Removal of Heavy Metal and Halide Contamination from Macronutrient Salts.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to C M Johnson.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
OBJECTIVE: To determine on an ongoing basis the safety and efficacy of expanded polytetrafluoroethylene (Gore-Tex soft tissue patch and preformed nasal implants) as an implant in rhinoplasty. DESIGN: A retrospective study of 309 consecutive patients who underwent rhinoplasty, including augmentation with Gore-Tex, during a 10-year period. SETTING: Two major academic medical centers and 2 private office surgical centers. INTERVENTION: One hundred sixty-two patients (52%) presented for primary rhinoplasty; the remaining 147 (48%) presented for revision surgery. All received Gore-Tex implants to augment the nasal dorsum and/or base. The grafts ranged from 1 to 10 mm in thickness. Follow-up ranged from 5 months to 10 years, 5 months, with an average of 40.4 months. MAIN OUTCOME MEASURES: Clinically noted complications and patient satisfaction. RESULTS: Ten (3.2%) of 309 grafts became infected and were removed. One graft was removed and 1 graft was modified and replaced postoperatively because of excessive augmentation. Infection requiring removal occurred in 8 patients (5.4%) undergoing revision rhinoplasty and in 2 patients (1.2%) undergoing primary rhinoplasty. Nasal septal perforation was present preoperatively in 3 of the patients who developed infection requiring removal, and we consider it a contraindication for nasal Gore-Tex implantation. CONCLUSIONS: Gore-Tex remains an effective implant material for nasal augmentation in rhinoplasty. The complication rate in primary cases is low. The risk of infection necessitating removal rises significantly in revision cases, where its use may still be desirable but must be weighed more carefully.
Explore the source record for details and available documents.
OBJECTIVE: To test 4 previously published outcomes instruments (the Facelift Outcomes Evaluation, the Rhinoplasty Outcomes Evaluation, the Blepharoplasty Outcomes Evaluation, and the Skin Rejuvenation Outcomes Evaluation) in terms of their reliability and validity in assessing patient-related outcomes of surgical intervention. DESIGN: A prospective pilot study of 78 patients in 3 similar private cosmetic surgery centers undergoing a total of 100 face-lift, rhinoplasty, blepharoplasty, and skin rejuvenation procedures. Patients were evaluated at 2 preoperative and 1 postoperative time points and the instruments were analyzed with regard to their test-retest reliability, internal consistency, and responsiveness to change. RESULTS: All 4 outcomes instruments had excellent reliability, consistency, and validity scores. Test-retest reliability was 0.74 to 0.83 (Pearson correlation coefficients), internal consistency scores were.83 to.88 (Cronbach alpha), and responsiveness to change was statistically significant for each instrument tested (P< or =.001). In addition, patients experienced significant quality of life improvement, with overall satisfaction increasing on average from 37% to more than 84% after these procedures. CONCLUSIONS: These 4 instruments are reliable and valid and can be used to accurately assess patient-related satisfaction in studies of face-lift, rhinoplasty, blepharoplasty, and skin resurfacing outcomes. These brief questionnaires provide the cosmetic surgeon with quantitative tools to evaluate otherwise subjective and purely qualitative outcomes and are recommended for use in future prospective studies.
Inferior pancreaticoduodenal artery aneurysms are uncommon visceral artery aneurysms usually difficult to resect, and, if untreated, have a propensity to rupture with catastrophic results. We reviewed the clinical and treatment records of four patients encountered in our institution within the last 4 years. Three patients presented as bleeding emergencies from single aneurysms and were successfully treated by transcatheter embolization using coaxial technique and a variety of embolic agents. One nonemergent, asymptomatic patient had surgical resection of two inferior pancreaticoduodenal artery aneurysms due to unfavorable anatomy for embolization. Embolization therapy appears to be the treatment of choice in the emergency setting. Patients with unsuitable anatomy for embolization may still require surgical intervention.
Explore the source record for details and available documents.
The finished sequence of human chromosome 20 comprises 59,187,298 base pairs (bp) and represents 99.4% of the euchromatic DNA. A single contig of 26 megabases (Mb) spans the entire short arm, and five contigs separated by gaps totalling 320 kb span the long arm of this metacentric chromosome. An additional 234,339 bp of sequence has been determined within the pericentromeric region of the long arm. We annotated 727 genes and 168 pseudogenes in the sequence. About 64% of these genes have a 5' and a 3' untranslated region and a complete open reading frame. Comparative analysis of the sequence of chromosome 20 to whole-genome shotgun-sequence data of two other vertebrates, the mouse Mus musculus and the puffer fish Tetraodon nigroviridis, provides an independent measure of the efficiency of gene annotation, and indicates that this analysis may account for more than 95% of all coding exons and almost all genes.
We describe a case of lipoblastoma causing respiratory symptoms in an infant, where CT was useful in establishing the diagnosis and demonstrating the extent of involvement so that complete surgical resection could be planned.
Six ponies divided into two groups of three were used in a double crossover study design. Group 1 ponies had a small intestinal resection and anastomosis performed using a biofragmentable anastomosis ring (BAR); group 2 ponies had a hand-sewn small intestinal resection and anastomosis using a Gambee suture pattern. Approximately 30 days later, all ponies had a second celiotomy and anastomosed segments were removed. Group 1 ponies had a hand-sewn anastomosis performed and group 2 had a BAR. The anastomotic sites were collected at necropsy approximately 30 days later. Anastomosed intestinal segments were evaluated with ultrasound to determine lumen diameter, area, circumference, and wall thickness. Gross descriptions of adhesions were recorded and sections of the anastomotic site were taken for histological evaluation. Time to perform the BAR anastomosis was significantly less (P = .0004) than for the hand-sewn Gambee anastomosis. Ponies with handsewn anastomoses had no signs of colic, whereas five of six ponies with BAR anastomoses had several episodes of abdominal discomfort, between day 16 to 18, corresponding to the time of BAR disintegration as determined by abdominal radiographs. Hand-sewn anastomoses had a tendency to have more adhesion formation than BAR anastomoses, but all anastomoses, except one BAR anastomosis, were graded as having a low obstructive potential. BAR anastomoses had a significantly larger mean index of stenosis for intraluminal diameter (76% +/- 13.6), area (93.7% +/- 6.01) and circumference (75.8% +/- 14.0) than the hand-sewn anastomoses (26.6% +/- 11.9; 44.6% +/- 19.5; 26.8% +/- 12.7). The BAR anastomoses also had a significantly smaller mean intraluminal diameter (0.96 cm +/- 0.49), area (0.838 cm2 +/- 0.65) and circumference (3.28 cm +/- 1.63) than the hand sewn anastomoses (3.11 cm +/- 0.73; 7.99 cm2 +/- 3.9; 10.3 cm +/- 2.47). In addition, the BAR anastomoses had a significantly larger (P = .0069) bowel wall thickness at the anastomoses and a significantly larger (P = .047) wall thickness proximal to the anastomosis than the hand-sewn anastomoses, indicating some degree of hypertrophy because of chronic obstruction. No significant difference was found in the diameter, area, or circumference between bowel proximal and distal to the anastomosis for either the BAR or Gambee techniques, or between the BAR and Gambee anastomosis as a measure of chronic obstruction. There was a significantly higher (P = .0043) histological score (worse healing) for mucosal healing and continuity for the BAR, as well as a tendency to score higher for inflammation, anastomotic alignment, and anastomotic fibrosis. The BAR technique had a significantly higher (P = .0043) total histological score than the Gambee technique. Although the BAR was advantageous in many respects, results of this study suggest that it should not be used for equine small intestinal anastomosis because of the potential for stricture formation.
This work presents a novel investigation of an NMR device to measure blood flow. Continuous-wave magnetic resonance scanners are now available for noninvasive peripheral blood flow measurements. The appearance of dedicated peripheral blood flow scanners in the clinical setting requires analysis of system performance. No reports were found that explore methods or results of clinical MR blood flow scanner performance evaluation. This work was undertaken to identify the testing procedures and characteristics of a clinical, dedicated NMR blood flow scanner. The dependence of flow measurement on tubing size, material, offset from isocenter, and angulation was examined. In addition, the precision and accuracy of the scanner were investigated. The results demonstrate a strong dependence between the measured blood flow and both the tube size and flow rate. The tube offset results exhibited a region of weak dependence in the center of the bore, which becomes stronger near the edge. The measured flow rate was found to be relatively insensitive to tube angles less than 30 degrees to 55 degrees. The repeatability was typically better than 5% and the table positioning was found to be highly accurate.
The purpose of this study was to review the positive angiographic findings in patients with polyarteritis nodosa (PAN). The authors reviewed the angiograms of 56 consecutive patients (25 women and 31 men; age range, 18-81 years; mean age, 55 years) with PAN and arterial abnormalities consistent with necrotizing vasculitis. Aneurysms were present in 27 patients and segments of ectasia were present in seven patients, for a total of 34 (61%) of 56 patients with aneurysmal lesions. The remaining 22 (39%) patients had arterial lesions that were occlusive: luminal irregularity, stenosis, or occlusion. All but one of the patients with an aneurysm also had occlusive lesions. Therefore, 55 (98%) of the 56 patients were found to have occlusive lesions. Skeletal muscle arteries were affected in 18 patients, nine in the extremities. The most frequent finding in patients with PAN was occlusive arterial lesions. Although the presence of aneurysms increases specificity for the diagnosis of PAN, many patients have only occlusive lesions. Involvement of skeletal muscle arteries was common.
Experiments were designed to determine the viability of endothelial cells and their responses to products released by aggregating platelets following single flush perfusion of the coronary arteries with cardioplegic solutions used for cardiac transplantation. Porcine coronary arteries were perfused with crystalloid (Plegisol) or blood cardioplegic solutions; nonperfused hearts placed in 0.9% saline were used as controls. Immediately following perfusion and after 5-hour storage of the hearts in the same cardioplegic solution, rings were cut from the right coronary arteries and suspended in organ chambers for the measurement of isometric force. In some rings the endothelium was removed deliberately. The left circumflex coronary arteries were flushed with collagenase and the harvested endothelial cells were plated for cell culture. Left anterior descending coronary arteries were perfusion fixed with glutaraldehyde for scanning electron microscopy. In the organ chamber experiments, aggregating platelets and adenosine diphosphate caused relaxations in rings with endothelium. These relaxations were reduced immediately following crystalloid cardioplegia and were restored following 5-hour storage. Serotonin caused contractions in all rings. Rings without endothelium were more sensitive than rings with endothelium to the amine; this difference was augmented following 5-hour storage of the heart. Significantly fewer foci of endothelial cells grew in culture following 5-hour storage of the hearts in crystalloid cardioplegic solution compared to control (p < 0.05). There were no anatomical differences identified among groups by scanning electron microscopy. These results suggest that crystalloid cardioplegia alters the responses of coronary arteries to substances released by aggregating platelets and reduces the ability of endothelial cells to replicate. Such changes may contribute to altered vascular resistance following reperfusion of transplanted hearts and potentially to later structural changes in the coronary arteries.