PubMed Health⌕ Search

Biomedical subjects

C Ortíz

Publications and source records attributed to C Ortíz.

4 recordsLinked to original sources

Hydrophilic polymers derived from vitamin E.

Vitamin E containing copolymers for biomedical applications was obtained by copolymerization reaction of vitamin E methacrylate (VEMA) with 2-hydroxyethyl methacrylate (HEMA), N,N-dimethyl acrylamide (DMA) or vinyl pyrrolidone (VP), in different experiments. High molecular weight copolymers prepared by free radical reactions initiated by azobisisobutironitrilo, AIBN, present a random distribution of vitamin E derivatives along the macromolecular chains, and the average composition depends on the initial composition of the reaction medium. The relative flexibility of the polymeric systems was analyzed measuring the glass transition temperature of copolymeric sequences and that of the pure alternating diad (Tg12) obtained by the application of the treatments proposed by Johnston and Barton to all the systems. Tg12 was higher than the average T of both homopolymers (Tg) for the VEMA-HEMA system, Tg12 was lower than Tg for the VEMA-DMA system and Tg12 was similar to Tg for the VEMA-VP system. VEMA-HEMA copolymers gave rise to hydrogels in water, acidic and alkaline media. VEMA-DMA copolymers gave rise to hydrogels in acidic medium and dissolved in water and alkaline medium. VEMA-VP copolymers were soluble in all media. The swelling of all the hydrogels fit a second order kinetics. A VEMA-HEMA hydrogel was selected for in vivo experiments in order to study the influence of vitamin E on the regeneration process of Achilles tendon. The polymeric derivatives of vitamin E stimulated the regenerative process as a consequence of the antiaging effect in the local area of application.

Acrylamides↗

Hydrophilic polymers derived from vitamin E.

Vitamin E containing copolymers for biomedical applications were obtained by copolymerization reaction of vitamin E methacrylate (VEMA) with 2-hydroxyethyl methacrylate (HEMA), N,N-dimethyl acrylamide (DMA) or vinyl pyrrolidone (VP), in different experiments. High molecular weight copolymers prepared by free radical reactions initiated by azobisisobutironitrilo, AIBN, present a random distribution of vitamin E derivatives along the macromolecular chains, and the average composition depends on the initial composition of the reaction medium. The relative flexibility of the polymeric systems was analyzed measuring the glass transition temperature of copolymeric sequences and that of the pure alternating diad (Tg12) obtained by the application of the treatments proposed by Johnston and Barton to all the systems. Tg12 was higher than the average Tg of both homopolymers (Tg) for the VEMA-HEMA system, Tg12 was lower than Tg for the VEMA-DMA system and Tg12 was similar to Tg for the VEMA-VP system. VEMA-HEMA copolymers gave rise to hydrogels in water, acidic and alkaline media. VEMA-DMA copolymers gave rise to hydrogels in acidic medium and dissolved in water and alkaline medium. VEMA-VP copolymers were soluble in all media. The swelling of all the hydrogels fit a second-order kinetics. A VEMA-HEMA hydrogel was selected for in vivo experiments in order to study the influence of vitamin E on the regeneration process of Achilles tendon. The polymeric derivatives of vitamin E stimulated the regenerative process as a consequence of the antiaging effect in the local area of application.

Animals↗

An assessment of the validity of ICD Code 410 to identify hospital admissions for myocardial infarction: The Corpus Christi Heart Project.

BACKGROUND: The identification of myocardial infarction (MI) is typically based on finding events designated by a nosologist with the appropriate International Classification of Diseases (ICD) code, currently code 410. These codes are applied based on review of medical records or death certificates. However, other factors, including reimbursement considerations, may influence the coding process, especially for hospitalizations. Thus, the validity of using ICD code 410 to identify MI must be assessed. METHODS: The Corpus Christi Heart Project (CCHP) is a population-based surveillance programme for hospitalized MI. Patients were identified using concurrent ascertainment in coronary care units and retrospective review of medical records. Events were validated as definite or possible MI using data regarding chest pain, electrocardiographic changes and cardiac enzymes. The validity of using ICD code 410 to identify cases of MI was assessed by calculating the sensitivity, specificity, predictive values and efficiency of ICD code 410 versus the CCHP 'gold standard'. RESULTS: Use of ICD code 410 identified 80.9% (401/496) of definite MI, but only 19.0% (243/1280) of possible MI. Only 12.3% (90/734) of discharges with an ICD 410 code received a 'no MI' designation based on the 'gold standard'. The efficiency of ICD code 410 for identifying MI was 92.0% for definite MI and 77.1% for definite and possible MI. CONCLUSIONS: The use of ICD code 410 to identify hospitalized cases of MI results in a modestly biased overestimate of the number of definite MI hospitalizations; however, this approach warrants consideration due to the expense of validation procedures.

Adult↗

Screening for thermostability and electrophoretic red blood cell sorbitol dehydrogenase (E.C.1.1.1.14) variants.

A screening for both thermostability and electrophoretic red blood cell sorbitol dehydrogenase (RBC-SORD) variants in blood donors was performed. SORD activity in standard conditions (unheated samples) in 274 individuals was 198 +/- 38.6 mIU/g Hb. The ratio of enzymatic activity after heating (H) to the activity in controls (C) before heating (H/C ratio) was 0.39 +/- 0.10. H/C ratios minor than 0.1 in 3 out of 274 blood donors and higher than 0.9 in 1 were observed. In 208 individuals, four electrophoretic phenotypes were observed: I) Three bands, named a, b and c, with cathodic mobility in 163 individuals (78.36%); II) Two bands a and c in 25 individuals (12.02%); III) Two bands b and c in 14 (6.73%); and IV) One band, c in 6 (2.88%). Studies carried out to characterize the three bands suggest that they are isozymes of the same locus with the observation of an interchange of the bands as a normal phenomena.

Electrophoresis, Disc↗