PubMed Health⌕ Search

Biomedical subjects

C N Pronk

Publications and source records attributed to C N Pronk.

6 recordsLinked to original sources

Comparison between EMG to force processing and kinetic analysis for the calf muscle moment in walking and stepping.

In EMG to force processing the force of a muscle or the corresponding muscle moment with respect to the joint is determined from EMG and muscle length by means of a model of the muscle's contractile and elastic properties. In kinetic analysis the joint moment is calculated from the ground reaction force and the positions and accelerations of the body segments by means of Newtonian equations, based on a rigid body segment model. These two fundamentally different methods have been compared by determining simultaneously the calf muscle moment and the total ankle moment in walking at slow, moderate and fast speed and in stepping up and down a low bench. As long as there is no activity of other muscles, the moments obtained by either method should be identical. The analysis was restricted to such periods, as assessed from the EMG of tibialis anterior. In each experimental condition three steps were analyzed in five subjects of 21-22 yr. In comparison with the results of kinetic analysis, EMG processing shows differences between 7 and 54 Nm r.m.s., with an average of 22 Nm r.m.s. Normalized with respect to the r.m.s. value of the moment itself, the differences amount to 0.13-0.51, with an average of 0.22. In the majority of cases there was no systematic deviation between EMG processing and kinetic analysis and the r.m.s. difference was of the same order of magnitude as determined previously in ergometer experiments.

Biomechanical Phenomena↗

Electric wheelchair simulator as a man-machine system.

The procedure for adapting an electric wheelchair for use by a particular patient has not yet been perfected. This paper describes an attempt to improve this procedure with the aid of computer-aided simulation and must be regarded as a pilot study. In this simulation a bird's-eye view of the movement of the wheelchair is represented on the screen of a display terminal. A procedure that had been worked out beforehand was tested on 16 subjects, including 4 patients who came into consideration for an electric wheelchair. Some procedural and task-oriented parameters were investigated. The discussion deals with forms of simulation and the particular influences on the learning effect, among other things. It is concluded that the simulator described may be a useful aid in the evaluation or adaptation of electric wheelchairs, though it does not give all the information needed. Further research is required.

Adolescent↗

A method for two dimensional multi-segmental kinematic and kinetic analysis of normal and pathological human gait.

The application of an integrated gait analysis system in clinical research is described. With this system it is possible to analyse the walking pattern of various groups of patients with regard to foot-floor contact, kinematics and kinetics, using a Selspot system. In order to study various groups of patients an extensive body-segment model adapted to the variety in patient groups is dealt with and is related to data from the literature. Special attention has been paid to the analysis or errors in the quantities used in kinematics and kinetics. The various sources of errors leading to inaccuracy of the data describing the walking pattern are discussed.

Biomechanical Phenomena↗