PubMed Health⌕ Search

Biomedical subjects

C Langer

Publications and source records attributed to C Langer.

At least 19 recordsLinked to original sources

An oncogenetic tree model in gastrointestinal stromal tumours (GISTs) identifies different pathways of cytogenetic evolution with prognostic implications.

To model the cytogenetic evolution in gastrointestinal stromal tumour (GIST), an oncogenetic tree model was reconstructed using comparative genomic hybridization data from 203 primary GISTs (116 gastric and 87 intestinal GISTs, including 151 newly analysed cases), with follow-up available in 173 cases (mean 40 months; maximum 133 months). The oncogenetic tree model identified three major cytogenetic pathways: one initiated by -14q, one by -1p, and another by -22q. The -14q pathway mainly characterized gastric tumours with predominantly stable karyotypes and more favourable clinical course. On the other hand, the -1p pathway was more characteristic of intestinal GISTs, with an increased capacity for cytogenetic complexity and more aggressive clinical course. Loss of 22q, more closely associated with -1p than -14q, appeared to initiate the critical transition to an unfavourable cytogenetic subpathway. This -22q pathway included accumulation of +8q, -9p, and -9q, which could all predict disease-free survival in addition to tumour site. Thus, insights into the cytogenetic evolution obtained from oncogenetic tree models may eventually help to gain a better understanding of the heterogeneous site-dependent biological behaviour of GISTs.

Chromosome Aberrations↗

Experimental purification of two-atom entanglement.

Entanglement is a necessary resource for quantum applications--entanglement established between quantum systems at different locations enables private communication and quantum teleportation, and facilitates quantum information processing. Distributed entanglement is established by preparing an entangled pair of quantum particles in one location, and transporting one member of the pair to another location. However, decoherence during transport reduces the quality (fidelity) of the entanglement. A protocol to achieve entanglement 'purification' has been proposed to improve the fidelity after transport. This protocol uses separate quantum operations at each location and classical communication to distil high-fidelity entangled pairs from lower-fidelity pairs. Proof-of-principle experiments distilling entangled photon pairs have been carried out. However, these experiments obtained distilled pairs with a low probability of success and required destruction of the entangled pairs, rendering them unavailable for further processing. Here we report efficient and non-destructive entanglement purification with atomic quantum bits. Two noisy entangled pairs were created and distilled into one higher-fidelity pair available for further use. Success probabilities were above 35 per cent. The many applications of entanglement purification make it one of the most important techniques in quantum information processing.

Journal Article↗

Microfabricated surface-electrode ion trap for scalable quantum information processing.

Individual laser-cooled 24Mg+ ions are confined in a linear Paul trap with a novel geometry where gold electrodes are located in a single plane and the ions are trapped 40 microm above this plane. The relatively simple trap design and fabrication procedure are important for large-scale quantum information processing (QIP) using ions. Measured ion motional frequencies are compared to simulations. Measurements of ion recooling after cooling is temporarily suspended yield a heating rate of approximately 5 motional quanta per millisecond for a trap frequency of 2.83 MHz, sufficiently low to be useful for QIP.

Journal Article↗

[Treatment of abdominal wall defects, including abdominal relaxation].

Abdominal wall defects that are amenable to direct fascial approximation are the indication for retromuscular mesh augmentation. Larger defects can be bridged with meshes used as abdominal wall substitution or with reconstructive flaps. Other options are indirect techniques to achieve primary preparation of the abdominal wall, either by mobilization of the abdominal wall muscles with the component separation method or by preoperative expansion of the abdominal cavity using a progressive pneumoperitoneum. Surgical repair of iatrogenic abdominal wall relaxations should combine plastic reconstruction with preperitoneal mesh implantation. Scientific evidence supporting any treatment option is weak, because few prospective, randomized trial data are available owing to the inhomogeneity of the patient population. Treatment of abdominal wall defects must therefore be proposed on an individual basis utilizing one or a combination of the techniques described.

Abdominal Wall↗

Creation of a six-atom 'Schrödinger cat' state.

Among the classes of highly entangled states of multiple quantum systems, the so-called 'Schrödinger cat' states are particularly useful. Cat states are equal superpositions of two maximally different quantum states. They are a fundamental resource in fault-tolerant quantum computing and quantum communication, where they can enable protocols such as open-destination teleportation and secret sharing. They play a role in fundamental tests of quantum mechanics and enable improved signal-to-noise ratios in interferometry. Cat states are very sensitive to decoherence, and as a result their preparation is challenging and can serve as a demonstration of good quantum control. Here we report the creation of cat states of up to six atomic qubits. Each qubit's state space is defined by two hyperfine ground states of a beryllium ion; the cat state corresponds to an entangled equal superposition of all the atoms in one hyperfine state and all atoms in the other hyperfine state. In our experiments, the cat states are prepared in a three-step process, irrespective of the number of entangled atoms. Together with entangled states of a different class created in Innsbruck, this work represents the current state-of-the-art for large entangled states in any qubit system.

Journal Article↗

Long-lived qubit memory using atomic ions.

We demonstrate experimentally a robust quantum memory using a magnetic-field-independent hyperfine transition in 9Be+ atomic ion qubits at a magnetic field B approximately = 0.01194 T. We observe that the single physical qubit memory coherence time is greater than 10 s, an improvement of approximately 5 orders of magnitude from previous experiments with 9Be+. We also observe long coherence times of decoherence-free subspace logical qubits comprising two entangled physical qubits and discuss the merits of each type of qubit.

Journal Article↗

Spectroscopy using quantum logic.

We present a general technique for precision spectroscopy of atoms that lack suitable transitions for efficient laser cooling, internal state preparation, and detection. In our implementation with trapped atomic ions, an auxiliary "logic" ion provides sympathetic laser cooling, state initialization, and detection for a simultaneously trapped "spectroscopy" ion. Detection is achieved by applying a mapping operation to each ion, which results in a coherent transfer of the spectroscopy ion's internal state onto the logic ion, where it is then measured with high efficiency. Experimental realization, by using 9Be+ as the logic ion and 27Al+ as the spectroscopy ion, indicates the feasibility of applying this technique to make accurate optical clocks based on single ions.

Journal Article↗

Hyperfine coherence in the presence of spontaneous photon scattering.

The coherence of a hyperfine-state superposition of a trapped 9Be+ ion in the presence of off-resonant light is studied experimentally. It is shown that Rayleigh elastic scattering of photons that does not change state populations also does not affect coherence. We observe coherence times that exceed the average scattering time of 19 photons which is determined from measured Stark shifts. This result implies that, with sufficient control over its parameters, laser light can be used to manipulate hyperfine-state superpositions with very little decoherence.

Journal Article↗

Implementation of the semiclassical quantum Fourier transform in a scalable system.

We report the implementation of the semiclassical quantum Fourier transform in a system of three beryllium ion qubits (two-level quantum systems) confined in a segmented multizone trap. The quantum Fourier transform is the crucial final step in Shor's algorithm, and it acts on a register of qubits to determine the periodicity of the quantum state's amplitudes. Because only probability amplitudes are required for this task, a more efficient semiclassical version can be used, for which only single-qubit operations conditioned on measurement outcomes are required. We apply the transform to several input states of different periodicities; the results enable the location of peaks corresponding to the original periods. This demonstration incorporates the key elements of a scalable ion-trap architecture, suggesting the future capability of applying the quantum Fourier transform to a large number of qubits as required for a useful quantum factoring algorithm.

Journal Article↗

Enhanced quantum state detection efficiency through quantum information processing.

We investigate theoretically and experimentally how quantum state-detection efficiency is improved by the use of quantum information processing (QIP). Experimentally, we encode the state of one 9Be(+) ion qubit with one additional ancilla qubit. By measuring both qubits, we reduce the state-detection error in the presence of noise. The deviation from the theoretically allowed reduction is due to infidelities of the QIP operations. Applying this general scheme to more ancilla qubits suggests that error in the individual qubit measurements need not be a limit to scalable quantum computation.

Journal Article↗

Randomized clinical trial comparing lightweight composite mesh with polyester or polypropylene mesh for incisional hernia repair.

BACKGROUND: Polymer mesh has been used to repair incisional hernias with lower recurrence rates than suture repair. A new generation of mesh has been developed with reduced polypropylene mass and increased pore size. The aim of this study was to compare standard mesh with new lightweight mesh in patients undergoing incisional hernia repair. METHODS: Patients were randomized to receive lightweight composite mesh, or standard polyester or polypropylene mesh. Outcomes were evaluated at 21 days, 4, 12 and 24 months from patient responses to the Short Form 36 (SF-36) and daily activity questionnaires. Complications and recurrence rates were recorded. RESULTS: A total of 165 patients were included in an intention-to-treat analysis (83 lightweight mesh, 82 standard mesh). Postoperative complication rates were similar. The overall hernia recurrence rate was 17 per cent with the lightweight mesh versus 7 per cent with the standard mesh (P = 0.052). There were no differences in SF-36 physical function scores or daily activities between 21 days and 24 months after surgery. CONCLUSION: The use of the lightweight composite mesh for incisional hernia repair had similar outcomes to polypropylene or polyester mesh with the exception of a non-significant trend towards increased hernia recurrence. The latter may be related to technical factors with regard to the specific placement and fixation requirements of lightweight composite mesh.

Activities of Daily Living↗

[Present treatment strategies for rectal carcinoma].

In the last ten years, considerable progress has been achieved in the treatment of rectal cancer. According to improved interdisciplinary staging, rectal carcinomas can be treated based on a stage-dependent concept: "low-risk" pT1 (G1/G2) carcinomas can be cured by local full wall excision, while "high-risk" pT1 (G3/G4) and pT2 carcinomas require transabdominal resection. In contrast, locally advanced rectal cancers in cUICC-II/-III stages (T3/T4 or N(+)) should receive long-term, 5-FU-based, neoadjuvant chemoradiotherapy according to the excellent results of the CAO/AIO/ARO-94 trial of the German Rectal Cancer Study Group. High-quality resection must be based on radical oncologic principles such as "no-touch" technique, radicular dissection of vessels, and total mesorectal excision. Multimodal treatment is completed with adjuvant 5-FU-based chemotherapy. This therapeutic approach led to a reduction in the 5-year local recurrence rate to 6% and disease-free survival of approximately 68% in advanced rectal cancer (overall survival: 76%).

Chemotherapy, Adjuvant↗

[In-vitro study of the cellular response of human fibroblasts cultured on alloplastic hernia meshes. Influence of mesh material and structure].

BACKGROUND: The biocompatibility of meshes in hernia surgery seems to be influenced markedly by the amount of the selected material and its structure. Fibroblasts play a major key role during the process of mesh incorporation. This study was performed to investigate differences in cell morphology and proliferation of human fibroblasts cultured on different polypropylene meshes. METHODS: In the present in vitro study the cellular response of human fibroblasts was investigated by scanning electron microscopy (SEM), comparing three different polypropylene meshes: a newly constructed low-weight and microporous mesh (NK1), a low-weight and macroporous mesh with absorbable polyglactin filaments (Vypro), and a heavy-weight and microporous mesh (BiomeshP1). Human fibroblasts (1,5.10(5) cells) were incubated with the meshes (each 12 mm(2)) for 6 hours, 5 days, 2, 4, 6, and 12 weeks. Computer-assisted morphometry of the fibroblast/mesh surface ratio served to reflect the biological cell response. RESULTS: The Vypro mesh showed the significantly highest fibroblast density during the first 6 weeks, but cell growth was nearly exclusively limited to the polyglactin filaments. At 3 months, after reabsorption of the polyglactin, the fibroblast-coated polypropylene mesh surface was only 50% compared to NK1 and BiomeshP1. The morphologic aspect of the fibroblasts on the BiomeshP1 mesh was much more degenerative and unphysiological, compared to NK1 and Vypro, with isolated, single cells instead of a broad, connective growth. The BiomeshP1 showed a significantly higher fibroblast proliferation around the nodes of the mesh compared to the straight filaments. On the NK1 mesh fibroblasts exclusively proliferated on the filaments but not on the pressed mesh surface. CONCLUSIONS: The polymer surface and structure appears to be of major importance for the biocompatibility of meshes: human fibroblasts preferably grow on low-weight meshes, thin filaments, and mesh nodes. Heavy-weight meshes induce degenerative cell reactions. Polyglactin seems to further improve cell proliferation whereas a pressed mesh surface without pores hinders fibroblast growth.

Cell Count↗

Gastrointestinal stromal tumor (GIST) -- single center experience of prolonged treatment with imatinib.

BACKGROUND: The tyrosine kinase inhibitor imatinib has been introduced into the treatment of gastrointestinal stromal tumors (GIST). Here we report our results of prolonged treatment in comparison to a similar group of GIST patients who had died before imatinib became available. METHODS: Fourteen patients with recurrent or metastatic GIST were treated with imatinib. Clinical data and tumor samples of ten patients from the pre-imatinib era were available for comparison. Comparative genomic hybridisation (CGH) was performed on tumors to identify changes that may predict response to treatment. RESULTS: Fourteen patients were treated, mean treatment time 22.3 months (1 non-response, 2 progression after initial response, 2 stable diseases, 8 partial responses, 1 complete response). Adverse side effects were mild in general. Survival was higher in the treated group (41.1 months vs. 34.8 months in the historical group). Eleven treated patients are alive. CGH analysis showed comparable numbers of chromosomal aberations in both groups. CONCLUSION: Prolonged treatment with imatinib is safe and effective in patients with recurrent or metastatic GIST.

Adult↗

Realization of quantum error correction.

Scalable quantum computation and communication require error control to protect quantum information against unavoidable noise. Quantum error correction protects information stored in two-level quantum systems (qubits) by rectifying errors with operations conditioned on the measurement outcomes. Error-correction protocols have been implemented in nuclear magnetic resonance experiments, but the inherent limitations of this technique prevent its application to quantum information processing. Here we experimentally demonstrate quantum error correction using three beryllium atomic-ion qubits confined to a linear, multi-zone trap. An encoded one-qubit state is protected against spin-flip errors by means of a three-qubit quantum error-correcting code. A primary ion qubit is prepared in an initial state, which is then encoded into an entangled state of three physical qubits (the primary and two ancilla qubits). Errors are induced simultaneously in all qubits at various rates. The encoded state is decoded back to the primary ion one-qubit state, making error information available on the ancilla ions, which are separated from the primary ion and measured. Finally, the primary qubit state is corrected on the basis of the ancillae measurement outcome. We verify error correction by comparing the corrected final state to the uncorrected state and to the initial state. In principle, the approach enables a quantum state to be maintained by means of repeated error correction, an important step towards scalable fault-tolerant quantum computation using trapped ions.

Journal Article↗