PubMed Health⌕ Search

Biomedical subjects

C McClure

Publications and source records attributed to C McClure.

9 recordsLinked to original sources

Risk prediction in patients presenting with suspected cardiac pain: the GRACE and TIMI risk scores versus clinical evaluation.

BACKGROUND: Identifying which patients presenting with undifferentiated chest pain are at risk of major cardiac events is a major clinical challenge. Clinical evaluation may lack sufficient precision, leading to unnecessary admission or inappropriate discharge. It is uncertain whether risk scores derived from ACS populations apply to unselected patients with chest pain. AIM: To determine the predictive accuracies of the GRACE risk score, the TIMI risk score and clinical evaluation in unselected patients with suspected cardiac pain. DESIGN: Prospective observational study. METHODS: We recruited 347 sequential patients with suspected cardiac pain presenting to a large teaching hospital. The main outcome measures were death, non-fatal myocardial infarction and emergency revascularization, in hospital and at 3 months. Receiver operating characteristic (ROC) curves were plotted for TIMI and GRACE risk scores and clinical evaluation. RESULTS: Overall 54 patients (15.6%) experienced a major cardiac event (16 deaths, seven myocardial infarctions (MIs), one emergency revascularization) or emergency re-admission (n=30) within 3 months. Both GRACE (p<0.001) and TIMI scores (p<0.001) predicted death/MI/revascularization (and the composite including re-admission), but the GRACE score was superior to the TIMI score for predicting major cardiac events (z=2.05), and both scores were superior to clinical evaluation (ROC areas 0.82, 0.74 and 0.55 respectively). The GRACE score predicted an ACS discharge diagnosis (p<0.001) and duration of hospital stay (p<0.001). DISCUSSION: In unselected patients presenting with suspected cardiac pain, the GRACE risk score is superior to the TIMI risk score in predicting major cardiac events, and both risk scores are superior to using ECG and troponin findings at presentation.

Aged↗

Structure-activity relationship studies of flavopiridol analogues.

Cyclin dependent kinases (CDKs) along with the complementary cyclins form key regulatory checkpoint controls on the cell cycle. Flavopiridol is a synthetic flavone that shows potent and selective cyclin-dependent kinase inhibitory activity. In this paper, we report modifications of the 3-hydroxy-1-methylpiperidinyl (D ring) of flavopiridol and their effect on CDK inhibitory activity.

Antineoplastic Agents↗

Development of a ubiquitin transfer assay for high throughput screening by fluorescence resonance energy transfer.

An assay based on fluorescence resonance energy transfer (FRET) has been developed to screen for ubiquitination inhibitors. The assay measures the transfer of ubiquitin from Ubc4 to HECT protein Rsc 1083. Secondary reagents (streptavidin and antibody to glutathione-S-transferase [GST]), pre-labeled with fluorophores (europium chelate, Eu(3+), and allophycocyanin [APC]), are noncovalently attached via tags (biotin and GST) to the reactants (ubiquitin and Rsc). When Rsc is ubiquitinated, Eu(3+) and APC are brought into close proximity, permitting energy transfer between the two fluorescent labels. FRET was measured as time-resolved fluorescence at the emission wavelength of APC, almost entirely free of nonspecific fluorescence from Eu(3+) and APC. The FRET assay generated a lower ratio of signal to background (8 vs. 31) than an assay for the same ubiquitination step that was developed as a dissociation-enhanced lanthanide fluoroimmunoassay (DELFIA). However, compared to the DELFIA method, use of FRET resulted in higher precision (4% vs. 11% intraplate coefficient of variation). Quenching of fluorescence was minimal when compounds were screened at 10 microg/ml using FRET. Employing a quick and simple homogeneous method, the FRET assay for ubiquitin transfer is ideally suited for high throughput screening.

Dimethyl Sulfoxide↗

Correlation of 9G4 idiotope with disease activity in patients with systemic lupus erythematosus.

OBJECTIVE: To compare the levels of the 9G4 idiotope (9G4 Id) in systemic lupus erythematosus (SLE) patients with a detailed disease activity index, the British Isles Lupus Assessment Group (BILAG) index, and serological parameters of disease activity by ds DNA antibody levels and serum C3 concentrations. METHODS: In a cross sectional analysis serum samples from 190 patients with SLE were studied and a further 55 serial bleeds from 14 patients. An enzyme linked immunosorbent assay was used to measure the 9G4 Id, and anti dsDNA and antimyeloperoxidase (MPO) antibodies. The C3 levels were measured by laser nephelometer. RESULTS: Seventy six of 190 (40%) of the patients tested had raised 9G4 Id levels. In the cross sectional study 9G4 Id levels were found to correlate with disease activity in the BILAG cardiovascular/respiratory renal, and haematological systems and with global BILAG score (p < 0.01). In the serial bleeds 9G4 Id levels correlated with anti-dsDNA antibody and C3 levels, but not with anti-MPO antibodies. No correlations were found with treatment. In six cases the 9G4 Id levels correlated well with global BILAG scores and dsDNA antibody levels. In four cases the BILAG global and 9G4 Id levels alone correlated well. CONCLUSIONS: Raised levels of the 9G4 Id are present in a substantial proportion of serum samples from patients with lupus, correlate with various aspects of disease activity in SLE. The Id is detectable on anti-dsDNA antibodies, though it must also be present on other immunoglobulins whose specificities remain unknown.

Antibodies, Antinuclear↗

Experience with use of multiplane transesophageal echocardiography to guide closure of atrial septal defects using the amplatzer device.

By providing unlimited imaging planes, multiplane transesophageal echocardiography (MTEE) should improve real-time guidance of interventional procedures. The potential advantages of MTEE in this scenario have not been systematically evaluated. We retrospectively reviewed our experience with MTEE-guided Amplatzer device closure of atrial septal defects (ASDs) MTEE angles used to obtain images for guiding all measurements and maneuvers were recorded. These angles were compared to the range of MTEE angles that are postulated to be available from biplane TEE. Images obtained using MTEE angles from 21 degrees to 70 degrees and from 111 degrees to l59 degrees were defined as only obtainable by MTEE. The MTEE probe was successfully introduced in all (89) patients. Thirteen patients (15%) had multiple defects. Ninety-five devices (5-32 mm in diameter) were deployed. In 66% of patients, balloon sizing and device deployment necessitated imaging planes that are only obtainable by MTEE. All devices were well positioned, with no impingement on inflows or outflows. At follow-up, 79 of 89 (88.7%) patients had no residual ASDs. Each of the remaining 10 patients (11.3%) had a small (<3 mm) residual defect. MTEE played an important role in guiding device closure of ASD, particularly during the phases of balloon sizing and device deployment.

Adolescent↗

Buying software off the rack. Packages can be the solution to the software shortage.

The rapid pace of the computer revolution may well be slowed by the lack of suitable software. Though computers should be increasing business efficiency and productivity, many companies do not have the software that would enable them to enjoy these benefits. Packaged software can close the gap for both large and small companies. Here are some guidelines for making the decision whether to buy a package and for avoiding trouble once the package is installed. The article also describes the features a company should look for in packaged software and the optimal provisions of a software contract.

Computers↗