PubMed Health⌕ Search

Biomedical subjects

C P Gerba

Publications and source records attributed to C P Gerba.

At least 91 records · Page 5Linked to original sources

Concentration of coliphage from water and sewage with charge-modified filter aid.

Methods of detecting and concentrating animal viruses from large volumes of water and wastewater have experienced rapid development in recent years, but only a few methods are available for the concentration of bacteriophages. The present study describes the use of a charge-modified (Zeta Plus) filter aid (AMF Cuno, Meriden, Conn.) for the concentration of coliphages from large volumes of water and sewage. Coliphages MS-2 and f2 were efficiently adsorbed from water and sewage to the positively charged filter aid. Elution was accomplished with 4% beef extract--0.5 M NaCl adjusted to pH 9.5. The recovery of f2 from 10- to 20-liter volumes of tap water ranged between 11 and 70%, and the recovery of MS-2 ranged between 43 and 70%. The efficiency of recovery of naturally occurring coliphages from secondarily treated sewage ranged between 16 and 44%. This technique appears to be promising because it requires low-cost equipment (47-mm polypropylene filter housing), is easy to handle, and can filter large volumes of water (greater than or equal to 20 liters) with good recoveries. Filtrations can be conducted at the ambient pH of the water, and the unit cost per filtration (i.e., the cost of filter aid) comes to less than three cents per sampling. The technique could be useful in evaluation of viral water quality, study of ecology and occurrence of phages in natural waters, and isolation of rare phages from natural waters.

Coliphages↗

Development of a method for detection of human rotavirus in water and sewage.

The simian rotavirus SA11 was used to develop a simple, reliable, and efficient method to concentrate rotavirus from tap water, treated sewage, and raw sewage by absorption to and elution from Filterite fiberglass-epoxy filters. SA11 adsorbed optimally to Filterite filters from water containing 0.5 mM AlCl3 at pH 3.5. Filter-bound virus was eluted with 0.05 M glycine-NaOH supplemented with 10% tryptose phosphate broth at pH 10. SA11 was quantitated by plaque assay, whereas human rotavirus was detected by immunofluorescence. The method was applied to detect rotavirus in raw and treated sewage at two Houston, Tex., sewage treatment plants. The sewage isolates were identified as rotavirus, probably a human strain, based on several criteria. The sewage isolates were detectable by an immunofluorescence test, using anti-SA11 serum which would detect the simian, human bovine, and porcine rotaviruses. No reaction was noted by immunofluorescence with the reoviruses or several common enteroviruses. The sewage isolates were neutralized by convalescent sera from a human adult and infant who had been infected by rotavirus as well as by a hyperimmune serum prepared in guinea pigs against purified human rotavirus. Preimmune or preillness sera did not react with the isolates by neutralization or immunofluorescence. The natural isolates were sensitive to pH 11 and other inactivating agents, similar to SA11. The buoyant density of the sewage isolates in CsCl gradients was 1.36 g/cm3, which is the value usually reported for complete, infectious rotavirus particles. The double-shelled particle diameter was 67.1 +/- 2.4 nm. Finally, electron micrographs of cell lysates inoculated with the sewage isolate showed particles displaying characteristic rotavirus morphology.

Absorption↗

Uptake and survival of enteric viruses in the blue crab, Callinectes sapidus.

Uptake of poliovirus 1 by the blue crab, Callinectes sapidus, was measured to assess the likelihood of contamination by human enteric viruses. Virus was found in all parts of the crab within 2 h after the crab was placed in contaminated artificial seawater. The highest concentrations of virus were found in the hemolymph and digestive tract, but the meat also contained virus. The concentration of virus in the crabs was generally less than in the surrounding water. Changes in salinity did not substantially affect the rate of accumulation. An increase in temperature from 15 to 25 degrees C increased the rates of both uptake and removal. Poliovirus survived up to 6 days in crabs at a temperature of 15 degrees C and a salinity of 10 g/kg. When contaminated crabs were boiled, 99.9% of poliovirus 1, simian rotavirus SA11, and a natural isolate of echovirus 1 were inactivated within 8 min. These data demonstrate that viruses in crabs should not pose a serious health hazard if recommended cooking procedures are used.

Animals↗

Effect of soil permeability on virus removal through soil columns.

Laboratory experiments were performed on four different soils, using 100 cm long columns, to determine the extent of virus movement when wastewater percolated through the soils at various hydraulic flow rates. Unchlorinated secondary sewage effluent seeded with either poliovirus type 1 (strain LSc) or echovirus type 1 (isolate V239) was continuously applied to soil columns for 3 to 4 days at constant flow rates. Water samples were extracted daily from ceramic samplers at various depths of the column for the virus assay. The effectiveness of virus removal from wastewater varied greatly among the different soil types but appeared to be largely related to hydraulic flow rates. At a flow rate of 33 cm/day, Anthony sandy loam removed 99% of seeded poliovirus within the first 7 cm of the column. At flow rates of 300 cm/day and above, Rubicon sand gave the poorest removal of viruses; less than 90% of the seeded viruses were removed by passage of effluent through the entire length of the soil column. By linear regression analyses, the rate of virus removal in soil columns was found to be negatively correlated with the flow of the percolating sewage effluent. There was no significant difference in rate of removal between poliovirus and echovirus in soil columns 87 cm long. The rate of virus removal in the upper 17 cm of the soil column was found to be significantly greater than in the lower depths of the soil column. This study suggests that the flow rate of water through the soil may be the most important factor in predicting the potential of virus movement into the groundwater. Furthermore, the length of the soil column is critical in obtaining useful data to predict virus movement into groundwater.

Enterovirus B, Human↗

Occurrence of enteroviruses in community swimming pools.

Municipal swimming pools and wading pools were examined for the presence of human enteric viruses using a portable virus concentrator at the site to concentrate viruses from 100-gallon to 500-gallon samples. Ten of 14 samples contained viruses; three of these were positive for virus in the presence of residual free chlorine. Enteroviruses were isolated from two pools which exceeded the 0.4 ppm free residual chlorine standard. This study appears to be supportive of recent evidence that indicates a higher incidence of enterovirus infection among bathers. All seven wading pool samples contained virus. Coxsackieviruses B3 and B4, poliovirus 1, and echovirus 7 were isolated. Total coliform bacteria were not adequate indicators of the presence of virus, as six of the samples were positive for virus but negative for coliforms. Total plate counts appeared to provide a better indication of the sanitary quality of the pool water, but viruses could still be detected in samples that met currently recommended bacterial levels. It is possible that swimming and wading pools may serve as a means of transmission of enteroviral disease, especially in children, during summer months.

Enterovirus↗

Concentration of bacteriophage lysates by filter chromatography.

High-titered phage stocks are required for carrying out genetic and physicochemical studies on bacteriophages. This study describes a simple method for the concentration of coliphages MS-2 and T2 by charge-modified filters. Phage lysates were first clarified by filtration through serum-coated membrane filters. The clarified lysate was adjusted to pH 6 and passed through a Zeta-plus filter (30 S size). Greater than 99% virus adsorption occurred under these conditions. Adsorbed viruses were successfully eluted by small volumes of 3% beef extract (pH 10) which was subsequently neutralized with 3% beef extract (pH2). A concentration factor as great as 126 could be achieved by this method, with recoveries ranging from 54% to 97% (average = 60%).

Adsorption↗

Stability of simian rotavirus in fresh and estuarine water.

The rates of inactivation of poliovirus 1, echovirus 7, coxsackievirus B3, and simian rotavirus SA11 were compared in polluted and nonpolluted fresh and estaurine water samples. The study was done in two parts, comparing virus survival in samples taken 1 year apart from the same sites. The survival studies were performed at 20 degrees C and at the natural pH of the water samples. In the first part of the study, the time required for a 3-log10 reduction in the initial virus titers was 2 to 3 days in the estaurine water samples and varied from 3 to greater than 14 days in the freshwater samples. In the second part of the study, no clear distinction was found between survival of viruses in freshwater samples and survival in estaurine water samples. The time required for a 3-log10 reduction in the initial virus titers in the second part of the study varied from 12 to greater than 14 days. This indicates that there is a nonseasonal change in factors in the water which affect virus survival. In this study SA11 survival time (used as a model for human virus) was well within the range exhibited by the enteroviruses, indicating that it also is environmentally stable in natural waters.

Enterovirus B, Human↗

Concentration of coliphages from large volumes of water and wastewater.

Membrane filter adsorption-elution technology has been extensively used for the concentration and detection of animal viruses from large volumes of water. This study describes the development of positively charged microporous filters (Zeta Plus) for the concentration of coliphages from large volumes of water and wastewater. Four different coliphages were studied: MS-2, phi X174, T2, and T4. Positively charged microporous filters were found to efficiently adsorb these coliphages from tap water, sewage, and lake water at neutral pH. Adsorbed viruses were eluted with a 1:1 mixture of 8% beef extract and 1 M sodium chloride at pH 9. Using this method, coliphages could be concentrated from 17-liter volumes of tap water with recoveries ranging from 34 to 100%. Coliphages occurring naturally in raw and secondarily treated sewage were recovered with average efficiencies of 56.5 and 55.0%, respectively. This method should be useful in isolation of rare phages, the ecology of phages in natural waters, and the evaluation of water quality.

Coliphages↗

Simple method for the concentration of influenza virus from allantoic fluid on microporous filters.

Membrane filter adsorption-elution is an efficient method for concentration and partial purification of several types of viruses from various aqueous solutions. For efficient virus adsorption to negatively charged filters, the sample is adjusted to pH 3.5 and trivalent salts are added before filtration. Since influenza virus is sensitive to extremes in pH, it cannot be concentrated by ordinary filters. Zeta Plus filters, which have a net positive charge of up to 5 or 6, were evaluated for the concentration of influenza virus from infectious allantoic fluids. Influenza virus efficiently adsorbed to Zeta Plus filters at pH 6, and addition of salts was not necessary. Adsorbed virus was eluted in a small volume of 2% bovine serum albumin plus 1 M NaCl at pH 10. By this procedure, viruses in 100 ml of allantoic fluid were concentrated to a final volume of 8 ml, with an average recovery efficiency of 71.0%.

Adsorption↗

Movement of endotoxin through soil columns.

Land treatment of wastewater is an attractive alternative to conventional sewage treatment systems and is gaining widespread acceptance. Although land application systems prevent surface water pollution and augment the available water supplies, the potential dangers to human health should be evaluated. Since sewage may contain high amounts of bacterial endotoxin, the removal of endotoxin from sewage by percolation through soil was investigated. It was found that 90 to 99% of the endotoxin was removed after travel of sewage through 100 to 250 cm of loamy sand soil. When distilled water was allowed to infiltrate into the soil to simulate rainfall, the endotoxin was mobilized and moved in a concentrated band through the soil column. On testing samples from actual land treatment sites, as much as 480 ng of endotoxin per milliliter was found in some groundwater samples. The presence of endotoxin in potable water is known to be a potential problem under some circumstances, but the importance of endotoxin in water supplies has not been fully assessed. Therefore, the design, operation, and management of land application systems should take into account the fate of endotoxin in groundwater beneath the sites.

Endotoxins↗

Relationships between environmental factors, bacterial indicators, and the occurrence of enteric viruses in estuarine sediments.

Current standards for evaluation of the public health safety of recreational and shellfish-harvesting waters are based upon bacteriological analysis, but do not include an evaluation of the number of viruses. The objective of this study was to determine the occurrence of enteric viruses in estuarine sediments and to find a relationship, if any, between the presence of viruses in seawater or sediment or both and various biological and physicochemical characteristics of the environment. Viruses were found in greater numbers in sediment than in overlying seawater on a volume basis. Several types of enteroviruses were isolated: coxsackievirus types A16, B1, and B5, echovirus type 1, and poliovirus type 2. On several occasions, viruses were isolated from sediments when overlying seawaters met bacteriological water quality standards for recreational use. Statistical analysis of the relationship between viruses in seawater or in sediment and other variables measured yielded only one significant association: the number of viruses in sediment was found to be positively correlated with the number of fecal coliforms in sediment. No other physical, chemical, or biological characteristic of seawater or sediment that was measured showed statistically significant association with viral numbers. No correlation was found between bacterial indicators and virus in the overlying waters. The data indicated that evaluation of the presence of bacteria and viruses in sediment may provide additional insight into long-term water quality conditions and that indicator bacteria in water are not reflective of the concentration of enteric viruses in marine waters.

Clostridium↗

Evaluation of various soil water samplers for virological sampling.

Two commercially available soil water samplers and a ceramic sampler constructed in our laboratories were evaluated for their ability to recover viruses from both tap water and secondary sewage effluent. The ceramic sampler consistently gave the best recoveries of viruses from water samples. Soil columns containing ceramic samplers at various depths provide a simple method for studying virus transport through sewage-contaminated soils.

Enterovirus B, Human↗

Influence of estuarine sediment on virus survival under field conditions.

The survival of poliovirus 1 (LSc) and echovirus 1 (Farouk) in estuarine water and sediment was studied in Galveston Bay, Texas. Viruses were suspended in estuarine water and sediment both in dialysis tubing and in chambers constructed with polycarbonate membrane walls. Virus inactivation rates in seawater were similar in both types of chambers. Virus adsorption to sediment greatly increased survival time. The time required to inactivate 99% (T-99) of poliovirus increased from 1.4 days in seawater alone to 6.0 days for virus adsorbed to sediment at a relatively nonpolluted site. At a more polluted site, poliovirus T-99 was increased from approximately 1 h to 4925 days by virus adsorption to sediment. This study demonstrates that under field conditions virus association with estuarine sediment acts to prolong its survival in the marine environment.

Enterovirus B, Human↗

Survival of enteroviruses in rapid-infiltration basins during the land application of wastewater.

The downward migration through soil of seeded poliovirus type 1 and echovirus type 1 and of naturally occurring enteroviruses during infiltration of sewage effluent through rapid-infiltration basins was investigated. After 5 days of flooding, the amount of seeded poliovirus type 1 that had migrated 5 to 10 cm downward through the soil profile was found to be 11% of that remaining at the initial burial depth. The amount of echovirus type 1 determined to have moved an equal distance was at least 100-fold less. Migration of naturally occurring enteroviruses during infiltration of sewage effluent through soil could not be measured with accuracy because of the possibility of virus survival from previous applications of effluent. The rate of inactivation for seeded poliovirus 1 and echovirus 1 buried in the infiltration basins ranged between 0.04 and 0.15 log10 units per day during the time when the basins were flooded. Inactivation of these same seeded virus types and of indigenous enterovirus populations in the infiltration basins during the drying portion of the sewage application cycle ranged between 0.11 and 0.52 log10 units per day. The rate of virus inactivation was dependent upon the rate of soil moisture loss. These results indicate that drying cycles during the land application of wastewater enhance virus inactivation in the soil.

Enterovirus↗

Thermostabilization of enteroviruses by estuarine sediment.

The effect of estuarine sediment on the thermoinactivation of poliovirus type 1 and echovirus type 1 was evaluated. Poliovirus survival was prolonged at 24 and 37 degrees C but not at 4 degrees C in the presence of sediment over the time periods observed. Further inactivation studies were performed at 50 and 55 degrees C to maximize the thermal effects, and similar protection was observed. The supernatant fluid from a mixture of seawater and sediment lacked the protective effect against thermoinactivation, suggesting that prolonged virus survival in the presence of sediment was due to adsorption to particulates. From these observations, it appears that the adsorption of enteroviruses to estuarine sediments may play a significant role in protecting them against thermoinactivation.

Adsorption↗

Capture of latex beads, bacteria, endotoxin, and viruses by charge-modified filters.

This report demonstrates how electropositive filters can be used to enhance the removal of microorganisms and other negatively charged particles from water. It was shown that electropositive depth filters were capable of adsorbing viruses and endotoxins many times smaller than the average pore size of the filter. Electronegative filters of similar porosity or electropositive filters that had been treated to destroy the positive charge were almost ineffective under similar conditions for the removal of viruses and small latex spheres. The results of this study indicate that electropositive filters are highly effective in the removal of a wide range of contaminants over a wide range of pH values and ionic conditions.

Endotoxins↗

Simple method for concentration of bacteria from large volumes of tap water.

Membrane adsorption-elution techniques have made it possible to concentrate and detect small numbers of viruses in large volumes of water and wastewater, but no such methods are available for quantitative recovery of bacteria. A number of waterborne disease outbreaks of "unknown etiology" in the United States are suspected to have been caused by pathogens present in numbers too small to be detected by currently available methodology. The present study reports on the use of positively charged depth filters for the concentration and detection of bacteria in large volumes of tap water. In this method, dechlorinated tap water was passed, under positive pressure, through positively charged filter media (Zetaplus, 05S). More than 90% of seeded bacteria adsorbed to these filters at ambient pH levels. Adsorbed bacteria were eluted by passing a small volume of Trypticase soy broth in the direction opposite of the influent flow. By this method, Escherichia coli and Salmonella serovar B organisms in 20 liters of tap water were concentrated in a final volume of 50 ml, with an average recovery efficiency of greater than or equal to 30%.

Adsorption↗