PubMed Health⌕ Search

Biomedical subjects

C Ostiguy

Publications and source records attributed to C Ostiguy.

4 recordsLinked to original sources

Validation of a solvent-free sampler for the determination of low molecular weight aliphatic isocyanates under thermal degradation conditions.

During the thermal degradation of 1,6-hexamethylenediiso- cyanate-based (HDI) car paint, the eight most abundant isocyanates generated are isocyanic acid, methyl isocyanate, ethyl isocyanate, propyl isocyanate, butyl isocyanate, pentyl isocyanate, hexyl isocyanate, and 1,6-hexamethylenediisocyanate. For the first time, a method using solvent-free samplers is proposed and validated for the simultaneous sampling of all these isocyanates. The sampling efficiency during thermal degradation of car paint can be affected by the formation of dust and aerosols and by the emission of many chemicals, such as isocyanic acid, anhydrides, amines, and alcohols that consume the reagent or interfere in the derivatization procedure. Sampling was performed using cassettes containing two 1-(2-methoxyphenyl)piperazine (MOPIP)-coated glass fiber filters (MFs) (approximately 4.9 mg per filter) and compared with bubblers containing 15 mL of MOPIP solution in toluene (1.0 mg/mL(-1)) and with bubblers backed with MFs. A DIN 53436 laboratory scale furnace was used to generate the isocyanates under thermal degradation conditions. For an aliphatic isocyanate concentration of approximately 42 microg(NCO) m(-3), no significant difference in sampling efficiency was observed between the three techniques studied, thus confirming the sampling efficiency of the MFs. The samples were analyzed using high-performance liquid chromatography coupled with electrospray/tandem mass spectrometry. Quantification was performed in daughter mode monitoring (MOPIP+H)(+) fragments. For concentrations between 0.013 microg(NCO) mL(-1) and 0.52 microg(NCO) mL(-1) for the monoisocyanates, and between 0.026 microg(NCO) mL(-1) and 1.04 microg(NCO) mL(-1) for the HDI, the correlation coefficients were in the 0.9974-0.9996 range (n = 18). Analytical reproducibility and precision were better than 95.4% and 94.9%, respectively, for all the isocyanates. The instrumental detection limits, defined as three times the standard deviation measured at the lowest point on the calibration curve were in the 1.8-3.0 ng(NCO) mL(-1) range (n = 8), which corresponds to about 0.37-0.60 microg(NCO) m(-3) for a 15-L air sample when the filters are desorbed in 3 mL.

Air Pollutants, Occupational↗

Temperature-programmed pyrolysis hyphenated with metastable atom bombardment ionization mass spectrometry (TPPy/MAB-MS) for the identification of additives in polymers.

Thermoanalytical techniques are currently used for the analysis of additives contained in polymers that cannot be easily dissolved, extracted, or hydrolyzed. With these techniques, the polymers are heated to liberate the additives trapped in the polymer matrix. If the polymer is heated slowly, up to its thermal degradation, the technique is called temperature-programmed pyrolysis (TPPy). For TPPy experiments, mass spectrometry is generally used as the detection method. The ionization sources commonly used in mass spectrometry, such as CI and EI, can cause fragmentation during the ionization process. Fragmentation decreases the sensitivity of the molecular ions and increases the risks of interferences with the compounds coming from the matrix. An energy-tunable ionization technique, called metastable atom bombardment (MAB), is proposed for TPPy/MS experiments. With this ionization source, the energy of ionization depends on the metastable gas used. With low-energy metastable gases such as Xe or N(2), fragmentation is reduced compared to CI, whereas with medium-energy metastable gases such as Ar or Kr, the fragmentation is similar to that observed with CI. TPPy/MAB-MS was performed on an unknown polyurethane-based car paint. The detection of molecular ions and characteristic fragments with MAB(N(2)) led to the identification of two light stabilizers: Bis(1,2,2,6,6-pentamethyl-4-piperidinyl)sebacate (BPPS) and 2-(2H-benzotriazol-2-yl)-4,6- di-tert-pentylphenol (PTPP). Using MAB(Ar) to simulate CI, the molecular ion and one of the two characteristic fragments of BPPS were not detected, thus confirming the advantage of using MAB(N(2)) ionization for TPPy/MS experiments.

Journal Article↗

Visual dysfunction among styrene-exposed workers.

OBJECTIVES: The present study was undertaken to examine the relation between visual functions and occupational exposure to styrene. METHODS: A total of 128 workers (85% of the total population), from three glass-reinforced plastics plants in Canada, agreed to participate in the study. Environmental and biological measures were made on the day(s) prior to the assessment of near visual acuity (National Optical Visual Chart), chromatic discrimination (Lanthony D-15 desaturated panel), and near contrast sensitivity (Vistech 6000). The analyses were performed on 81 workers with near visual acuity of at least 1 min of arc at 0.5 m. RESULTS: The subjects were relatively young [29 (SD 8) years], with little seniority [5 (SD 4) years]. Styrene exposure for 8 h ranged from 6 to 937 (first quartile 21 mg.m-3, third quartile 303 mg.m-3), depending on the job site. The end-shift concentrations of urinary mandelic acid ranged from nondetectable to 1.90 mmol.mmol creatinine-1. Significant positive relations were found between the internal and external styrene exposure measurements and color vision loss adjusted for age, alcohol consumption, and seniority in a multiple regression analysis. The multiple regression analysis is also showed that the end-shift concentration of urinary mandelic acid was inversely related to contrast sensitivity at 6 and 12 cycles.degree-1. Logistic multiple regression models indicated that the end-shift concentration of urinary mandelic acid was related to the prevalences of blurred vision, tearing, and eye irritation. CONCLUSIONS: These findings suggest that there is a positive relation between styrene exposure and early color and contrast vision dysfunction.

Adult↗

Surveillance of early neurotoxic dysfunction.

Surveillance of early neurotoxic alterations was undertaken in 3 reinforced plastics plants, with a view to preventive intervention. Using a longitudinal study design, exposure parameters (environmental styrene in the respiratory zone of each worker and end-shift mandelic acid (MA)) and neurobehavioral performance (Neurobehavioral Core Test Battery and Field Assessment: Sensory Tests), were assessed at time zero (T0); recommendations were made to reduce exposure at jobsites with the highest risk. Reassessment was made two years later (T2). Complete exposure data was available for 118 workers at T0; 75 were still employed at T2; of these, 57 (76%) returned for testing. Those who returned had more seniority (p < 0.001) and higher MA (p < 0.01) and styrene (p < 0.05) levels at T0 than the others. Analyses, performed on the T0-T2 differences, showed improvement in exposure parameters in Plant 3, where lower levels were observed at T2 for styrene (p < 0.05) and MA (p < 0.001). workers in Plant 3 (n = 29) performed better (p < 0.05) at T2 for short term memory, perceptuo-motor speed, motor precision and manual dexterity; they reported more vigor (p < 0.05) and less anger (p = 0.07). This was not the case for the workers from the other plants. Generally, the T0-T2 difference in MA was associated (Spearman's Rho) with differences in color vision (p < 0.001), simple reaction time (mean and standard deviation), digit span forward, tension, fatigue and the number of symptoms (p < 0.05); aiming precision showed a similar tendency (p < 0.10). These findings suggest that group surveillance of early nervous system changes for jobs with exposure to neurotoxins, using a sensitive neurofunctional test battery, may be useful for preventive intervention.

Adult↗