Mammographic film-processor temperature, development time, and chemistry: effect on dose, contrast, and noise.

Six different combinations of film-processor temperature (33.3 degrees C, 35 degrees C), development time (22 sec, 44 sec), and chemistry (Du Pont medium contrast developer [MCD] and Kodak rapid process [RP] developer) were each evaluated by separate analyses with Hurter and Driffield curves, test images of plastic step wedges, noise variance analysis, and phantom images; each combination also was evaluated clinically. Du Pont MCD chemistry produced greater contrast than did Kodak RP chemistry. A change in temperature from 33.3 degrees C (92 degrees F) to 35 degrees C (95 degrees F) had the least effect on dose and image contrast. Temperatures of 36.7 degrees C (98 degrees F) and 38.3 degrees C (101 degrees F) also were tested with extended processing. The speed increased for 36.7 degrees C but decreased at 38.3 degrees C. Base plus fog increased, but contrast decreased for these higher temperatures. Increasing development time had the greatest effect on decreasing the dose required for equivalent film darkening when imaging BR12 breast equivalent test objects; ion chamber measurements showed a 32% reduction in dose when the development time was increased from 22 to 44 sec. Although noise variance doubled in images processed with the extended development time, diagnostic capability was not compromised. Extending the processing time for mammographic films was an effective method of dose reduction, whereas varying the processing temperature and chemicals had less effect on contrast and dose.

Female↗

Simultaneous electronic and small format photofluorographic angiography.

Monitoring the image on the television screen during photofluorographic angiography is frequently difficult due to the short exposure times. A disk recorder has been integrated with a 100mm rapid-sequence photofluorographic camera for use during selected angiographic procedures. Each flashing image is automatically recorded on the disk recorder and is then immediately replayed during the interval between exposures. It is these considerably longer, although minimally delayed images, that are viewed during the study instead of the short live image. "Panning" to follow the progression of the contrast bolus is facilitated. The recorded angiographic series may be instantly replayed in stop motion for immediate review.

Angiography↗