PubMed Health⌕ Search

Biomedical subjects

C M Block

Publications and source records attributed to C M Block.

4 recordsLinked to original sources

Histologic evaluation of the LaminOss osteocompressive dental screw: a pilot study.

This animal study compared the response of canine mandibular bone using the orthopedic principle of osteocompression by the function of an immediately loaded dental implant vs an unloaded dental implant of the same design and size. Two dogs were partially edentulated in the mandible. A total of 8 osteocompressive screw implants, 2 per quadrant were placed and evaluated histomorphometrically after 3 days in 1 dog and after 3 months in the second dog. The second dog had a two-unit fixed bridge placed immediately postsurgically in occlusal function on the right side; on the left side, the implants were splinted out of occlusion as a control. Histologically, no bone necrosis was observed at the implant interface by any of the 8 implants for either period as a direct result of the 4-mm-diameter by 13-mm-length implant design. Clinical parameters did not differ among the implants; however, at 3 months, the immediately loaded implants demonstrated more than twice the amount of bone density at their surfaces compared to the unloaded implants of the same design. Future human clinical research would be necessary to provide a meaningful statistical analysis to validate the importance of this implant design and the function of osteocompression.

Animals↗

Effects of the Nd:YAG dental laser on plasma-sprayed and hydroxyapatite-coated titanium dental implants: surface alteration and attempted sterilization.

The Nd:YAG dental laser has been recommended for a number of applications, including the decontamination or sterilization of surfaces of dental implants that are diseased or failing. The effects of laser irradiation in vitro (1) on the surface properties of plasma-sprayed titanium and plasma-sprayed hydroxyapatite-coated titanium dental implants, and (2) on the potential to sterilize those surfaces after contamination with spores of Bacillus subtilis have been examined. Surface effects were examined by scanning electron microscopy, energy dispersive spectroscopy, and x-ray diffraction after laser irradiation at 0.3, 2.0, and 3.0 W using either contact or noncontact handpieces. Controls received no laser irradiation. Melting, loss of porosity, and other surface alterations were observed on both types of implants, even with the lowest power setting. For the sterilization study, both types of implants were first sterilized by exposure to ethylene oxide and then contaminated with spores of B subtilis. After laser irradiation, the implants were transferred to sterile growth medium and incubated. Laser irradiation did not sterilize either type of implant. The spore-contaminated implants in the control group were successfully sterilized with ethylene oxide.

Bacillus subtilis↗