PubMed Health⌕ Search

Biomedical subjects

C M Savage

Publications and source records attributed to C M Savage.

5 recordsLinked to original sources

Energetically stable particlelike skyrmions in a trapped Bose-Einstein condensate.

We numerically show that a topologically nontrivial 3D Skyrmion can be energetically stable in a trapped two-component atomic Bose-Einstein condensate, for the parameters of 87Rb condensate experiments. The separate conservation of the two atomic species can stabilize the Skyrmion against shrinking to zero size, while drift of the Skyrmion due to the trap-induced density gradient can be prevented by rotation or by a laser potential.

Journal Article↗

Stability of continuously pumped atom lasers.

A multimode model of a continuously pumped atom laser is shown to be unstable below a critical value of the scattering length. Above the critical scattering length, the atom laser reaches a steady state, the stability of which increases with pumping. Below this limit the laser does not reach a steady state. This instability results from the competition between gain and loss for the excited states of the lasing mode. It will determine a fundamental limit for the linewidth of an atom laser beam.

Journal Article↗

Low-dose versus high-dose heparinization during arteriovenous carbon dioxide removal.

The purpose of this study was to compare low-dose (LD) and high-dose (HD) systemic heparinization in a prospective randomized study of arteriovenous carbon dioxide removal (AVCO2R) during acute respiratory distress syndrome, using a commercially available heparin-coated oxygenator. Adult sheep (n = 13) received an LD50 smoke inhalation and 40% TBSA third degree cutaneous flame burn injury. At 40-48 h post-injury, animals underwent cannulation of the carotid artery and jugular vein and were then randomized to HD heparin (activated clotting time, ACT > 300s, n = 6) and LD heparin (ACT < 200s, n =7) and placed on AVCO2R for approximately 72 h using an oxygenator with the Trillium Bio-Passive Surface. Mean ACTs were significantly different, as expected (HD: 446 +/- 26s, LD: 213 +/- 12s, p < 0.05). AVCO2R shunt flow averaged approximately 13% of cardiac output with mean CO2 removal similar in HD and LD, p = NS. The hematocrit, platelet count, and fibrin degradation products for the two groups were not different. No differences in thrombosis or bleeding were noted. In conclusion, LD systemic heparin (ACT < 200s) with a heparin-coated oxygenator does not increase thrombogenicity during AVCO2R for smoke/burn-induced severe lung injury in sheep.

Acute Disease↗