PubMed Health⌕ Search

Biomedical subjects

C Luebbert

Publications and source records attributed to C Luebbert.

3 recordsLinked to original sources

Rapid determination of short DNA sequences by the use of MALDI-MS.

We have developed a protocol for rapid sequencing of short DNA stretches (15-20 nt) using MALDI-TOF-MS. The protocol is based on the Sanger concept with the modification that double-stranded template DNA is used and all four sequencing reactions are performed in one reaction vial. The sequencing products are separated and detected by MALDI-TOF-MS and the sequence is determined by comparing measured molecular mass differences to expected values. The protocol is optimized for low costs and broad applicability. One reaction typically includes 300 fmol template, 10 pmol primer and 200 pmol each nucleotide monomer. Neither the primer nor any of the nucleotide monomers are labeled. Solid phase purification, concentration and mass spectrometric sample preparation of the sequencing products are accomplished in a few minutes and parallel processing of 96 samples is possible. The mass spectrometric analyses and subsequent sequence read-out require only a few seconds per template.

Alleles↗

Prestructured MALDI-MS sample supports.

Prestructured MALDI-MS sample supports have been developed that simplify high-throughput analysis of biomolecules and improve the detection sensitivity. The mass spectrometric sample support is coated with a thin layer of hydrophobic Teflon that carries an array of 200-microm gold spots, which provide hydrophilic sample anchors. Each transferred sample droplet contacts one anchor, on top of which, after solvent evaporation, the sample is exclusively deposited due to the strongly water repellent nature of the Teflon surface. The initial matrix concentration is kept low, enabling sample up-concentration by more than 2 orders of magnitudes before crystallization commences. As a result, the detection sensitivity is improved as documented by mass spectra recorded from 100 amol of various peptides, 1 fmol of a DNA 20 mer, and 5 fmol of a 130 bp PCR product. Size and spacing of the hydrophilic anchors are optimized for MALDI-MS performance (sample spot size approximately = laser irradiation spot size), for short analysis times (predetermined sample coordinates), and for high throughput sample preparation (sample anchor array according to the 1536 microtiter plate format).

DNA↗

Improvements in protein identification by MALDI-TOF-MS peptide mapping.

A new strategy for identifying proteins in sequence data-bases by MALDI-MS peptide mapping is reported. The strategy corrects for systematic deviations of determined peptide molecular masses using information contained in the opened database and thereby renders unnecessary internal spectrum calibration. As a result, data acquisition is simplified and less error prone. Performance of the new strategy is demonstrated by identification of a set of recombinant, human cDNA expression products as well as native proteins isolated from crude mouse brain extracts by 2-D electrophoresis. Using one set of calibration constants for the mass spectrometric analyses, 20 proteins were identified without applying any molecular weight restrictions, which was not possible without data correction. A sequence database search program has been written that performs all necessary calculations automatically, access to which will be provided to the scientific community in the Internet.

Animals↗