PubMed Health⌕ Search

Biomedical subjects

C Nauraye

Publications and source records attributed to C Nauraye.

12 recordsLinked to original sources

[Results of proton beam irradiation for treatment of choroidal melanoma].

PURPOSE: To evaluate the results of proton beam irradiation of choroidal melanomas on a large series of patients. PATIENTS AND METHODS: Retrospective analysis of a series of patients treated with proton beam irradiation between 1991 and December 1998. The data were analyzed to evaluate the local tumor control as well as the general progression and metastatic rate of the patients. Statistical analysis served to isolate risk factors for relapse or metastasis. RESULTS: We treated 1062 patients during the study period, with a median follow-up of 38 months. Local control was obtained for 97.1% of the patients. Tumors anterior to the equator were at risk for relapse. The survival rate was 92% at 2 years and 78% at 5 years. 73.1% of the 1062 patients died from metastasis, 6.1% of living patients presented with metastatic disease. The risk factors for death were the initial diameter, the age of the patient, and large tumor volume at diagnosis. Metastasis were essentially hepatic (94.6%). Risk factors for metastasis were: a large tumor volume, a lesion anterior or straddling the equator and the age of the patient. Ocular complications may induce a visual loss of 0.1 and less in 47% of the patients, due to optic nerve head and macular ischemia. 6% of the patients required secondary enucleation due to local complications (neovascular glaucoma). CONCLUSION: Proton beam irradiation of choroidal melanoma allows good tumor control and eye retention. The survival prognosis is associated with the initial volume of the tumor. The functional results may be improved and new therapeutics are needed to treat metastatic disease.

Adolescent↗

Experimental determination and verification of the parameters used in a proton pencil beam algorithm.

We present an experimental procedure for the determination and the verification under practical conditions of physical and computational parameters used in our proton pencil beam algorithm. The calculation of the dose delivered by a single pencil beam relies on a measured spread-out Bragg peak, and the description of its radial spread at depth features simple specific parameters accounting individually for the influence of the beam line as a whole, the beam energy modulation, the compensator, and the patient medium. For determining the experimental values of the physical parameters related to proton scattering, we utilized a simple relation between Gaussian radial spreads and the width of lateral penumbras. The contribution from the beam line has been extracted from lateral penumbra measurements in air: a linear variation with the distance collimator-point has been observed. Analytically predicted radial spreads within the patient were in good agreement with experimental values in water under various reference conditions. Results indicated no significant influence of the beam energy modulation. Using measurements in presence of Plexiglas slabs, a simple assumption on the effective source of scattering due to the compensator has been stated, leading to accurate radial spread calculations. Dose measurements in presence of complexly shaped compensators have been used to assess the performances of the algorithm supplied with the adequate physical parameters. One of these compensators has also been used, together with a reference configuration, for investigating a set of computational parameters decreasing the calculation time while maintaining a high level of accuracy. Faster dose computations have been performed for algorithm evaluation in the presence of geometrical and patient compensators, and have shown good agreement with the measured dose distributions.

Algorithms↗

Intraocular inflammation after proton beam irradiation for uveal melanoma.

AIM: To describe the inflammatory reaction that can occur following proton beam irradiation of uveal melanomas based on a large series of patients and to try to determine the risk factors for this reaction. METHODS: Data from a cohort of patients with uveal melanoma treated by proton beam irradiation between 1991 and 1994 were analysed. The presence of inflammation was recorded and evaluated. Kaplan-Meier estimates and statistical analysis of general and tumour related risk factors were performed. RESULTS: 28% of patients treated during this period presented with ocular inflammation (median follow up 62 months). Risks factors were essentially tumour related and were correlated with larger lesions (height > 5 mm, diameter > 12 mm, volume > 0.4 cm(3)). Multivariate analysis identified initial tumour height and irradiation of a large volume of the eye as the two most important risk factors. Ocular inflammation usually consisted of mild anterior uveitis, resolving rapidly after topical steroids and cycloplegics. The incidence of inflammation after proton beam irradiation of melanomas seems higher than previously reported and is related to larger lesions. Evidence of inflammation associated with uveal melanoma has been described and seems to be associated with tumour necrosis (spontaneous or after irradiation). The appearance of transient inflammation during the follow up of these patients may be related to the release of inflammatory cytokines during tumour necrosis. CONCLUSION: Inflammation following proton beam irradiation is not unusual. It is correlated with larger initial tumours and may be related to tumour necrosis.

Analysis of Variance↗

[Optic neuropathy after proton-beam therapy for malignant choroidal melanoma].

Proton-beam irradiation is a conservative therapy commonly used for the treatment of uveal malignant melanomas. Some adverse effects such as optic neuropathy can compromise the visual outcome. We were interested in determining the risk factors for radiation papillopathy. Since there is currently no effective therapy, this is an interesting way to improve prevention of optic neuropathy. Six hundred sixty-two eyes had more than 24 month follow-up after proton-beam irradiation for uveal melanoma. In five hundred twenty-two cases, the clinical examination of the optic nerve head by ophthalmoscopy was possible. One-hundred eleven optic discs were pathologic, whereas 411 remained disease-free. Retrospective study of these two groups allowed to quantify the risk factors for optic neuropathy. The irradiation of more than 2mm of optic nerve at 30 Grays-equivalents appeared to be the major risk factor for optic neuropathy. For a given irradiation dose, the observed pattern of clinical responses was heterogeneous. These results are discussed and compared to the previous published reports. Visual results and life prognosis are also discussed, considering the optic nerve head status. Proton-beam therapy can preserve the optic nerve when the tumor location allows to keep it away from the irradiation-field. Patients must be informed about the risk of optic neuropathy after proton-beam irradiation.

Choroid Neoplasms↗

A preliminary comparative treatment planning study for radiotherapy of age-related maculopathy.

PURPOSE: We present a comparative planning of different approaches for external radiotherapy in age-related maculopathies. MATERIALS AND METHODS: Calculated dose distributions and dose-volume histograms for (a) bilateral irradiation with 6 MV photons, (b) a single lateral-oblique beam using either photons, electrons or protons and (c) an anterior circular proton beam. RESULTS: For lateral photon or electron beams the dose to the lens is usually lower than 10% of the dose to the macula. The entrance doses for bilateral photon beams are about 50% which increase up to 100% at the orbital bone. About 5 mm of optic nerves are irradiated at the maximal dose while the optic chiasma is spared. A single photon beam gives 50% of the dose to the fellow eye. The electron beam spares the fellow eye but gives a rather inhomogeneous dose to the target volume. For a lateral proton beam, 4 mm of optic nerve receives 90% of the dose, the skin dose is at least 70% of the dose to the macula and the lens and the fellow eye are spared. An anterior proton beam gives 90% of the dose to 1 mm of optic nerve and the 50% isodose approaches the periphery of the lens. CONCLUSION: Doses to the critical structures can be dramatically diminished for all the techniques by reducing the beam size, but only if very precise set-up techniques are used. Proton beams are an attractive solution, but the impact of such a choice on the use of proton facilities and on the national health system should be carefully evaluated, as well as the risk of radio-induced secondary neoplasias.

Humans↗

Proton dosimetry comparison involving ionometry and calorimetry.

A comparison of the absorbed dose to tissue determined by various ionization chambers, Faraday cups, and an A-150 plastic calorimeter was performed in the 200 MeV proton beam of Orsay, France. Four European proton-therapy centers (Clatterbridge, UK, Louvain la Neuve, Belgium, and Nice and Orsay, France) participated in the comparison. An agreement of better than 1% was observed in the absorbed dose to A-150 measured with the different chambers of the participating groups. The mean ratio of the absorbed dose to A-150 determined with the calorimeter to that determined by the different ionization chambers in the different irradiation conditions was found to be 0.952 +/- 0.007 [1 standard deviation (SD)] according to the code of practice used by all the participating centers, based on Janni's tables of stopping powers and a value of 35.2 J/Coulomb for (W(air)/e)p. A better agreement in the mean ratio calorimeter/chamber, 0.985 +/- 0.007 (1 SD) is observed when using the proton stopping power ratio values recently published by the International Commission on Radiation Units and Measurements in Report no. 49. The mean ratio of these doses determined in accordance with the American Association of Physicists in Medicine protocol and using the new recommended stopping power tables becomes 1.002 +/- 0.007 (1 SD). Two Faraday cups agree in measured charge to within 0.8%; however, the calculation of dose is underestimated by up to 17%; compared with ion chamber measurements and seems to be very sensitive to measurement conditions, particularly to the distance to the collimator.

Calibration↗

[Initial results of proton therapy in choroidal melanoma at the d'Orsey Center for Proton Therapy; the first 464 cases].

PURPOSE: Retrospective analysis of the treatment of choroidal melanoma with protontherapy at the Centre de protonthérapie d'Orsay, France. PATIENTS AND METHODS: Between September 1991 and September 1995, 612 patients presenting with choroidal melanoma were treated by protontherapy in Orsay. Following initial management of the first 464 patients, results were analyzed, as were results after a 1-year follow-up for 305 patients, a 2-year follow-up for 169 patients, and a 3-year follow-up for 59 patients. RESULTS: Univariate analysis showed that the actuarial local recurrence rate was 5%, the 3-year survival rate 88%, and the overall metastasic rate 5%. The initial tumor volume was the most significant predictive factor for visual results and metastases. Multivariate analysis revealed that visual results were significantly related to the initial tumor volume, initial retinal detachment, and total dose delivered to the optic nerve and macula. CONCLUSION: Protontherapy of choroidal melanoma allows in most cases conservation of the eye without modification of survival. Visual results mainly depend on the site and size of the tumor.

Choroid Neoplasms↗

A model for the lateral penumbra in water of a 200-MeV proton beam devoted to clinical applications.

An experimental approach for modeling the lateral penumbra of a proton beam has been investigated. Measurements were made with a silicon diode in a water tank. Several geometrical configurations (phantom position, collimator-to-surface distance, collimator diameter, bolus thickness, air gap, etc.) and beam characteristics (range, modulation, etc.) have been studied. The results show that the lateral penumbra is almost independent of the beam modulation and the diameter of the collimator. The use of scaled variables for depth and penumbra allows us to represent the increase in penumbra with depth for any configuration with a second order polynomial function, provided that the penumbra at the entrance of the medium and at the depth of the range are known.

Biophysical Phenomena↗

An experimental approach to the design of a scattering system for a proton therapy beam line dedicated to ophthalmological applications.

PURPOSE: The development of a scattering system for a proton therapy beam line dedicated to ophthalmological applications. METHODS AND MATERIALS: A protontherapy beam line has been developed for the treatment of uveal melanoma at the Orsay synchrocyclotron. The original 200 MeV proton beam is degraded to 76 MeV and the final beam characteristics (range, modulation, flatness, collimation) are obtained with beam modifiers in the treatment room. A passive scattering system is used to obtain a uniform dose distribution in the beam cross-section throughout 30 mm in diameter, with minimal losses in energy and dose rate. We have used an experimental approach for the scattering study. RESULTS: An elliptical ring shaped from 0.1-mm thick lead is the solution we have adopted for the scattering system. For a modulated beam, a flatness of 1% is obtained on transverse profiles. The energy loss introduced by this scatterer is only 0.5 MeV, with no appreciable change in the range over the treatment field. For an unmodulated beam, 21% of intensity is lost when the scatterer is used. The distal and the lateral dose fall-off (90-10%) for a modulated beam are 2.6 mm. These last values are independent of the range and the modulation currently used for the ophthalmic applications. CONCLUSION: A specific passive scattering system can be adapted to a particular beam emittance. A systematic experimental approach can easily be undertaken to obtain the scatterer adapted for small irradiation fields in proton therapy.

Equipment Design↗