PubMed Health⌕ Search

Biomedical subjects

C Lydon

Publications and source records attributed to C Lydon.

6 recordsLinked to original sources

Effect of elongation rate on the failure properties of the rabbit anterior cruciate ligament.

The effect of elongation rate on the failure properties of the rabbit femur-anterior crucicate ligament-tibia were investigated. Paired limbs were elongated to failure at rates of 0.0001 m s(-1) and 0.92 m s(-1). Two distinct types of tibial avulsion injury reflecting rate-dependent areas of weakness were noted. 'Bony avulsions' formed by the junction between cortical and trabecular bone comprised the predominant injury observed at the faster elongation rate. 'Fibrous avulsions' between the zones of mineralized fibrocartilage and bone occurred predominantly at the slower elongation rate. The faster rate significantly increased ultimate load (74%) and stiffness (615%) on average, relative to the slow rate. In contrast to what has been previously described, there was a significant decrease in failure deformation (79%) at the faster rate.

Journal Article↗

On the understanding of clinical instability.

STUDY DESIGN: Three-dimensional flexibility changes due to the application of an external fixator at C4-C5 were studied in cervical spine specimens. OBJECTIVES: To evaluate the biomechanical effects of applying a cervical external fixator to a patient using an in vitro model. SUMMARY OF BACKGROUND DATA: There is controversy regarding the relationship between the changes in spinal motion and clinical instability. METHODS: Using fresh cadaveric C4-C7 specimens, multidirectional flexibility was measured at all vertebral levels, before and after the fixator application at C4-C5, C5-C6, and C4-C6. RESULTS: The average ranges of motion for flexion, extension, lateral bending, and axial rotation were 8.3 degrees, 7.2 degrees, 5.3 degrees, and 5.6 degrees, which decreased by 40%, 27%, 32%, and 58%, respectively, because of the fixator application. The corresponding neutral zones were 3.4 degrees, 3.4 degrees, 3.0 degrees, and 2.0 degrees, which decreased by 76%, 76%, 54% and 69%, respectively. The decreases with the fixation at C4-C5 were similar to those for fixation at C5-C6. CONCLUSIONS: This in vitro study documented that the application of an external fixator to the cervical spine decreases the intervertebral motion in general, and decreases flexion, extension and torsional neutral zones in particular. The findings help explain the clinical instability of the spine and support the hypothesis that the neutral zone is more closely associated with the clinical instability than is the range of motion.

Adult↗

Anular incision technique on the strength and multidirectional flexibility of the healing intervertebral disc.

STUDY DESIGN: This study used a sheep model to biomechanically analyze the healing strength of the anulus fibrosus after two types of anular incisions. OBJECTIVE: This study evaluated whether the type of anular incision made at the time of lumbar discectomy plays a role in the subsequent healing strength of the anulus and the biomechanical flexibility of the corresponding motion segment. METHODS: Two types of anular incision, a full thickness removal of a box or window of anulus and a full thickness straight transverse slit through the anulus, were made in the intervertebral discs of 18 adult sheep. After healing times of 2, 4, and 6 weeks, the intervertebral discs were tested versus control levels for strength of anular healing and biomechanical flexibility of the corresponding motion segment. RESULTS: The box incised discs showed a significantly greater loss in strength during the early healing phase (2 to 4 weeks) and a longer response before recovering anular strength when compared with the slit-incised discs. The type of incision also affected the multidirectional flexibility of the motion segments in a differentiated manner. Larger amounts of motion were seen with the box incision when compared with the slit incision at all time periods and in all pure moments. CONCLUSION: The technique of anular incision plays a definite role in the timing and strength of subsequent anular healing. The box incision through the anulus led to significantly weaker healing than did the slit incision in the early healing phase (2-4 weeks). Also, larger amounts of motion were seen in the vertebral motion segments of those discs undergoing box incision when compared with slit or control levels.

Animals↗

[The unstable spine--an "in vitro" and "in vivo study" on better understanding of clinical instability].

In cases of suspected painful instability of a cervical segment, temporary external fixation by means of external fixator was applied. The segmental immobilization caused immediate relief of pain. The pain reoccurred after removal of the immobilization. The effect of immobilization by external fixation was investigated in biomechanical tests using fresh cadaveric C4-7 specimens. Multidirectional flexibility was measured before and after application of the fixator at C4/C5, C5/C6 and C4-6. We measured the reduction in motion between the different segments. In every situation the neutral zone decreased more than the range of motion. The findings are helpful to understand the clinical instability of the spine and support the hypothesis that the neutral zone is more closely associated with clinical instability than range of motion. The combination of clinical application and biomechanical investigation allowed us to establish a direct correlation between instability and pain.

Accidents, Traffic↗

Too slap happy.

Explore the source record for details and available documents.

Domestic Violence↗