PubMed Health⌕ Search

Biomedical subjects

C M Preissner

Publications and source records attributed to C M Preissner.

8 recordsLinked to original sources

Quantitation of 14-3-3 and neuron-specific enolase proteins in CSF in Creutzfeldt-Jakob disease.

CSF 14-3-3 and neuron-specific enolase (NSE) proteins were quantitated from patients who had Creutzfeldt-Jakob disease (CJD) or other rapidly dementing disorders initially considered to be CJD. Thirty-one patients were diagnosed as having CJD among 152 studied. CSF 14-3-3 values more than 8 ng/mL correlated with CJD. CSF NSE values less than 30 ng/mL and 14-3-3 values less than 8 ng/mL made a diagnosis of CJD unlikely, but did not exclude it.

14-3-3 Proteins↗

Development of a highly sensitive immunochemiluminometric assay for prostate-specific antigen.

OBJECTIVES: An assay is described for measuring very low concentrations of prostate-specific antigen (PSA) which could be used to reliably monitor patients with radical prostatectomies potentially to detect early recurrence of prostate cancer. METHODS: A combination of immobilized and acridinium ester-labeled monoclonal antibodies was used to develop a two-step, 90-minute chemiluminometric assay. The reference standards for the serum assays were prepared by adding patient sera with a high concentration of PSA to base pools of female sera, which were selected because of low background counts and good recovery of added PSA. The assay was standardized to match the Abbott IMx PSA Assay. RESULTS: The serum-based analytic detection limit (calculated as response 2.5 standard deviations [SD] above the zero standard) is 0.004 ng/mL, whereas the "biologic detection limit" (calculated as 2.0 SD above the analytic detection limit) is 0.008 ng/mL. The assay is highly reproducible with interassay coefficients of variation (CV) under 12% down to 0.02 ng/mL, qualifying this as a "second generation" assay (eg, CV < 20% at 0.05 ng/mL). CONCLUSION: This assay can measure very low concentrations of PSA in plasma and a wide range of PSA concentrations in urine. This assay will provide a valuable analytic tool for the future evaluation of the clinical utility of "ultrasensitive" PSA measurements for the management of prostate cancer.

Analysis of Variance↗

Multisite immunochemiluminometric assay for simultaneously measuring whole-molecule and amino-terminal fragments of human parathyrin.

The immunochemiluminometric assay described uses immobilized anti-human parathyrin (parathyroid hormone, hPTH)(1-44) and anti-hPTH(44-68) antisera and acridinium ester-labeled anti-hPTH(1-34) to simultaneously measure both intact hPTH and its amino-terminal fragments. Results by the assay correlate well with those by a cAMP-based bioassay and the Nichols Allegro immunoradiometric assay. The minimal detection limit is 0.08 pmol/L. The normal range is 1.0-5.0 pmol/L, and values are higher in older women. About 90% of study patients with surgically proven parathyroid adenomas had above-normal preoperative PTH concentrations, whereas patients with hypercalcemia of malignancy had normal or suppressed values. This assay was designed to detect both intact PTH and amino-terminal PTH fragments; however, chromatographic fractionation of pools of primary and secondary hyperparathyroid plasma showed virtually no amino-terminal fragment activity. Nonetheless, the design is important because the absence of carboxyl-terminal binding sites prevents interference by carboxyl-terminal fragments and because bioactive amino-terminal fragments will react in the assay if they are present in the patients' sera or if they are produced by in vitro proteolysis of intact PTH.

Chromatography↗

Free alpha subunit of the pituitary glycoprotein hormones. Measurement in serum and tissue of patients with pituitary tumors.

A solid-phase radioimmunoassay was developed that measures the free alpha subunits of pituitary glycoprotein hormones (alpha PGpHs) and has negligible cross-reactivity with the intact hormones (less than 0.014% for thyroid-stimulating hormone [TSH], less than 0.1% for human chorionic gonadotropin [hCG], 0.8% for luteinizing hormone [LH], and 2.0% for follicle-stimulating hormone [FSH]). The assay is standardized with the alpha subunit of hCG but also reacts well with the alpha subunits of the other glycoprotein hormones (84% for alpha TSH, 77% for alpha FSH, and 64% for alpha LH). Concentrations as low as 0.3 micrograms/L can be reliably measured, and the 97.5% reference range in 27 healthy adults, including postmenopausal females, is less than or equal to 1.2 micrograms/L. Elevated preoperative alpha PGpH concentrations were found in 45 (9.4%) of 479 sera from patients with pituitary adenoma and 3 (4.5%) of 66 patients with nonadenomatous sellar lesions. Postoperative alpha PGpH levels were lower in 30 of 39 adenoma patients and 2 of 3 nonadenoma patients. In five (1%) of the patients with pituitary adenomas, alpha PGpH was the only elevated serum hormone marker. Serum values of alpha PGpH correlate weakly with alpha subunit immunocytochemical staining--95% of those with negative staining have normal alpha PGpH values, but only 18% of those with positive staining have elevated alpha PGpH values.

Adenoma↗

Bioassay of parathyrin: analytical characteristics and clinical performance in patients with hypercalcemia.

This new bioassay for parathyrin (PTH) in plasma (bio-PTH) combines immunoextraction on affinity columns [goat anti-hPTH (1-44) conjugated to Sepharose 4B] and a receptor assay involving an osteosarcoma cell line. The mean extraction efficacy ranges from 87% (as determined with immunopurified 125I-labeled PTH) to 62% for hPTH bioactivity. The assay is standardized with synthetic hPTH (1-84) and can detect as little as 0.9 pmol/L of PTH in 2 mL of plasma. In 100 healthy adults, the 95% reference interval for bio-PTH was less than 0.9 to 6.1 pmol/L (median, 2.0 pmol/L). In 185 patients with surgically confirmed hyperparathyroidism, bio-PTH concentrations ranged from 1.0 to greater than 120 pmol/L (median, 12.9 pmol/L); 80% of values were greater than 6.1 pmol/L. In 50 patients with both preoperative and postoperative determinations, the mean (+/--SD) concentrations of calcium in serum were 113 +/- 10 and 89 +/- 6 mg/L, respectively; the median bio-PTH concentrations were 13.6 and 2.0 pmol/L, respectively. In 22 patients with nonparathyroid-mediated hypercalcemia, the concentration of bio-PTH ranged from less than 0.9 to 5.3 pmol/L (median, 1.8 pmol/L). This bio-PTH assay is slightly less sensitive than our GP235 immunoreactive PTH (iPTH) immunoassay for detecting hyperparathyroidism (Clin Chem 1982;28:69-74); however, the bioassay is more specific and detected some cases missed by the iPTH assay. Overall, 95% of the hyperparathyroid patients had an increased test result for either the bio-PTH or the iPTH assay.

Adult↗

Nonisotopic "sandwich" immunoassay of thyroglobulin in serum by the biotin-streptavidin technique: evaluation and comparison with an immunoradiometric assay.

In this sequential assay, the thyroglobulin in serum binds to polystyrene beads coated with two mouse monoclonal antibodies. These beads then react with a rabbit polyclonal antibody, biotinylated sheep anti-rabbit IgG, streptavidin-horseradish peroxidase, and a peroxidase substrate to yield a colored product that is measured spectrophotometrically at 492 nm. The range of the standard curve is 1.6 to 100 micrograms/L. The detection limit of the assay is 1.2 micrograms/L. The interassay coefficient of variation is 14.0% at 6.2 micrograms/L, 5.7% at 32.7 micrograms/L; the intra-assay CVs range from 7.8% to 14.8%. The reference intervals are 2.7 to 42.1 micrograms/L for euthyroid persons and less than or equal to 5 micrograms/L for athyreotic patients not on thyroxin replacement therapy. Some autoantibodies to thyroglobulin cause thyroglobulin values to be falsely low. The concentration of autoantibodies is not correlated with the analytical recovery of human thyroglobulin. The coefficient of correlation between the measurement of thyroglobulin by this assay and by an immunoradiometric assay was 0.969 for 186 autoantibody-negative samples, 0.963 for 37 autoantibody-positive samples.

Adult↗

Heterophilic serum antibodies: a cause for falsely elevated serum thyrotropin levels.

We report two cases of euthyroid patients with inappropriately elevated serum levels of thyrotropin (TSH) in whom investigation led to the detection of heterophilic antibodies. In addition, we compare the performance of two TSH immunometric assay systems in this setting. Even when monoclonal assay systems are used, TSH results must be critically interpreted when they are at variance with clinical and other biochemical findings.

Adult↗

Evaluation of the anticomplement immunofluorescence test for detection of antibody to varicella-zoster virus.

The anticomplement immunofluorescence (ACIF) test was compared with complement fixation and fluorescent antibody to membrane antigen procedures for the detection of antibody to varicella-zoster virus. All of 50 sera from pregnant women contained antibody measured by ACIF (titer, greater than or equal to 1:10); only 27 (54%) were positive by complement fixation (P less than 0.01). For 16 paired sera obtained before and after varicella-zoster virus infection and tested by ACIF and fluorescent antibody to membrane antigen, the result agreed in 27 determinations (sensitivity, 94%; specificity, 81%). Of 99 sera submitted for routine determinations of immune status to the virus, 89 showed comparable results for both tests (sensitivity, 92.5%; specificity, 88%). The ACIF test offers a specific and sensitive alternative to the fluorescent antibody to membrane antigen procedure for the detection of antibody to varicella-zoster virus. In addition, the ACIF test is rapid, easy to perform, and uses commercially available reagents.

Antibodies, Viral↗