PubMed Health⌕ Search

Biomedical subjects

C Odet

Publications and source records attributed to C Odet.

3 recordsLinked to original sources

The SIMRI project: a versatile and interactive MRI simulator.

This paper gives an overview of SIMRI, a new 3D MRI simulator based on the Bloch equation. This simulator proposes an efficient management of the T2* effect, and in a unique simulator integrates most of the simulation features that are offered in different simulators. It takes into account the main static field value and enables realistic simulations of the chemical shift artifact, including off-resonance phenomena. It also simulates the artifacts linked to the static field inhomogeneity like those induced by susceptibility variation within an object. It is implemented in the C language and the MRI sequence programming is done using high level C functions with a simple programming interface. To manage large simulations, the magnetization kernel is implemented in a parallelized way that enables simulation on PC grid architecture. Furthermore, this simulator includes a 1D interactive interface for pedagogic purpose illustrating the magnetization vector motion as well as the MRI contrasts.

Algorithms↗

Two-dimensional spatial and temporal displacement and deformation field fitting from cardiac magnetic resonance tagging.

Tagged magnetic resonance imaging is a specially developed technique to noninvasively assess contractile function of the heart. Several methods have been developed to estimate myocardial deformation from tagged image data. Most of these methods do not explicitly impose a continuity constraint through time although myocardial motion is a continuous physical phenomenon. In this paper, we propose to model the spatio-temporal myocardial displacement field by a cosine series model fitted to the entire tagged dataset. The method has been implemented in two dimensions (2D)+time. Its accuracy was successively evaluated on actual tagged data and on a simulated two-dimensional (2D) moving heart model. The simulations show that an overall theoretical mean accuracy of 0.1 mm can be attained with adequate model orders. The influence of the tagging pattern was evaluated and computing time is provided as a function of the model complexity and data size. This method provides an analytical and hierarchical model of the 2D+time deformation inside the myocardium. It was applied to actual tagged data from a healthy subject and from a patient with ischemia. The results demonstrate the adequacy of the proposed model for this evaluation.

Computer Simulation↗

A synchrotron radiation microtomography system for the analysis of trabecular bone samples.

X-ray computed microtomography is particularly well suited for studying trabecular bone architecture, which requires three-dimensional (3-D) images with high spatial resolution. For this purpose, we describe a three-dimensional computed microtomography (microCT) system using synchrotron radiation, developed at ESRF. Since synchrotron radiation provides a monochromatic and high photon flux x-ray beam, it allows high resolution and a high signal-to-noise ratio imaging. The principle of the system is based on truly three-dimensional parallel tomographic acquisition. It uses a two-dimensional (2-D) CCD-based detector to record 2-D radiographs of the transmitted beam through the sample under different angles of view. The 3-D tomographic reconstruction, performed by an exact 3-D filtered backprojection algorithm, yields 3-D images with cubic voxels. The spatial resolution of the detector was experimentally measured. For the application to bone investigation, the voxel size was set to 6.65 microm, and the experimental spatial resolution was found to be 11 microm. The reconstructed linear attenuation coefficient was calibrated from hydroxyapatite phantoms. Image processing tools are being developed to extract structural parameters quantifying trabecular bone architecture from the 3-D microCT images. First results on human trabecular bone samples are presented.

Aged↗