, regardless of the surgeon's experience. The aim of this study was to test the efficiency of a CT-based and CT-free navigation system in restoration of the leg axis. METHOD: 100 TKA (PFC-Sigma, DePuy) were implanted either using the CT-based or CT-free module of the Vector-Vision navigation System (BrainLAB). There were no significant differences between the groups in preoperative leg deformity. Accuracy of implantation was determined on postoperative long-leg coronal and lateral X-rays. RESULTS: A postoperative leg axis between 3 degrees varus and 3 degrees valgus was obtained in 46 patients (92%) in the CT-based group (A) and in 48 patients (96%) in the CT-free group (B). No significant differences were found for varus / valgus orientation (+/-3 degrees ) of the femoral (A=96%; B=94%) and tibial (A and B each 98%) components. CONCLUSION: The use of the CT-based and CT-free Vector-Vision system allows a significant improvement in the accuracy of implantation in TKA. The CT-based module has the advantage of precise preoperative planning. On the other hand there are additional costs and time-consuming logistics. The advantages of the CT-free module are the intraoperative visualisation of the leg axis, the ligament balancing and joint kinematics. Cutting errors can be detected and corrected with both modules.

Adult↗