The measurement of aerosolized endotoxin from land application of Class B biosolids in Southeast Arizona.

The purpose of this study was to determine aerosolized endotoxin concentrations downwind of a biosolids land application site. Aerosol samples were collected from biosolids land application sites, tractor operation, and an aeration basin located within an open-air wastewater treatment plant. Aerosolized endotoxin above background concentrations was detected from all sites, at levels ranging from below detection up to 1800 EU m-3 of air. Biosolids loading operations resulted in the greatest concentrations of endotoxin (mean 344 EU m-3). As downwind (perpendicular to wind vector) distance increased from sources (2-200 m), levels of endotoxin decreased to near background (without biosolids application) concentrations. Overall, the detected levels of aerosolized endotoxin were within past proposed aerosolized endotoxin limits (250-2000 EU m-3) by other occupational exposure studies. Occasionally, peak concentrations were found to be above these limits. Sites in which soil was being aerosolized resulted in greater concentrations of endotoxin with or without biosolids, which suggested that the majority of endotoxin may in fact be of soil origin. This study evaluated the presence of aerosolized endotoxin from the land application of biosolids and showed that these levels were within ranges for concern suggested by other studies and that this area of research needs further investigation.

Aerosols↗

Transport of microsporidium Encephalitozoon intestinales spores in sandy porous media.

The retention and transport of microsporidium Encephalitozoon intestinales spores in two water-saturated sandy porous media was investigated in this study. The initial breakthrough of the spores in the column effluent occurred essentially simultaneously with that of a non-reactive tracer, indicating no significant velocity enhancement. A large fraction (45-73%) of the spores injected into the columns was not recovered in the effluent, indicating removal from solution through colloid retention processes of attachment and/or straining. The relative significance of attachment and straining to total retention was evaluated in additional experiments. An experiment was conducted with a sieved coarse fraction of porous media for which straining is unlikely to be of significance based on the relative diameters of the spores and porous-medium pores. The spore recovery for this experiment was similar to the recoveries obtained for microsporidia transport in the un-sieved parent porous medium. An additional experiment was conducted with a subsample of the coarse fraction that was acid-washed to reduce potential surface attachment sites. Spore recovery was complete for this experiment. These results suggest surface deposition was the primary removal mechanism in our system. This conclusion is supported by the results of an experiment wherein deionized water was flushed through a column that was previously flushed with electrolyte solution. The effluent spore concentrations were observed to increase upon injection of deionized water, indicating re-mobilization of spores upon a change in water chemistry. The measured data were successfully simulated using a mathematical model incorporating colloid filtration. The results of this study suggest that the transport of microspordia in sandy porous media is governed by established colloid-transport processes.

Colloids↗

Estimation of bioaerosol risk of infection to residents adjacent to a land applied biosolids site using an empirically derived transport model.

AIM: The purpose of this study was to develop an empirically derived transport model, which could be used to predict downwind concentrations of viruses and bacteria during land application of liquid biosolids and subsequently assess microbial risk associated with this practice. METHODS AND RESULTS: To develop the model, coliphage MS-2 and Escherichia coli were aerosolized after addition to water within a biosolids spray application truck, and bioaerosols were collected at discrete downwind distances ranging from 2 to 70 m. Although coliphage were routinely detected, E. coli did not frequently survive aerosolization. Data on aerosolized coliphage was then used to generate a virus transport model. Risks of infection were calculated for various ranges of human virus concentrations that could be found in biosolids. CONCLUSIONS: A conservative estimate at 30.5 m (assumed to be nearest adjacent residences) downwind, resulted in risks of infection of 1 : 100,000, to the more realistic 1 : 10,000,000 per exposure. Conservative annual risks were calculated to be no more than 7 : 100,000 where as a more realistic risk was no greater than 7 : 10,000,000. Overall, the viral risk to residences adjacent to land application sites appears to be low, both for one time and annual probabilities of infection. SIGNIFICANCE AND IMPACT OF THE STUDY: This study demonstrated a simple approach towards modelling viral pathogens aerosolized from land applied liquid biosolids, and offers insight into the associated viral risk.

Agriculture↗

A national study on the residential impact of biological aerosols from the land application of biosolids.

AIMS: The purpose of this study was to evaluate the community risk of infection from bioaerosols to residents living near biosolids land application sites. METHODS AND RESULTS: Approximately 350 aerosol samples from 10 sites located throughout the USA were collected via the use of six SKC Biosamplers. Downwind aerosol samples from biosolids loading, unloading, land application and background operations were collected from all sites. All samples were analysed for the presence of HPC bacteria, total coliform bacteria, Escherichia coli, Clostridium perfringens, coliphage, enteroviruses, hepatitis A virus and norovirus. Total coliforms, E. coli, C. perfringens and coliphage were not detected with great frequency from any sites, however, biosolids loading operations resulted in the largest concentrations of these aerosolized microbial indicators. Microbial risk analyses were conducted on loading and land application operations and their subsequent residential exposures determined. CONCLUSIONS: The greatest annual risks of infection occurred during loading operations, and resulted in a 4 x 10(-4) chance of infection from inhalation of coxsackievirus A21. Land application of biosolids resulted in risks that were <2 x 10(-4) from inhalation of coxsackievirus A21. Overall bioaerosol exposure from biosolids operations poses little community risk based on this study. SIGNIFICANCE AND IMPACT OF THE STUDY: This study evaluated the overall incidence of aerosolized micro-organisms from the land application of biosolids and subsequently determined that microbial risks of infection were low for residents close to biosolids application sites.

Aerosols↗

Tracking the concentration of heterotrophic plate count bacteria from the source to the consumer's tap.

The goal of this project was to quantify the concentration of heterotrophic plate count (HPC) bacteria within water reaching consumer's taps, and from the sources used by a major utility serving the City of Tucson, AZ. With this information, the amounts and sources of HPC bacteria consumed at the tap could be determined. Samples of water were collected on a monthly basis from two well fields, the CAVSARP recovery well field and Southern Avra Valley well field which serves as one of the groundwater sources for Tucson, AZ, and the distribution system which serves the same homes from which tap water was also tested. The average concentration of HPC in source waters within Southern Avra Valley Wells was 56 CFU/ml (range 1-1995/ml). From the CAVSARP recovery well field, corresponding values were 38 CFU/ml (1 to 502 CFU/ml). Unblended groundwater in the chlorinated distribution system averaged 22 CFU/ml (range 1-794). Blended water at the chlorinated distribution site averaged 47 CFU/ml (range 10-158). There was a major shift in the percentage of gram negative to gram-positive bacteria from the wells to the distribution system, to the tap. In the surface CAP source water, 76% of the bacteria were gram-negative compared to 27% gram-negative in the CAVSARP recovery wells. In contrast, Avra Valley wells contained 17% gram-negative bacteria. In both the Tucson groundwater distribution sites and blended distribution sites, the corresponding number of gram negative bacteria was 12%. Finally at the tap, only 0.2% of the bacteria were gram-negative. The average number of bacteria in household taps averaged 3072 HPC/ml and was equal or greater than 500 ml 68% of the time. This study shows that the number of HPC bacteria increases dramatically from the distribution system to the consumers tap. Thus, the major source of bacteria ingested by the average consumer in Tucson originates from bacteria within the household distribution system or the household tap, rather than from source waters or the distribution system. It is also clear that consumers' regularly consume more than 500 HPC/ml from drinking water taken from the household tap.

Arizona↗

Bioaerosols from the land application of biosolids in the desert southwest USA.

This study evaluated bioaerosol emissions during land application of Class B biosolids in and around Tucson, Arizona, to aid in developing models of the fate and transport of bioaerosols generated from the land application of biosolids. Samples were collected for 20 min at distances between 2 m and 20 m downwind of point sources, using an SKC BioSampler impinger. A total of six samples were collected per sampling event, which consisted of a biosolid spray applicator applying liquid biosolids to a cotton field. Each application represented one exposure. Samples were collected in deionised water amended with peptone and antifoam agent. Ambient weather conditions were also monitored every 10 min following initiation of sampling. Concurrently with downwind samples, background (ambient) air samples were collected to compensate for any ambient airborne microorganisms. In addition, biosolids samples were collected for analysis of target indicator and pathogenic organisms. Soil samples were also collected and analysed. Significant numbers of heterotrophic plate count (HPC) bacteria were found in air samples collected during the biosolid application process. These could have arisen from soil particles being aerosolised during the land application process. Aerosolised soil may contribute significantly to the amount of aerosolised microorganisms. Soil particles may be able to more readily aerosolise, due to their low density, small particle size and low mass. Aerosolised HPC bacteria found during biosolids land application were similar to those found during normal tractor operation on non-biosolids applied fields. Coliforms and coliphages were not routinely detected even though they were found to be present in the biosolids at relatively high concentrations, 10(6) and 10(4)/g (dry weight) of biosolids respectively. This could be due to the die-off rate of aerosolised Gram-negative bacteria or sorption to the solid portion of the biosolids. Low numbers of aerosolised coliphages may likewise be due to sorption phenomena. We theorise that only organisms in the aqueous phase of the biosolids were available to desorb and be aerosolised. Animal viruses, which were not detected in the biosolids, were likewise not detected in the aerosol samples. Clostridium perfringens was detected in only a small percent of aerosol samples although it was detected during all weather conditions; other microorganisms were detected during more favourable environmental conditions (relative humidity >10%). Despite the fact that many of these organisms were present in the biosolids at significant concentrations, their presence in bioaerosols generated during the land application of biosolids was limited to only a small percentage of samples. Bacteria as well as viruses may sorb to biosolids, which contain a high percentage of organic matter, and desorption during land application of biosolids may not readily take place; therefore, these microorganisms may not be readily aerosolised.

Adsorption↗

Evaluation of electrochemically generated ozone for the disinfection of water and wastewater.

Effective wastewater treatment is critical to public health and well-being. This is especially true in developing countries, where disinfection of wastewater is frequently inadequate. People who live in these areas may benefit from wastewater disinfection using ozone. This study evaluated the ability of a new electrochemical process of ozone generation, which produced ozone continuously at high pressure and concentration by the electrolysis of water, to disinfect tap water and secondarily treated wastewater. Inactivation of Klebsiella terrigena, Escherichia coli, MS2 bacteriophage and poliovirus 1 was evaluated first in reverse osmosis (RO) treated water. Inactivation of K. terrigena (6-log), E. coli (6-log), MS2 (6-log) and poliovirus 1 (>3-log) was observed after 1 min of ozonation in a 1 L batch reactor. Experiments were then performed to assess the microbiological impact of disinfection using ozone on secondarily treated municipal wastewater. The effect of ozonation on wastewater was determined for total and faecal coliforms, bacteriophages and heterotrophic plate count (HPC) bacteria. Electrochemical ozone generators provided an effective, rapid and low-cost method of wastewater disinfection. Based on the results of this research, electrochemically generated ozone would be well suited to remote, small-scale, disinfection operations and may provide a feasible means of wastewater disinfection in developing countries.

Developing Countries↗

Giardia and Cryptosporidium removal from waste-water by a duckweed (Lemna gibba L.) covered pond.

AIMS: To determine the ability of duckweed ponds used to treat domestic waste-water to remove Giardia and Cryptosporidium. METHODS AND RESULTS: The influent and effluent of a pond covered with duckweed with a 6 day retention time was tested for Giardia cysts, Cryptosporidium oocysts, faecal coliforms and coliphage. Giardia cysts and Cryptosporidium oocysts were reduced by 98 and 89%, respectively, total coliforms by 61%, faecal coliforms by 62% and coliphage by 40%. There was a significant correlation between the removal of Giardia cysts and Cryptospordium oocysts by the pond (P < 0.001). Influent turbidity and parasite removal were also significantly correlated (Cryptosporidium and turbidity, P=0.05; Giardia and turbidity, P=0.01). CONCLUSIONS: The larger organisms (parasites) probably settled to the bottom of the pond, while removal of smaller bacteria and coliphages in the pond was not as effective. SIGNIFICANCE AND IMPACT OF THE STUDY: Duckweed ponds may play an important role in wetland systems for reduction of Giardia and Cryptosporidium.

Animals↗

Rapid reduction of Staphylococcus aureus populations on stainless steel surfaces by zeolite ceramic coatings containing silver and zinc ions.

This study demonstrates the anti-Staphylococcus aureus properties of stainless steel surfaces coated with zeolite containing 2.5% silver and 14% zinc ions. Stainless steel panels with and without the heavy-metal-containing coatings were inoculated with S. aureus and incubated at room temperature. Survival of S. aureus was significantly reduced by the silver/zinc coatings within 1 h. Many hospital surfaces could be constructed of stainless steel with silver/zinc zeolite coatings. Such measures may reduce rates of hospital-acquired S. aureus infection.

Anti-Bacterial Agents↗

Quantitative assessment of risk reduction from hand washing with antibacterial soaps.

The Centers for Disease Control and Prevention have estimated that there are 3,713,000 cases of infectious disease associated with day care facilities each year. The objective of this study was to examine the risk reduction achieved from using different soap formulations after diaper changing using a microbial quantitative risk assessment approach. To achieve this, a probability of infection model and an exposure assessment based on micro-organism transfer were used to evaluate the efficacy of different soap formulations in reducing the probability of disease following hand contact with an enteric pathogen. Based on this model, it was determined that the probability of infection ranged from 24/100 to 91/100 for those changing diapers of babies with symptomatic shigellosis who used a control product (soap without an antibacterial ingredient), 22/100 to 91/100 for those who used an antibacterial soap (chlorohexadine 4%), and 15/100 to 90/100 for those who used a triclosan (1.5%) antibacterial soap. Those with asymptomatic shigellosis who used a non-antibacterial control soap had a risk between 49/100,000 and 53/100, those who used the 4% chlorohexadine-containing soap had a risk between 43/100,000 and 51/100, and for those who used a 1.5% triclosan soap had a risk between 21/100,000 and 43/100. The adequate washing of hands after diapering reduces risk and can be further reduced by a factor of 20% by the use of an antibacterial soap. Quantitative risk assessment is a valuable tool in the evaluation of household sanitizing agents and low risk outcomes.

Adult↗

A risk assessment of emerging pathogens of concern in the land application of biosolids.

Since the development of the United States Environmental Protection Agency's 503 biosolids Rule, which includes treatment requirements to reduce the threat of pathogen transmission, many new pathogens have been recognized which could be transmitted by biosolids. A risk analysis was performed assess which emerging pathogens would be most likely to survive treatments required for Class B biosolids before land application. The literature was reviewed on the resistance of emerging pathogens to temperature and other environmental factors to assess their probability of surviving various biosolids treatment processes. In addition existing information on occurrence in biosolids and dose response models for each pathogen was reviewed. It was concluded that adenoviruses and hepatitis A virus are the most thermally resistant viruses and can survive for prolonged periods in the environment. The protozoan parasites microsporidia and Cyclospora were unlikely to survive the temperatures achieved in anaerobic digestion and do not survive well under low moisture conditions. A risk model was used to assess the risk of infection and illness from enteric viruses after application of class B biosolids.

Adenoviridae↗

Quantitative assessment of risk reduction from hand washing with antibacterial soaps.

The Centers for Disease Control and Prevention have estimated that there are 3,713,000 cases of infectious disease associated with day care facilities each year. The objective of this study was to examine the risk reduction achieved from using different soap formulations after diaper changing using a microbial quantitative risk assessment approach. To achieve this, a probability of infection model and an exposure assessment based on micro-organism transfer were used to evaluate the efficacy of different soap formulations in reducing the probability of disease following hand contact with an enteric pathogen. Based on this model, it was determined that the probability of infection ranged from 24/100 to 91/100 for those changing diapers of babies with symptomatic shigellosis who used a control product (soap without an antibacterial ingredient), 22/100 to 91/100 for those who used an antibacterial soap (chlorohexadine 4%), and 15/100 to 90/100 for those who used a triclosan (1.5%) antibacterial soap. Those with asymptomatic shigellosis who used a non-antibacterial control soap had a risk between 49/100,000 and 53/100, those who used the 4% chlorohexadine-containing soap had a risk between 43/100,000 and 51/100, and for those who used a 1.5% triclosan soap had a risk between 21/100,000 and 43/100. The adequate washing of hands after diapering reduces risk and can be further reduced by a factor of 20% by the use of an antibacterial soap. Quantitative risk assessment is a valuable tool in the evaluation of household sanitizing agents and low risk outcomes.

Anti-Infective Agents↗

Fate of indicator microorganisms, Giardia and Cryptosporidium in subsurface flow constructed wetlands.

Limited information is available on the ability of subsurface flow wetlands to remove enteric pathogens. Two multi-species wetlands, one receiving secondary sewage effluent and the other potable (disinfected) groundwater were studied from February 1995 to August 1996, at the Pima County Constructed Ecosystems Research Facility in Tucson, Arizona. Each wetland had a retention time of approximately 4 days. The objectives of this study were (1) to evaluate the ability of multi-species subsurface wetlands to physically remove Giardia cysts; Cryptosporidium oocysts, total and fecal coliforms, and coliphages; and (2) to determine the likely impact of local wildlife on the occurrence of these indicators and pathogens. In the wetland receiving secondary sewage effluent, total coliforms were reduced by an average of 98.8% and fecal coliforms by 98.2%. Coliphage were reduced by an average of 95.2%. Both Giardia cysts and Cryptosporidium oocysts were reduced by an average of 87.8 and 64.2%, respectively. In the wetland receiving disinfected groundwater, an average of 1.3 x 10(2) total coliforms/100 mL and 22.3 fecal coliforms/100 mL were most likely contributed by both flora and fauna. No parasites or coliphages were detected.

Animals↗

Chemical and microbial characterization of household graywater.

In arid areas, the search for efficient methods to conserve water is of paramount importance. One of the methods of water conservation available today is graywater recycling--the reuse of water from the sinks, showers, washing machine, and dishwasher in a home. The purpose of this project was to characterize the chemical and microbial quality of graywater from a single-family home with two adults. Water samples from a graywater holding tank were analyzed over a seven-month period for total coliforms, fecal coliforms, fecal streptococci, Staphylococcus aureus (S. aureus), Pseudomonas aeruginosa (P. aeruginosa), and coliphages. The pH, turbidity, biological oxygen demand (BOD), suspended solids (SS), electrical conductivity (EC), sulfates (SO4), and chlorides (Cl) were also measured. The mean numbers of total coliforms, fecal coliforms, fecal streptococci, and P. aeruginosa were 8.03 x 10(7), 5.63 x 10(5), 2.38 x 10(2), and 1.99 x 10(4) CFU/100 mL, respectively. S. aureus and coliphages were not detected. In the chemical analysis, mean values of 7.47 for pH, 43 nephelometric turbidity units (NTU) for turbidity, 64.85 mg/L for BOD, 35.09 mg/L for SS, 0.43 mS/cm for EC, 59.59 mg/L for SO4, and 20.54 mg/L for Cl were measured. These data were compared to data taken in 1986 and 1987, when two adults and one child lived in the household. Analysis showed no statistically significant difference in levels of total coliforms and suspended solids between the two data sets. There were statistically significant differences in levels of fecal coliforms, pH, turbidity, chlorides, sulfates, and BOD between the two households. Fecal coliforms, turbidity, and BOD were higher in the household with two adults and one child. Levels of Cl, SO4, and pH were higher in the household with two adults.

Adult↗

Removal of pathogenic and indicator microorganisms by a constructed wetland receiving untreated domestic wastewater.

Wetlands containing floating, emergent and submergent aquatic plants, and other water-tolerant species have been found to economically provide a mechanism of enhancing the quality of domestic wastewater. The use of constructed wetlands for the removal of indicator bacteria (total and fecal coliforms), coliphages, protozoan parasites (Giardia and Cryptosporidium) and enteric viruses was investigated. A pilot scale constructed wetland consisting of two cells, one planted with bulrush and the other unplanted bare sand, were used to compare their efficiency in removing pathogens from raw sewage. Overall more than 90 percent of all microorganisms studied were removed by either of the two systems with a 1 to 2 day retention time. Removal of all mentioned microorganisms was greater from the surface flow in the unplanted cell than in the planted cell, except for Giardia and Cryptosporidium, although the differences were not statistically significant. Enteric viruses, coliphages and indicator bacteria were found to penetrate 2 m below the surface, although concentrations were reduced by greater than 99 percent in both cells. Less virus penetration into the sand occurred in the planted wetland versus the unplanted wetland. Water temperature was found to be the most important factor in the removal of enteric bacteria and viruses, while turbidity reduction was related to Giardia removal. These results demonstrate that significant reductions of pathogenic microorganisms can occur in constructed wetlands receiving untreated domestic wastewater with only a 1-2 day retention time.

Animals↗

ICC/PCR detection of enteroviruses and hepatitis A virus in environmental samples.

This study applied the integrated cell culture/polymerase chain reaction methodology (ICC/PCR) for rapid and specific detection of both cytopathogenic and noncytopathogenic viruses. Results of this study showed that the use of direct RT-PCR or conventional cell culture alone may yield erroneous results with the analysis of environmental samples. The purpose of this study was to compare cultural, molecular, and combined assays for the most effective method of virus detection in variable environmental samples. Using ICC/PCR, stock enterovirus inocula of > or =10 PFU were PCR positive in at least 4/5 replicate flasks after only 5 h of incubation in cell culture, and in all flasks after > or =10 h. An inoculum of one PFU was detected by PCR after 20 h of cell culture incubation while for concentrations of virus below one PFU, 25 h of incubation was sufficient. Similarly, hepatitis A virus (HAV) inocula of 100 MPN/flask, produced indeterminate CPE in cell culture, but were clearly detected by ICC/PCR following 48 h of incubation. Lower levels of HAV, 1 and 10 MPN, were detected by ICC/PCR after 96 to 72 h of incubation, respectively. Cell culture lysates from 11 environmental sample concentrates of sewage, marine water, and surface drinking water sources, were positive for enteroviruses by ICC/PCR compared to 3 positive by direct RT-PCR alone. Results from ICC/PCR eventually agreed with cell culture but required < or =48 h of incubation, compared to as long as 3 weeks for CPE following incubation with BGM and FRhK cells.

Cell Culture Techniques↗

Removal of bacterial indicators and pathogens from dairy wastewater by a multi-component treatment system.

Microbial removal by a multi-component treatment system for dairy and municipal wastewater is being studied in Arizona, USA. The system consists of paired solids separators, anaerobic lagoons, aerobic ponds and constructed wetlands cells. The organisms under study include: total coliform, fecal coliform, enterovirus, Listeria monocytogenes, Clostridium perfringens, coliphage, Giardia lamblia and Cryptosporidium parvum. Organism removal rates from dairy wastewater varied from 13.2 per cent for fecal coliform to 94.9 per cent for coliphage. It appears that the much higher turbidity of the dairy wastewater, nearly 1,300 NTU, decreased the treatment systems' ability to remove some microbial indicators and pathogens. Information from this study can be used to determine the adequacy of multi-component treatment systems for the control of wastewater-borne pathogens, both in municipal treatment systems as well as in confined animal feeding operations (CAFO). This information also can assist municipalities and the CAFO industry in the implementation of rational and efficient treatment strategies for appropriate reuse of wastewaters.

Agriculture↗