Changes in bone density after cemented total knee arthroplasty: influence of stem design.

Total knee arthroplasty has shown excellent survivorship in short-term and intermediate-term studies. With longer follow-up, however, aseptic loosening becomes an increasing cause of failure. Dual-energy x-ray absorptiometry scanning has shown that stress shielding occurs from altered mechanical loading. The purpose of this study is to determine if tibial stem design affects bone density in the longterm. Bone densities in the proximal tibia with and without cemented stems were compared at an average of 94 months after surgery. The bone quality under the Miller-Galante I prosthesis, which has 4 0.5-cm pegs, was compared with the bone quality under a Press-Fit Condylar prosthesis with a single 4-cm stem. Each group was also compared with the unoperated contralateral tibia. Results showed that there is a significantly reduced density of bone in the tibial metaphysis in the cemented stemmed group but not in the pegged group. There were no changes distally in the diaphyseal bone. This study supports the contention that the use of a cemented stem reduces proximal stresses and may result in proximal bone resorption. Although the use of a stem provides excellent resistance to lift-off and shear, it comes at a price. The proximal resorption may contribute to the persistence of tibial component loosening as a primary threat to survivorship. This bone loss may complicate revision surgery. Consideration should be given to using shorter tibial stems, less cement, or alternative designs that avoid long-stem fixation.

Absorptiometry, Photon↗

Diabetic glomerulopathy may be preventable.

Variation in blood glucose levels throughout the day was assessed in six diabetic maintenance hemodialysis patients and six diabetic renal transplant recipients. None of the twelve studied patients had good control. Glucose levels greater than 300 mg/dl were noted in four of six dialysis patients and five of six transplant recipients. A regimen of self blood glucose measurement and multiple insulin doses was instituted for four transplant and three dialysis patients. Each patient achieved the desired glucose range of 60 to 120 mg/dl most of the time, with a resultant fall in mean hemoglobin A1c concentration from 10.3% to 7.9%. It is suggested that a long term trial of self glucose monitoring might prove beneficial to treated uremic diabetics.

Adult↗