PubMed Health⌕ Search

Biomedical subjects

C M Steyers

Publications and source records attributed to C M Steyers.

22 records · Page 2Linked to original sources

A microvascular anastomotic device: Part II. A histologic study in arteries and veins.

This study analyzes the histology associated with the polyethylene ring-pin device. The device was placed in 20 rabbit femoral arteries and 20 femoral veins. Specimens were harvested at 24-hour and 3-week postoperative intervals and were analyzed using light, scanning electron, and transmission electron microscopy. Generally, the reparative process in the arteries and veins was similar. In 24-hour artery and vein specimens, the endothelial cells were absent, the media tapered within the device, but smooth muscle cells (SMC) remained partially viable. In 3-week specimens, the device junction was well healed and reendothelialized. Subintimal hyperplasia was present, the internal elastic lamina was not reconstituted, and the SMCs were partially viable. Small vascular channels formed at the device junction, and small venous valves were noted near the device. Macrophages lined the margins of the device. The early reparative process proceeds favorably, by histologic criteria, after vessel repair with the polyethylene ring-pin device.

Anastomosis, Surgical↗

Measuring ulnar variance: a comparison of techniques.

This study compared three commonly used methods of measuring ulnar variance. The comparison included the project- a-line technique (A), the method of concentric circles (B), and the method of perpendiculars (C). Specific features studied were variations in results generated by each technique as well as the interobserver and intraobserver reliability for each technique. The only significant difference among techniques was between techniques A and B (p = 0.0224), where mean A values were more positive than mean B values. Observers were found to differ significantly (p = 0.0092) independent of technique. All methods studied were highly reliable, although the method of perpendiculars was most reliable for both interobserver (reliability = 0.9801) and intraobserver (reliability = 0.9719) reliability. This study shows that the clinician may choose whichever technique he prefers when measuring ulnar variance.

Anthropometry↗

Large lipomas in the deep palmar space.

Lipoma in the deep palmar space of the hand is an unusual tumor. Our experience with seven of these tumors indicates that they can be unusually large at initial examination, can first be seen with paresthesias in branches of the median nerve, and can be difficult to surgically expose. Marginal resection of this tumor is curative.

Aged↗

Crossed intrinsic transfer.

A retrospective analysis of the long-term results of the crossed intrinsic transfer operation is presented. Twenty-one patients (30 hands) with rheumatoid arthritis and one patient (1 hand) with systemic lupus erythematosus were examined clinically and radiographically. The average follow-up was 12.7 years. The average postoperative ulnar drift for all fingers was 5 degrees. The magnitude of ulnar drift did not increase over time. The average active range of motion for the metacarpophalangeal joints was 47 degrees and for the proximal interphalangeal joints it was 58 degrees. The average radial deviation deformity of the wrist in the resting position was 2 degrees. These variables did deteriorate with time. Extensor carpi radialis longus to extensor carpi ulnaris tendon transfer with crossed intrinsic transfer produced the same result as crossed intrinsic transfer alone. The outcomes for crossed intrinsic transfer attached to the lateral band were similar to outcomes for transfers attached to the collateral ligament of the metacarpophalangeal joint. The crossed intrinsic transfer procedure effectively provides long-term correction of ulnar drift in the rheumatoid hand.

Adult↗