Time to first shock in implantable cardioverter defibrillator (ICD) patients with Chagas cardiomyopathy.

UNLABELLED: The time to first ICD shock has been extensively studied in patients with coronary artery disease (CAD). However, there are no published data on ICD shocks in patients with Chagas cardiomyopathy (ChC). The occurrence of the first appropriate ICD shock during the first 6 months of follow-up in 20 patients with ChC (group 1) and 35 CAD patients (group 2) was analyzed retrospectively. All patients had received a third-generation pectoral ICD for ventricular tachycardia or fibrillation (VT/VF). Indications for ICD implantation were refractoriness to drug therapy or noninducibility of VT/VF at EPS in cardiac arrest survivors. RESULTS: The mean age, left ventricular ejection fraction (LVEF), and sex in groups I and II were 57.4 +/- 7 years versus 64 +/- 9 (P < 0.01), 30.9% +/- 10% versus 32.9% +/- 10% (P = NS), and 10 men versus 31 women (P < 0.005), respectively. Six months after ICD implantation, 85% (17/20) group I patients received appropriate ICD shocks versus 51% (18/35) in group 2, a statistically significant difference (P < 0.02, RR: 1.65, OR: 5.35). CONCLUSIONS: The incidence of appropriate ICD shocks within the first 6 months postimplantation was significantly higher in ChC patients than in CAD patients. ChC patients were younger and more often women than CAD patients.

Adult↗

Implantable cardioverter defibrillators in patients with Chagas' disease: are they different from patients with coronary disease?

Chagas' disease is a parasitic affliction, endemic to certain regions of South America, which may lead to a chronic dilated nonischemic cardiomyopathy. Ten Chagasic patients were compared to 18 coronary patients undergoing transvenous ICD implantation for ventricular tachycardia (VT), ventricular fibrillation (VF), or aborted cardiac arrest. Indications for ICD implantation were either drug intolerance or refractoriness, or no inducible tachyarrhythmia at EPS. There were no statistically significant differences between the Chagas and coronary artery disease groups with respect to age (60.2 vs 62.6 yrs), NYHA Class II (50% vs 62%), ejection fraction (31.1% vs 29.7%), and incidence of cardiac arrest (20% vs 33%), respectively. The following ICD implant and long-term follow-up variables were compared between the two groups: pacing threshold (0.94 V vs 0.95 V), defibrillation threshold (19.5 J vs 19.6 J), number of VT episodes (414 vs 435), number of spontaneous VT terminations (86 vs 187), percent efficacy of antitachycardia pacing (93.9% vs 92.1%), and total number of shocks (112 vs 145). These differences were not statistically significant. We conclude that patients with Chagas' disease, compared with coronary artery disease patients, have similar clinical characteristics leading to ICD implantation. Furthermore, no differences were found with respect to ICD and long-term follow-up characteristics between the two groups.

Age Factors↗

[Tilt test for the evaluation of syncope of unknown origin].

UNLABELLED: The aim of this study was to evaluate the usefulness of head up tilt testing in patients with syncope of unknown origin. Between January 1994 and September 1995, 93 patients were referred for tilt table assessment due to recurrent syncope of uncertain etiology. There were 42 men (mean age 59 years). Thirty healthy volunteers served as a control group. The specific protocol used involved an initial period of supine rest for 15'. Baseline blood pressure (BP) and heart rate (HR) were recorded. This was followed by a tilt to 80 degrees for 30', BP and HR were measured every minute during the procedure. The test was considered positive when symptoms appeared associated with one of the following responses: systolic BP decreased more than 30 mmHg (vasodepressor), bradicardia or asystolia for up to 3" (cardioinhibitory) or mixed. RESULTS: The tilt test was positive in 31 of 93 patients (33%). Seventeen patients (55%) had a vasodepressor response, 3 patients (9%) a cardioinhibitory response and 11 patients (36%) mixed responses. The clinical manifestations were 62% near syncope, 19% syncope and the other patients presented dypsnea or dizziness. The symptoms disappeared promptly after adopting the supine position. None of the 30 healthy volunteers developed symptoms. We conclude that head up tilt test is a safe and effective method for identifying a neurocardiogenic origin in a syncope of uncertain etiology.

Adolescent↗

Results of delivered therapy for VT or VF in patients with third-generation implantable cardioverter defibrillators.

Third-generation implantable cardioverter defibrillators (ICDs) offer tiered therapy and can provide significant advantage in the management of patients with life-threatening arrhythmias. Three different types of ICDs were implanted in 21 patients with ventricular tachycardia (VT) or ventricular fibrillation (VF). Arrhythmia presentation was VT (76%), VF (10%), or both (14%). The mean left ventricular ejection fraction for the group was 32.4 +/- 7%. No surgical mortality occurred. Prior to discharge individual EPS determined the final programmed settings of the ICDs. During a mean follow-up of 13 +/- 1.4 months (range 2-20) the overall patient survival was 85.7%. No sudden arrhythmic or cardiac death occurred. Twenty of 21 patients (95%) received therapy by their device. In 14 patients (67%) antitachycardia pacing (ATP) was programmed "on," 13 of which was self-adaptative autodecremental mode. There were 247 VT episodes, 231 of which were subjected to ATP with 97% success and 3% acceleration or failure. Low energy shocks reverted all other VT episodes. VF episodes were successfully reverted by a single shock (93%), two shocks (6%), or three shocks (1%). We conclude that ATP therapy of VT is successful in the large majority of episodes with rare failures, and that VF episodes are generally terminated by a single ICD shock.

Cardiac Pacing, Artificial↗

Changing trends in therapy delivery with a third generation noncommitted implantable defibrillator: results of a large single center clinical trial.

Thirty-four patients underwent implantation of a third generation ICD, the 4210 ATP, for sudden cardiac death or ventricular tachycardia. This device incorporates significant telemetry logs as well as a detailed analysis of each arrhythmia episode detected. During the period of clinical follow-up, a mean of 12.2 months, a total of 26,569 VT or VF detections were made. The vast majority of these were either due to atrial fibrillation, nonsustained VT, or "noise" detection, and only 6% led to device therapy. ATP was successful in 86.3% of episodes, with 3.5% accelerations and 2.4% failure of ATP trains. The majority of inappropriate therapy episodes were clustered in seven patients, and all were easily diagnosed with the aid of the extensive telemetry logs and sense histories. Of five late deaths, three were from congestive heart failure, one from cerebrovascular accident, and one unknown. These data reveal that this "tiered" therapy noncommitted ICD performs to expectations; the stored data is of significant value in diagnosing the cause of ICD therapy. In addition, ATP is an effective modality for termination of VT.

Aged↗

Urine collection from disposable diapers in premature infants: biochemical analysis.

Urine collection for analysis is commonly done in premature infants in sterile adhesive bags. Leakage due to poor adherence of the bag and irritation of the skin are frequent drawbacks with this technique. Urine retrieved from the fiber padding of disposable diapers has been shown to be reliable for biochemical analysis. However, the previous studies were done under laboratory conditions and the volume of urine used was much larger than a premature infant may void at one time. The purpose of this study was to determine the reliability of urine collected from disposable diapers for biochemical analysis in premature infants in the intensive care nursery.

Disposable Equipment↗

Electrophysiologic-structural correlations in chagasic aneurysms causing malignant arrhythmias.

We studied the structure and ultrastructure of three chagasic aneurysms, the excision of which abolished malignant arrhythmias. Chronic recurrent ventricular tachycardia often occurs in patients with chagasic aneurysms, and ventricular mapping indicates that these arrhythmias originate in regions adjacent to those aneurysms. In our patients, ventricular tachycardia had been refractory to medical treatment. During surgery, epicardial and endocardial mapping showed abnormal potentials. Sutures were placed in the areas of resection, their sizes approximating those of earliest activation so that these sites could be identified. The myocardium showed chronic inflammatory reaction, myocytolysis and fibrosis. The presence of "islets" was common (normal, "early" damaged or "established" necrotic myocytes surrounded by fibrous tissue). The "early" lesions were predominant at the previously identified areas of arrhythmogenic activity. The ultrastructural studies showed hypertrophy of myocytes and partial or complete loss of myofibrils, swelling of mitochondria and disruption of mitochondrial cristae, accumulation of lipofuscin granules, and intracellular oedema. A most striking alteration was the thickening of the basement membranes of myocytes and vascular endothelial and smooth muscle cells. The interlaced fronts of respectively healthy (fast conducting) and "early" damaged (slow conducting) myocytes seen in serial sectioning produced an ideal configuration for reentry circuits. The final proof that the arrhythmias originated in these endocardial regions was their abolition by resection of the aneurysm.