PubMed Health⌕ Search

Biomedical subjects

C O S Sorzano

Publications and source records attributed to C O S Sorzano.

9 recordsLinked to original sources

A novel method for improvement of visualization of power spectra for sorting cryo-electron micrographs and their local areas.

In a context of automation of cryo-electron microscopy, we developed a novel method for improving visibility of diffraction rings in the power spectra of cryo-electron micrographs of vitreous ice (without carbon film or high concentration of diffracting material). We used these enhanced spectra to semi-automatically detect and remove micrographs and/or local areas introducing errors in the global 3D map (drifted and charged areas) or those unable to increase global signal-to-noise ratio (non-diffracting areas). Our strategy also allows a detection of micrographs/areas with a strong astigmatism. These images should be removed when using algorithms that do not correct astigmatism. Our sorting method is simple and fast since it uses the normalized cross-correlation between enhanced spectra and their copies rotated by 90 degrees. It owes its success mainly to the novel pre-processing of power spectra. The improved visibility also allows an easier visual check of accuracy of sorting. We show that our algorithm can even improve the visibility of diffraction rings of cryo-electron micrographs of pure water. Moreover, we show that this visibility depends strongly on ice thickness. This algorithm is implemented in the Xmipp (open-source image processing package) and is freely available for implementation in any other software package.

Algorithms↗

Spline-based image-to-volume registration for three-dimensional electron microscopy.

This paper presents an algorithm based on a continuous framework for a posteriori angular and translational assignment in three-dimensional electron microscopy (3DEM) of single particles. Our algorithm can be used advantageously to refine the assignment of standard quantized-parameter methods by registering the images to a reference 3D particle model. We achieve the registration by employing a gradient-based iterative minimization of a least-squares measure of dissimilarity between an image and a projection of the volume in the Fourier transform (FT) domain. We compute the FT of the projection using the central-slice theorem (CST). To compute the gradient accurately, we take advantage of a cubic B-spline model of the data in the frequency domain. To improve the robustness of the algorithm, we weight the cost function in the FT domain and apply a "mixed" strategy for the assignment based on the minimum value of the cost function at registration for several different initializations. We validate our algorithm in a fully controlled simulation environment. We show that the mixed strategy improves the assignment accuracy; on our data, the quality of the angular and translational assignment was better than 2 voxel (i.e., 6.54 angstroms). We also test the performance of our algorithm on real EM data. We conclude that our algorithm outperforms a standard projection-matching refinement in terms of both consistency of 3D reconstructions and speed.

Algorithms↗

Spectral signal-to-noise ratio and resolution assessment of 3D reconstructions.

Measuring the quality of three-dimensional (3D) reconstructed biological macromolecules by transmission electron microscopy is still an open problem. In this article, we extend the applicability of the spectral signal-to-noise ratio (SSNR) to the evaluation of 3D volumes reconstructed with any reconstruction algorithm. The basis of the method is to measure the consistency between the data and a corresponding set of reprojections computed for the reconstructed 3D map. The idiosyncrasies of the reconstruction algorithm are taken explicitly into account by performing a noise-only reconstruction. This results in the definition of a 3D SSNR which provides an objective indicator of the quality of the 3D reconstruction. Furthermore, the information to build the SSNR can be used to produce a volumetric SSNR (VSSNR). Our method overcomes the need to divide the data set in two. It also provides a direct measure of the performance of the reconstruction algorithm itself; this latter information is typically not available with the standard resolution methods which are primarily focused on reproducibility alone.

Algorithms↗

Phan3D: design of biological phantoms in 3D electron microscopy.

Three-Dimensional Electron Microscopy (3DEM) has turned out to be a major player in structural proteomics. In 3DEM, tens of thousands of EM images from a macromolecule at different views are combined to derive its structure by means of a 3D reconstruction algorithm. However, for an optimal reconstruction, the most suitable algorithm has to be used and its parameters have to be tuned for the macromolecule under study and the experimental conditions found. The use of phantoms is central to objective comparison of reconstruction algorithms and optimization of their parameters. Phan3D is a tool intended to provide a fully visual and interactive environment that facilitates the design of phantoms resembling biological specimens in 3DEM. Phan3D has been developed as an alternative to the tedious, error-prone and old-fashioned phantom design that is based on hand-written text description files.

Computer Graphics↗

Transfer function restoration in 3D electron microscopy via iterative data refinement.

Three-dimensional electron microscopy (3D-EM) is a powerful tool for visualizing complex biological systems. As with any other imaging device, the electron microscope introduces a transfer function (called in this field the contrast transfer function, CTF) into the image acquisition process that modulates the various frequencies of the signal. Thus, the 3D reconstructions performed with these CTF-affected projections are also affected by an implicit 3D transfer function. For high-resolution electron microscopy, the effect of the CTF is quite dramatic and limits severely the achievable resolution. In this work we make use of the iterative data refinement (IDR) technique to ameliorate the effect of the CTF. It is demonstrated that the approach can be successfully applied to noisy data.

Algorithms↗

A multiresolution approach to orientation assignment in 3D electron microscopy of single particles.

Three-dimensional (3D) electron microscopy (3DEM) aims at the determination of the spatial distribution of the Coulomb potential of macromolecular complexes. The 3D reconstruction of a macromolecule using single-particle techniques involves thousands of 2D projections. One of the key parameters required to perform such a 3D reconstruction is the orientation of each projection image as well as its in-plane orientation. This information is unknown experimentally and must be determined using image-processing techniques. We propose the use of wavelets to match the experimental projections with those obtained from a reference 3D model. The wavelet decomposition of the projection images provides a framework for a multiscale matching algorithm in which speed and robustness to noise are gained. Furthermore, this multiresolution approach is combined with a novel orientation selection strategy. Results obtained from computer simulations as well as experimental data encourage the use of this approach.

Algorithms↗

XMIPP: a new generation of an open-source image processing package for electron microscopy.

X-windows based microscopy image processing package (Xmipp) is a specialized suit of image processing programs, primarily aimed at obtaining the 3D reconstruction of biological specimens from large sets of projection images acquired by transmission electron microscopy. This public-domain software package was introduced to the electron microscopy field eight years ago, and since then it has changed drastically. New methodologies for the analysis of single-particle projection images have been added to classification, contrast transfer function correction, angular assignment, 3D reconstruction, reconstruction of crystals, etc. In addition, the package has been extended with functionalities for 2D crystal and electron tomography data. Furthermore, its current implementation in C++, with a highly modular design of well-documented data structures and functions, offers a convenient environment for the development of novel algorithms. In this paper, we present a general overview of a new generation of Xmipp that has been re-engineered to maximize flexibility and modularity, potentially facilitating its integration in future standardization efforts in the field. Moreover, by focusing on those developments that distinguish Xmipp from other packages available, we illustrate its added value to the electron microscopy community.

Algorithms↗

Normalizing projection images: a study of image normalizing procedures for single particle three-dimensional electron microscopy.

In the process of three-dimensional reconstruction of single particle biological macromolecules several hundreds, or thousands, of projection images are taken from tens or hundreds of independently digitized micrographs. These different micrographs show differences in the background grey level and particle contrast and, therefore, have to be normalized by scaling their pixel values before entering the reconstruction process. In this work several normalization procedures are studied using a statistical comparison framework. We finally show that the use of the different normalization methods affects the reconstruction quality, providing guidance on the choice of normalization procedures.

Algorithms↗

A method for estimating the CTF in electron microscopy based on ARMA models and parameter adjustment.

In this work, a powerful parametric spectral estimation technique, 2D-auto regressive moving average modeling (ARMA), has been applied to contrast transfer function (CTF) detection in electron microscopy. Parametric techniques such as auto regressive (AR) and ARMA models allow a more exact determination of the CTF than traditional methods based only on the Fourier transform of the complete image or parts of it and performing some average (periodogram averaging). Previous works revealed that AR models can be used to improve CTF estimation and the detection of its zeros. ARMA models reduce the model order and the computing time, and more interestingly, achieve increased accuracy. ARMA models are generated from electron microscopy (EM) images, and then a stepwise search algorithm is used to fit all the parameters of a theoretical CTF model in the ARMA model previously calculated. Furthermore, this adjustment is truly two-dimensional, allowing astigmatic images to be properly treated. Finally, an individual CTF can be assigned to every point of the micrograph, by means of an interpolation at the functional level, provided that a CTF has been estimated in each one of a set of local areas. The user need only know a few a priori parameters of the experimental conditions of his micrographs, for turning this technique into an automatic and very powerful tool for CTF determination, prior to CTF correction in 3D-EM. The programs developed for the above tasks have been integrated into the X-Windows-based Microscopy Image Processing Package (Xmipp) software package, and are fully accessible at www.biocomp.cnb.uam.es.

Algorithms↗