Fixation of humeral prostheses and axial micromotion.

Surgeons often avoid cementing a proximal humeral prosthesis. Occasionally bony augmentation is needed. This study was undertaken to compare proximal cementation in combination with distal press with total cementation or press fit alone. In phase 1 axial micromotion with axial loading was measured in 15 pairs of humeri: 5 fully cemented versus proximally cemented, 5 fully cemented versus press fit, and 5 proximally cemented versus press fit. X-ray films of the specimens were obtained to assess canal fill. In phase 2 axial micromotion was measured in 5 pairs of high mineral density and 5 pairs of low mineral density to compare proximal cementation with press fit. The 3 M modular prosthesis was used in both phases. No difference was found in phase 1 among the 3 fixation techniques. A strong reverse statistical correlation (P = .007) (r = .55) was seen between axial micromotion and fill of the canal with the prosthesis. In the second phase no statistically significant difference was found between the techniques of fixation or between the 2 bone densities. Fill of the canal at the distal end of the prosthesis was the only variable found that affected axial micromotion, but it accounted for only approximately 30% of the variance. Bone quality and augmentation of the proximal bone with cement did not affect axial micromotion in this experiment but warrant further study.

Bone Cements↗

Fixation of proximal humeral prostheses and rotational micromotion.

Twenty pairs of cadaveric humeri were used to compare the rotational stability of proximal humeral prostheses fixed by proximal cementation with the stability offered by press fit or full cementation. For each proximally cemented specimen, only the upper portion of the prosthesis was coated with cement. For the fully cemented specimens, a cement restrictor was used just distal to the prosthesis, and a finger-packing technique was used to fill the proximal humeral medullary canal. Torque was applied to the Morse taper of the prostheses, and rotational micromotion was measured at the level of the osteotomy. In each of 11 pairs of cadaveric humeri, one side was press fit and the contralateral side was proximally cemented; in each of 9 pairs, proximal cementation was compared with full cementation. Proximally cemented prostheses' micromotion was significantly less than that of press-fit prostheses (P = .0016). There was no difference in micromotion between proximal cementation and full cementation (P = .82). Proximal cementation increased initial fixation over press fit. Full cementation did not increase rotational stability.

Arthroplasty↗