PubMed Health⌕ Search

Biomedical subjects

C Madison

Publications and source records attributed to C Madison.

3 recordsLinked to original sources

Use of interreflection and shadow for surface contact.

The interaction of light with surfaces results in a number of lighting effects that may serve as valuable visual cues. Previous research on shadows has shown them to be effective in determining the three-dimensional (3-D) layout of a scene, but interreflections have been ignored as cues for spatial layout. Interreflections as well as shadows may help to disambiguate the 3-D layout of objects by providing information about an object's contact with a surface. We generated computer images of a box on an extended textured ground plane that was either in contact with the ground or was slightly above the ground. Images were rendered for four conditions: (1) no shadow + no interreflection, (2) shadow only, (3) interreflection only, and (4) shadow + interreflection. A photometrically incorrect condition was also included. The participants rated the degree of contact for each image on a scale, which was used to generate receiver operating characteristic (ROC) curves and a measure of sensitivity. In the images with no shadows or interreflections, the participants performed at chance levels. Interreflections, shadows, and a combination of interreflections and shadows all resulted in high sensitivity for judging object contact. More important, information from shadows and interreflections can be combined, resulting in near-perfect judgment of surface contact. Interreflections and shadows can be effective cues for object contact.

Attention↗

Thermodilution cardiac output values obtained by using a centrally placed introducer sheath and right atrial port of a pulmonary artery catheter.

Thermodilution cardiac output measurements obtained using a centrally placed introducer sheath were compared with thermodilution cardiac outputs obtained using the right atrial port of a balloon-tip, flow-directed pulmonary artery catheter in 15 patients with cardiac failure. Cardiac output values were obtained by manually injecting 10 ml of iced, D5W alternately through the introducer sheath and the right atrial port of the flow-directed catheter. Thirty cardiac output readings were obtained in the 15 patients. Cardiac outputs obtained using the right atrial port (CORA) did not differ significantly from cardiac outputs obtained using the introducer sheath (COSP) (5.3 +/- 0.2 vs. 5.2 +/- 0.2 L/min). The correlation between CORA and COSP was significant (r = .94, p less than .0001) and could be described by the formula CORA = 0.33 + 0.96 COSP. We conclude that when the right atrial port of a flow-directed catheter is nonfunctional, a thermodilution cardiac output obtained using a centrally placed introducer sheath offers a reliable alternative.

Adult↗