PubMed Health⌕ Search

Biomedical subjects

C Lartizien

Publications and source records attributed to C Lartizien.

3 recordsLinked to original sources

Assessment of non-reperfused and reperfused myocardial infarction using diffusible or deposited radiolabelled perfusion imaging agents.

PURPOSE: Incomplete microvascular reperfusion is often observed in patients undergoing thrombolytic therapy or angioplasty for acute myocardial infarction and has important prognostic implications. We compared the myocardial uptake of diffusible ((201)Tl) and deposited ((99m)TcN-NOET) perfusion imaging agents in the setting of experimental infarction. METHODS: Rats were subjected to permanent coronary occlusion (OCC, n=10) or to 45-min occlusion and reperfusion (REP, n=17). Seven days later, the tracers were co-injected and the animals were euthanised 15 min (all ten rats in the OCC group and 12 rats in the REP group) or 120 min (five rats from the REP group, euthanised at this time point to evaluate any redistribution of the tracers: REP-RED group) afterwards. Infarct size determination and (99m)TcN-NOET/(201)Tl ex vivo imaging were performed. Regional flow and tissue oedema were quantified using radioactive microspheres and (99m)Tc-DTPA, respectively. RESULTS: (99m)TcN-NOET and (201)Tl defect magnitudes were similar in OCC animals (0.11+/-0.01 vs 0.13+/-0.01). In REP animals, (201)Tl defect magnitude (0.25+/-0.02) was significantly lower than the magnitude of (99m)TcN-NOET and flow defects (0.14+/-0.03 and 0.17+/-0.01, respectively; p<0.05), despite the lack of (201)Tl redistribution (REP-RED animals). (99m)Tc-DTPA indicated the presence of oedema in the reperfused area. Blood distribution studies showed that, unlike (99m)TcN-NOET, (201)Tl plasma activity was mostly unbound to plasma proteins. CONCLUSION: (99m)TcN-NOET and (201)Tl delineated the non-viable area in chronic non-reperfused and reperfused myocardial infarction. The significantly decreased (201)Tl defect in reperfused infarction was likely due to partial diffusion of the tracer from the plasma into the oedema present in the infarcted area. Deposited perfusion tracers might be better suited than diffusible agents for the assessment of regional flow following reperfusion of myocardial infarction.

Animals↗

GATE: a simulation toolkit for PET and SPECT.

Monte Carlo simulation is an essential tool in emission tomography that can assist in the design of new medical imaging devices, the optimization of acquisition protocols and the development or assessment of image reconstruction algorithms and correction techniques. GATE, the Geant4 Application for Tomographic Emission, encapsulates the Geant4 libraries to achieve a modular, versatile, scripted simulation toolkit adapted to the field of nuclear medicine. In particular, GATE allows the description of time-dependent phenomena such as source or detector movement, and source decay kinetics. This feature makes it possible to simulate time curves under realistic acquisition conditions and to test dynamic reconstruction algorithms. This paper gives a detailed description of the design and development of GATE by the OpenGATE collaboration, whose continuing objective is to improve, document and validate GATE by simulating commercially available imaging systems for PET and SPECT. Large effort is also invested in the ability and the flexibility to model novel detection systems or systems still under design. A public release of GATE licensed under the GNU Lesser General Public License can be downloaded at http:/www-lphe.epfl.ch/GATE/. Two benchmarks developed for PET and SPECT to test the installation of GATE and to serve as a tutorial for the users are presented. Extensive validation of the GATE simulation platform has been started, comparing simulations and measurements on commercially available acquisition systems. References to those results are listed. The future prospects towards the gridification of GATE and its extension to other domains such as dosimetry are also discussed.

Computer Simulation↗

A hybrid scatter correction for 3D PET based on an estimation of the distribution of unscattered coincidences: implementation on the ECAT EXACT HR+.

We implemented a hybrid scatter-correction method for 3D PET that combines two scatter-correction methods in a complementary way. The implemented scheme uses a method based on the discrimination of the energy of events (the estimation of trues method (ETM)) and an auxiliary method (the single scatter simulation method (SSSI) or the convolution-subtraction method (CONV)) in an attempt to increase the accuracy of the correction over a wider range of acquisitions. The ETM takes into account the scatter from outside the field-of-view (FOV), which is not estimated with the auxiliary method. On the other hand, the auxiliary method accounts for events that have scattered with small angles, which have an energy that cannot be discriminated from that of unscattered events using the ETM. The ETM uses the data acquired in an upper energy window above the photopeak (550-650 keV) to obtain a noisy estimate of the unscattered events in the standard window (350-650 keV). Our implementation uses the auxiliary method to correct the residual scatter in the upper window. After appropriate scaling, the upper window data are subtracted from the total coincidences acquired in the standard window, resulting in the final scatter estimate, after smoothing. In this work we compare the hybrid method with the corrections used by default in the 2D and 3D modes of the ECAT EXACT HR+ using phantom measurements. Generally, the contrast was better with the hybrid method, although the relative errors of quantification were similar. We conclude that hybrid techniques such as the one implemented in this work can provide an accurate, general-purpose and practical way to correct the scatter in 3D PET, taking into account the scatter from outside the FOV.

Brain↗