PubMed Health⌕ Search

Biomedical subjects

C Nistor

Publications and source records attributed to C Nistor.

At least 19 recordsLinked to original sources

Nonlinear domain-wall velocity enhancement by spin-polarized electric current.

The interaction between a dc spin-polarized electric current and a magnetic domain wall in a Permalloy nanowire was studied by high-bandwidth scanning Kerr polarimetry. The full functional dependence of wall velocity on electric current and magnetic field is presented. With the pinning potential nulled by a field, current-induced velocity enhancements exceeded 35 m/s at a current density of approximately 6 x 10(11) A/m(2). This large enhancement, more than 10 times that found in pinning-dominated experiments, results in part from an interaction that is nonlinear in current and independent of current direction.

Journal Article↗

GDH biosensor based off-line capillary immunoassay for alkylphenols and their ethoxylates.

The application of a quinoprotein glucose dehydrogenase modified thick-film sensor as label detector in a capillary immunoassay (CIA) for xenoestrogens is presented. The detection of the alkylphenols and their ethoxylates is based on the competition between the analyte and tracer molecules for the binding sites of anti-alkylphenol ethoxylate antibodies. This assay is performed off-line in small disposable PVC capillaries coated with immobilized antibodies. This format allows the combination of the assay with a small portable device potentially useful for on-site environmental monitoring. Beside high amplification the utilization of beta-galactosidase as enzyme label allows the direct combination with a GDH biosensor at optimal pH conditions. The bioelectrocatalytic properties of this biosensor offer an additional amplification and thus allow a very sensitive quantification of 4-aminophenol, generated by the beta-galactosidase. Detection limits of the analytes in the microg/l range were obtained, while other phenolics and surfactants showed no or very little cross reactivity.

Biosensing Techniques↗

Detection of Escherichia coli in water by culture-based amperometric and luminometric methods.

The application of amperometric biosensor- and chemiluminiscence based methods for rapid detection of viable E. coli in water has been investigated. An amplification of the amperometric signal by a factor of 4 was obtained when the cellobiose dehydrogenase (CDH) biosensor was used instead of a plain graphite electrode for detection of b-galactosidase (b-GAL) activity at 22.5 degrees C. A linear correlation was demonstrated for detection time (DT) vs. initial concentrations (logarithmic units) of E. coli IT1 and E. coli in environmental samples, respectively, by use of the CDH biosensor or a chemiluminometric technique. The study has shown that an E. coli concentration > or = 10(4) cfu/100 mL in environmental samples was determined by the CDH biosensor within one working day. However, further reduction of the DT can be obtained, e.g. by increasing the signal amplification factor using other biosensors.

Biosensing Techniques↗

Antibody-based methods for surfactant screening.

This brief overview summarises the immunoassay-based results obtained in the course of two years of the European INCO-Copernicus project BIOTOOLS. The project is aimed at simplifying the procedures for detection of surface active compounds (SAC) using, among others, antibody-based methods, i.e., microtiter plate-based enzyme-linked immunosorbent assays (ELISA), polarisation fluoro immunoassays (PFIA), and enzyme flow injection immunoassays (FIIA). Thirty-three rabbits were immunised with five different sulphophenyl moieties and three p-hydroxyphenyl moieties conjugated to protein immunogens to produce analytical antibodies against linear alkylbenzene sulphonates (LAS) and nonylphenol (NP). Although most of the antibodies exhibited binding reaction in indirect ELISA, only a few showed the required assay sensitivity. The best antibodies for LAS exhibited a 50% binding inhibition at IC50 19.8 microg L(-1) in indirect ELISA. Similar inhibition was observed for direct ELISA using peroxidase tracers. Antibodies against NP allowed the establishment of an indirect assay operating in the mg L(-1) range. A rapid and simple protocol for the screening of NP and LAS using homogeneous PFIA is described. The assay time for 10 samples was 7 minutes, thus allowing fast detection of the selected SAC at the mg L(-1) level. A generic competitive FIIA system, using a protein G column for separation of free and antibody-bound beta-galactosidase (beta-Gal) tracer, was developed for the screening of LAS, NP, and nonylphenol decaethoxylate (NPEO10). The FIIA had a sample throughput (STP) of 5-10 samples per hour, with limits of detection (LOD) for LAS, NP, and NPEO10 of 19.5, 52, and 2.4 microg L(-1), respectively. The developed FIIAs were applied to spiked rain and surface water.

Animals↗

Electrooxidation mechanism of biogenic amines at amine oxidase modified graphite electrode.

Amine oxidase (AO, EC. 1.4.3.6) was previously shown to be a very efficient biological recognition element of amperometric biosensors for monitoring biogenic amines. The enzyme was effectively working in both mono- and bienzyme electrode designs, based on either a direct or a mediated electron-transfer pathway. This work focuses on the elucidation of the electron-transfer mechanism of the monoenzymatic unmediated AO-modified biosensor. The observed unmediated catalytic currents were assumed to be caused by (i) a direct electron-transfer process, (ii) the electrooxidation of the formed product, or (iii) their combination. Experiments supporting these assumptions are discussed in detail.

Amine Oxidase (Copper-Containing)↗

An enzyme flow immunoassay that uses beta-galactosidase as the label and a cellobiose dehydrogenase biosensor as the label detector.

The aim was to develop a fast generic enzyme flow immunoassay (EFIA) using a beta-galactosidase (beta-GAL) label in combination with colorimetric detection as well as with a new amperometric biosensor as the label detector. The amperometric biosensor was previously developed within the group for the determination of diphenols in surface water samples. Antigen (Ag, analyte), tracer (Ag*, antigen labeled with beta-GAL), and antibody (Ab) were incubated off-line. After the equilibrium was reached, the sample was introduced into the flow system. The antibody complexes, AgAb and Ag*Ab, were trapped in a protein G column while the free unbound tracer was eluted and detected by an amperometric biosensor downstream after substrate reaction. The enzyme label beta-GAL converted the substrate 4-aminophenyl-beta-D-galactopyranoside (4-APG) into 4-aminophenol (4-AP), which subsequently was detected by a cellobiose dehydrogenase (CDH) modified solid graphite electrode. 4-AP was first oxidized at the electrode surface at +300 mV vs Ag/AgCl, and the formed 4-imino quinone (4-IQ) was reduced back to 4-AP by the CDH in the presence of cellobiose. By combining the EFIA with the CDH biosensor, the overall signal of one tracer molecule is amplified at two occasions, i.e., one enzyme label converts the substrate into many 4-AP molecules, and second these are further amplified by the CDH biosensor. The optimum conditions for the EFIA in terms of the molar ratio between tracer and beta-GAL, temperature, flow rate, etc., was investigated with colorimetric detection, using 2-nitrophenyl-beta-D-galactopyranoside (2-NPG) as the beta-GAL substrate. The performance of both the colorimetric and CDH biosensor detection was investigated and both methods were applied for determination of the model compound atrazine in spiked surface water samples. Detection limits of 0.056 +/- 0.008 and 0.038 +/- 0.007 microg L(-1) and IC50 values of 2.04 +/- 0.294 and 0.42 +/- 0.08 microg L(-1) were obtained for colorimetric and CDH detection, respectively. Matrix effects were less pronounced with the CDH biosensor than with colorimetric detection.

Biosensing Techniques↗

Inter-laboratory comparison of liquid chromatographic techniques and enzyme-linked immunosorbent assay for the determination of surfactants in wastewaters.

Seven laboratories participated in an inter-laboratory comparison exercise within the framework of the PRISTINE, SANDRINE and INEXsPORT European Union Projects. Solid-phase extraction (SPE) methodologies were used for the extraction of target analytes from wastewaters. The analytical strategies were based on liquid chromatography (LC) coupled to mass spectrometric (MS) or to fluorescent (FL) detection in all cases with the exception of one laboratory using a test-tube enzyme-linked immunosorbent assay kit. Samples were spiked with the surfactants nonylphenolpolyglycol ether, coconut diethanolamide, linear alkylbenzene sulfonate, nonylphenolpolyglycol ether sulfate, alkylpolyglycol ether and secondary alkane sulfonate. After enrichment on previously conditioned SPE cartridges, the SPE cartridges were distributed among the participating laboratories without the information about the amount of spiked surfactants. In addition, SPE cartridges loaded with a real-world environmental sample containing a tannery wastewater were also analyzed. The results of the programme showed that SPE followed by LC-MS techniques are reliable for the surfactants determination at submicrogram to microgram per liter levels in wastewaters. Inter-laboratory precision values were calculated as the reproducibility relative standard deviation (RSD(R)) which was determined from the reproducibility standard deviation (sR) and the average concentration at a particular concentration level. When data from all laboratories were pooled, the RSD(R) values ranged from 5.1 to 28.3% for the determination of target analytes. The most accurate result corresponded to that given for linear alkylbenzene sulfonates. Taking into account that different methodologies were used (including non-chromatographic techniques) and the complexity of the samples analyzed, it can be considered that acceptable reproducibility values were obtained in this inter-laboratory study.

Chromatography, Liquid↗

Redox hydrogel-based amperometric bienzyme electrodes for fish freshness monitoring

This work presents the design and optimization of amperometric biosensors for the determination of biogenic amines (e.g., histamine, putrescine, cadaverine, tyramine, cystamine, agmatine, spermidine), commonly present in food products, and their application for monitoring of freshness in fish samples. The biosensors were used as the working electrodes of a three-electrode electrochemical cell of wall-jet type, operated at -50 mV vs Ag/AgCl, in a flow injection system. Two different bienzyme electrode designs were considered, one based on the two enzymes [a newly isolated and purified amine oxidase (AO) and horseradish peroxidase (HRP)] simply adsorbed onto graphite electrodes, and one when they were cross-linked to an Os-based redox polymer. The redox hydrogel-based biosensors showed better biosensors characteristics, i.e., sensitivity of 0.194 A M-1 cm-2 for putrescine and 0.073 A M-1 cm-2 for histamine, and detection limits (calculated as three times the signal-to-noise ratio) of 0.17 microM for putrescine and 0.33 microM for histamine. The optimized redox hydrogel-based biosensors were evaluated in terms of stability and selectivity, and were used for the determination of total amine content in fish samples kept for 10 days in different conditions.

Journal Article↗