Flash x-ray observations of cavitation in cadaver thighs caused by high-velocity bullets.

BACKGROUND: The purpose of this study was to record flash x-ray images of cavitation in human cadaver thighs caused by the passage of high-velocity bullets. The images are an initial step for understanding the cavitation process in human tissue and for implementing a better definition of extensive tissue injury. METHODS: Bullets were fired through the mid-thighs of 13 cadaver legs. The bullets were of two calibers, 7.62-mm full metal jacket boat tail with strike velocities in the range of 794 m/s to 880 m/s (10 thighs) and 5.70 mm full metal jacket with velocities in the range of 973 m/s to 992 m/s (3 thighs). Short duration (35 ns) x-ray images were recorded at various selected times after the bullets passed near the femurs. This study was carried out at the Armed Forces Institute of Pathology under approved human subject protocols. RESULTS: The cavity sizes and shapes were observed for the two types of bullets and at a number of times during the expansion and collapse of the cavities. As the bullets passed through the thighs, narrow cavities behind the bullets were observed. At later times, large expanded cavities were observed that encompassed the entire mid-thigh region. The observed cavities are at variance with those which were reported previously in gelatin tissue simulants. CONCLUSION: Flash x-ray radiography is an effective technique for the observation of internal cavitation in cadaver thighs caused by high-velocity bullets. These observations suggest that gelatin is not a proven simulant for human cadaver tissue in the study of cavitation subsequent to high-velocity missile impact.

Cadaver↗

Dual-energy bone densitometry using a single 100 ns x-ray pulse.

A pulsed, portable hard x-ray source has been developed for medical imaging and flash x-ray absorptiometry. The source is powered by a Marx generator that drives a field emission x-ray tube which produces a 30-300 keV x-ray pulse of 100 ns duration. The x-ray fluence has dual-energy properties. The x-ray energy is relatively high early in the pulse and lower later in the pulse. The feasibility of using a single x-ray pulse for precision bone densitometry was analyzed. A computer simulation model was developed for the x-ray source, the filtration that enhances the dual-energy distribution, the absorption of the energy distribution by bone mineral and soft tissue, and the dual-energy detection system. It is feasible to determine the bone mineral density (BMD) of axial sites such as the lumbar spine and proximal femur with 2% precision over an area that is 15-20 mm in size, depending on the bone mineral and soft tissue thicknesses. An algorithm for determining the absolute BMD, to an accuracy of 2%, using a Plexiglas/TiO2 calibration phantom is discussed. At a distance of 50 cm from the source, the patient exposure is 3.7 mR. The average absorbed bone and tissue doses are 0.6 and 4.3 mrem, respectively. Factors that facilitate diagnostic measurements in clinical settings are the short patient observation time and the portability of the x-ray source.

Absorptiometry, Photon↗