PubMed Health⌕ Search

Biomedical subjects

C N Gundry

Publications and source records attributed to C N Gundry.

2 recordsLinked to original sources

Real-time multiplex PCR assays.

The ability to multiplex PCR by probe color and melting temperature (T(m)) greatly expands the power of real-time analysis. Simple hybridization probes with only a single fluorescent dye can be used for quantification and allele typing. Different probes are labeled with dyes that have unique emission spectra. Spectral data are collected with discrete optics or dispersed onto an array for detection. Spectral overlap between dyes is corrected by using pure dye spectra to deconvolute the experimental data by matrix algebra. Since fluorescence is temperature dependent and depends on the dye, spectral overlap and color compensation constants are also temperature dependent. Single-labeled probes are easier to synthesize and purify than more complex probes with two or more dyes. In addition, the fluorescence of single-labeled probes is reversible and depends only on hybridization of the probe to the target, allowing study of the melting characteristics of the probe. Although melting curves can be obtained during PCR, data are usually acquired at near-equilibrium rates of 0.05-0.2 degrees C/s after PCR is complete. Using rapid-cycle PCR, amplification requires about 20 min followed by a 10-min melting curve, greatly reducing result turnaround time. In addition to dye color, melting temperature can be used for a second dimension of multiplexing. Multiplexing by color and T(m) creates a "virtual" two-dimensional multiplexing array without the need for an immobilized matrix of probes. Instead of physical separation along the X and Y axes, amplification products are identified by different fluorescence spectra and melting characteristics.

Animals↗

Rapid F508del and F508C assay using fluorescent hybridization probes.

Amplification and fluorescent genotyping of the cystic fibrosis F508del locus was achieved from human genomic DNA in less than 30 min. The hybridization of adjacent fluorescent probes at the mutation site was monitored by resonance energy transfer between fluorescein and Cy5 during heating or cooling. Characteristic curves were obtained for each genotype; the first derivative of these fluorescent curves has a maximum at an apparent hybridization temperature (Tm) that is specific for each probe/allele duplex. The direction and rate of temperature change determines the difference between the apparent Tm and the true equilibrium Tm. One hundred and five sample were genotyped for the F508del cystic fibrosis mutation by heating and cooling curve profiles. These genotypes were validated by allele-specific amplification. Two fluorescein hybridization probes were designed to match the wild-type sequence perfectly from either codons 502 to 513 or from 504 to 511 on the cystic fibrosis transconductance regulator gene of chromosome 7. While genotyping for the F508del, an allele with the F508C base change was detected. For both F508del and F508C variants, the Tm shift from wild type was greater with a 24-mer probe than with a 35-mer probe. Fluorescent monitoring of hybridization probes is a versatile technique that can detect unexpected sequence alterations.

Alleles↗