[Electrophysiological bases of atrial fibrillation].
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to C Pappone.
Explore the source record for details and available documents.
Arrhythmogenic right ventricular dysplasia (ARVD) is a predisposing factor for sport-related cardiac arrest (CA), sudden cardiac death (SD), and life-threatening ventricular tachyarrhythmias (VT). The aim of this study was the assessment of athletes with ARVD, particularly the CA survivors. From 1974 to January 1996, 1642 competitive athletes (aver. 25.5 yr.), 136 of whom were top level athletes (TLA), were studied for important arrhythmic manifestations. All athletes underwent an individualised study protocol including a series of non invasive and invasive diagnostic techniques. One hundred and one athletes (90 males, 11 females, aver. 25.9 yr.) were diagnosed as being affected by ARVD on the basis of the WHO/ISFC criteria. The same percentage (about 6%) of ARVD is present in both the general arrhythmic athletes population and in the subgroup of TLA. Prevalence of ARVD among athletes with CA or SD is high (respectively 23% and 25%), confirming the observation that ARVD is one of the major causes of SD in Italian athletes. All CA were athletic activity related, indicating the potentiality of exercise as a cause of electrical destabilisation in subjects with ARVD. In athletes with documented ARVD intense sport activity has to be proscribed. In athletes at risk of CA or SD an aggressive treatment, ICD implantation and RF catheter ablation must be taken into consideration.
INTRODUCTION: Atrial fibrillation (AF) is a rare event in people younger than 25 years of age, but is probably more frequent in competitive athletes. We analyzed the presence of AF, paroxysmal or chronic, in a population of young elite athletes, including previous Olympic and World champions, who were studied for arrhythmias that endangered their athletic careers. METHODS AND RESULTS: From 1974 to June 1977, 1,772 athletes identified with arrhythmias (1,464 males and 308 females; mean age 21 years) underwent individualized work-ups. Among these, 146 (122 males and 24 females; mean age 24 years) were young elite athletes. They were studied from 1985 to 1997, with a mean follow-up of 62 months. Of the 146 young elite athletes, 13 (9%) had AF (paroxysmal in 11 and chronic in 2); all were male. The paroxysmal AF occurred during effort (n = 7), after effort (n = 1), or at rest (n = 3) and was reinduced by transesophageal pacing or endocavitary electrophysiologic testing under the same clinical circumstances. AF was the cause of symptoms in 13 (40%) of 22 young elite athletes with long-lasting palpitations. Five young elite athletes had a substrate for AF: Wolff-Parkinson-White syndrome (WPW) in 3, arrhythmogenic right ventricular dysplasia (ARVD) in 1, healed myocarditis in 1, and was considered idiopathic in 8. All elite athletes are alive with a mean follow-up of 62 months and 7 continue in their sports: 3 after radiofrequency catheter ablation (of WPW in 2 and AF with maze-type nonfluoroscopic approach in 1) and 4 after a period of de-training. CONCLUSIONS: AF, occurring in young elite athletes and affecting only males, is one of the most frequent causes of prolonged palpitations and is reproduced easily by transesophageal atrial pacing or electrophysiologic testing. AF may be a cause of disqualification from sports eligibility, but may disappear if the athletic activity is stopped for an adequate period of time, if trigger mechanisms are corrected (i.e., WPW), or if the substrate is modified.
Explore the source record for details and available documents.
INTRODUCTION: Inappropriate sinus tachycardia (IST) has been observed following radiofrequency ablation (RFA) of the AV nodal fast pathway. This study was aimed to prospectively analyze the incidence and clinical significance of IST following RFA of para-Hisian accessory pathways (APs). METHODS AND RESULTS: Twenty-eight patients (pts) with para-Hisian APs underwent RFA. An AP was defined as para-Hisian whenever its atrial and ventricular insertions were associated with a His-bundle potential > or = 0.1 mV. RF current was always delivered at the atrial aspect of the tricuspid annulus, to a site where the His-bundle potential was < 0.15 mV. Time- and frequency-domain analysis of heart rate variability was performed in 22 patients, before and after RFA. Abolition of AP conduction was obtained in all pts, and no AV conduction alteration occurred. Six pts (21.4%) presented with IST 45 to 240 minutes after the ablation procedure. In 5 of them, IST disappeared spontaneously within 72 hours, whereas in 1 pt beta-blockers were required for 2 months. The atrial potential amplitude (1.217 +/- 0.264 mV vs 0.882 +/- 0.173 mV, P = 0.009) and A/V potential amplitude ratio (2.633 vs 1.686, P = 0.05) were significantly higher in pts who developed IST than in those who did not. A marked decrease in heart rate variability was observed only in pts who developed IST. CONCLUSION: IST is a relatively frequent complication after RFA of para-Hisian APs: it is generally short-lasting and usually does not require any treatment. IST after catheter ablation is likely to depend upon transient parasympathetic denervation of the sinus node.
Hypertrophic cardiomyopathy (HC) is characterized by impaired diastolic function and, in about 1/4 of patients, left ventricular (LV) outflow tract obstruction. Atrioventricular (AV) pacing diminishes LV outflow tract gradient in HC, but impairs diastolic function in the experimental animal and in different categories of patients. To investigate the effects of AV pacing on hemodynamics and LV function in obstructive HC, 16 patients with HC were studied by cardiac catheterization and simultaneous radionuclide angiography during atrial and AV pacing. The resting LV outflow tract gradient decreased with AV pacing from 60 +/- 34 to 38 +/- 37 mm Hg (mean +/- SD; p <0.001). Regional ejection fraction decreased significantly at the septal level from 0.81 +/- 0.21% to 0.69 +/- 0.27% (p <0.01). Pulmonary artery wedge pressure increased from 10 +/- 5 to 15 +/- 6 mm Hg (p <0.001). AV pacing induced asynchrony (i.e., the coefficient of variation of the time to end-systole increased from 7 +/- 4% to 14 +/- 10% (p <0.01). The time constant of isovolumetric relaxation (t) increased from 58 +/- 24 to 74 +/- 33 ms (p <0.02), and peak filling rate decreased from 491 +/- 221 to 416 +/- 184 ml/s (p <0.05). Thus, AV pacing greatly diminishes resting obstruction through a reduction in septal ejection fraction (i.e., an increase in LV outflow tract width in systole), but impairs active diastolic function and increases filling pressures. These latter effects are potentially detrimental in patients with HC in whom diastolic dysfunction is present.
OBJECTIVES: We compared the efficacy of two different mapping techniques in identifying the ablation site for atrial tachycardia. Moreover, we evaluated the additive positive predictive value of mechanical interruption of atrial tachycardia to reduce the number of ineffective radiofrequency applications. BACKGROUND: Radiofrequency catheter ablation has been suggested as a highly effective technique to treat drug-resistant atrial tachycardia. However, irrespective of the mapping technique utilized, success was most often achieved with a large number of radiofrequency applications. METHODS: Forty-five patients with atrial tachycardia underwent radiofrequency catheter ablation. Mapping techniques included identification of earliest atrial activation and pace-mapping concordant sequence. RESULTS: Atrial tachycardia was successfully treated in 42 (93.3%) of 45 patients with a mean of 3.9 radiofrequency pulses/patient. An interval between the onset of the intracavitary atrial deflection and the onset of the P wave during atrial tachycardia (AP interval) > or = 30 ms (p < 0.001) and pace-mapping concordant sequence (p = 0.01) were all significant predictors of outcome. An AP interval > or = 30 ms and a pace-mapping concordant sequence were highly sensitive (92.8%, 95% confidence interval [CI] 80.5% to 98.5%; 85.7%, 95% CI 71.5% to 94.6%, respectively) but less specific (47.8%, 95% CI 37.9% to 58.2%, 36.8%, 95% CI 27.6% to 47.2%, respectively) in identifying the site of ablation. By using atrial tachycardia mechanical interruption combined with the AP interval >30 ms or the pace-mapping concordant sequence, we obtained a specifically of 76.5% (95% CI 66.4% to 84.0%) and 73.5% (95% CI 63.2% to 81.4%), respectively, and a positive predictive value of 49.2% and 44.6%, respectively. CONCLUSIONS: An AP interval > or = 30 ms and a pace-mapping concordant sequence were reliable mapping features for predicting the outcome of the ablation procedure. Mechanical interruption of atrial tachycardia improved the specificity and positive predictive value of these two mapping techniques.
BACKGROUND: Recently radiofrequency (RF) catheter ablation (CA) of atrial tachycardia (AT) showed to be highly effective with a low incidence of compliance. Aim of our study was to report the results and follow-up of RFCA of drug-refractory AT in 59 consecutive patients (pts). METHODS: Two mapping techniques were used to localize the ablation site of AT: the earliest atrial activation and the pace-mapping. Traumatic interruption of AT was used to verify the ablation site identified by the previous procedures. Moreover we evaluated the sensitivity, specificity and the positive predictive value of the three mapping techniques. RESULTS: AT was successfully treated in 55/59 (93.2%) pts with a mean of 4.0 +/- 3.8 (range 1-16) RF pulses for patient. The mean procedure time was 185.2 +/- 48.5 min with a mean rx-time of 41.5 +/- 21.3 min. An interval between the onset of the intracavitary atrial deflection and the onset of the P-wave, during atrial tachycardia, (AP interval) > or = 30 ms and pace-mapping concordant sequence were highly sensitive (90.9% and 89.1%) but less specific (49.2% and 33.9%) in identifying the site of ablation. By using atrial tachycardia traumatic interruption combined with the AP interval > 30 ms or the pace-mapping concordant sequence we obtained a specificity of 78.7% and 77.0% respectively and a positive predictive value of 48.0% and 46.8% respectively. Four recurrences (7.3%) were observed during a mean follow-up of 23.4 +/- 13.3 months. In the 22 (37.3%) pts with dilated cardiomyopathy, chest Xr and echocardiography showed a significant decrease of cardiothoracic index (0.56 +/- 0.08 pre ablation, 0.43 +/- 0.07 post ablation, p < 0.001) and end-diastolic diameter (64 +/- 8 mm pre ablation, 52 +/- 8 mm post ablation, p < 0.001) and a significant improvement of left ventricular ejection fraction (37 +/- 9% pre ablation, 48 +/- 11% post ablation, p < 0.05). CONCLUSION: The RFCA of AT was effective and safe. Moreover we observed a hemodynamic improvement in patients with reduced ejection fraction and increased cardiac volumes. An AP interval > or = 30 ms and the pace-mapping concordant sequence were reliable features to predict the outcome of the ablation procedure. Traumatic ablation of atrial tachycardia improved the specificity and the positive predictive value of these two mapping techniques and was able to predict the response to radiofrequency with a high specificity.
Explore the source record for details and available documents.
Aim of our study was to retrospectively evaluate atrioventricular conduction 24 hours after selective radiofrequency catheter ablation of the fast pathway or after selective ablation of the slow pathway of the atrioventricular nodal reentrant tachycardia circuit. Electrophysiologic modifications were retrospectively analyzed in 47/48 patients successfully submitted to fast pathway ablation and in 90/93 patients successfully submitted to slow pathway ablation. The atrioventricular conduction intervals (P-Q and A-H), both anterograde and retrograde Wenckebach point, the effective refractory period of atrioventricular node and the atrioventricular node function curve were evaluated before and after selective radiofrequency catheter ablation of slow and fast pathway. We identified the fast pathway ablation potential as: A:V ratio > or = 2:1, His electrogram < or = 150 microV. The slow pathway potential was identified as the widest, sharpest and latest atrial electrogram recorded during sinus rhythm in the posteroseptal region of the atrioventricular junction or as the widest, sharpest and earliest observed during retrograde conduction. We observed a significant increase in the P-Q and A-H intervals in patients submitted to fast pathway ablation, while no significant modification of these parameters was appreciated in patients submitted to slow pathway ablation. No significant modification of anterograde Wenckebach point (NS) was observed in patients submitted to successfully ablation of fast pathway while a statistically significant increase in anterograde Wenckebach point (p = 0.03) was observed in patients submitted to slow pathway ablation. After selective fast pathway ablation, retrograde conduction was absent in 82.9% of patients submitted to ablation; in the remaining 17.1% a significant increase of retrograde Wenckebach point was observed.(ABSTRACT TRUNCATED AT 250 WORDS)
Surgical or catheter ablation of accessory pathways by means of high energy shock has been substantial associated with morbidity and mortality. On the contrary radiofrequency current, an alternative energy source for ablation, has a low incidence of complications and a very high success rate. Aim of this study was to relate about the results using catheter ablation of accessory pathways by radiofrequency current in our Electrophysiologic laboratory. Radiofrequency current (20-40 W) was delivered between a large-tip catheter electrode positioned against the mitral or tricuspid anulus and a standard adhesive electrosurgical dispersive pad applied to the left chest wall. When possible radiofrequency delivery was guided by catheter recordings of accessory pathway activation. Ablation was attempted in 181 patients with 191 accessory pathways. We obtained successful ablation of 187/191 accessory pathways and accessory pathway conduction was eliminated in 177/181 patients. During a mean follow-up of 14 +/- 10 months preexcitation returned in 7 patients (3.9%). All underwent a second successful ablation. In 1 patient, during the procedure, we observed a transient ischemic attack, with no complications. In accordance to other reports we conclude that radiofrequency ablation is highly effective in ablating accessory pathways, with low morbidity and no mortality.
Aim of this study is to suggest our methodological approach for transcatheter ablation of Kent bundles by radiofrequency energy as to the potential ablation sites, the need in unipolar or bipolar recording mode, single catheter or multiple catheters mapping of anomalous pathways, the vascular approach for both left sited and right sited anomalous pathways, and finally the duration and power to supply. The recording of Kent potential and/or a Va-QRS interval > or = 0 ms have been considered significant predictors of success (respectively p < 0.001 and p < 0.05). The unipolar recording mode has been considered critical in the choice of ablation site in 47 (29.9%) patients. A 6-catheter approach for both diagnostic electrophysiologic studies and mapping allowed us to easily localize accessory pathways and to record either a probable or possible Kent potential in a high percentage of patients and to reduce the permanence of the ablation catheter in the left ventricle. By transaortic retrograde approach in ablating left sited anomalous pathways, we obtained a high success rate, while right sited accessory pathway were approached from the inferior vena cava. In right sited anomalous pathway we delivered radiofrequency energy for a longer time in order to avoid a relapse soon after the procedure. We performed ablation of 174/178 (97.7%) anomalous pathways in 165/169 (97.6%) patients. We observed a 3.8% relapse during a mean follow up of 13 +/- 9 months.
We review our experience with the transvenous Medtronic Pacer Cardioverter Defibrillator System (Model 7217B), a multifunction implantable pacer defibrillator combined with a transvenous lead system (Transvene). From April 1991 to October 1992, we implanted this device in 19 consecutive patients (11 men and 8 women; average age, 56.5 years). Nine patients (47.4%), 5 with coronary artery disease and 4 with dilated cardiomyopathy, had an ejection fraction of < 30%. The average operative time was 129 minutes. In 18 patients (94.7%), the transvenous lead system provided effective sensing, pacing, and defibrillation during intraoperative testing. In each of these cases, the defibrillation threshold was less than 18 J. In 1 patient (5.3%), it was necessary to switch to epicardial leads, which were implanted through a left thoracotomy. All patients were extubated in the recovery room. The average hospital stay was 8 days. There was no early mortality or morbidity. During a maximum follow-up period of 17 months (mean, 9.2 months), no sudden death occurred. The implantable system terminated 245 ventricular tachycardia episodes in 14 patients (73.7%) and 82 ventricular fibrillation episodes in 13 patients (68.4%). Two hundred eleven (86.1%) of the ventricular tachycardia episodes were resolved by antitachycardia pacing alone. In 2 patients (10.5%), the caval electrode became dislocated; repositioning of the electrode was followed by repeat defibrillation threshold evaluation. Our experience shows that the transvenous Medtronic Pacer Cardioverter Defibrillator System provides safe, effective treatment of ventricular tachyarrhythmias. Because the perioperative mortality and morbidity are extremely low, use of this device may be particularly beneficial in patients with a high operative risk. Moreover, the lower number of unpleasant therapeutic shocks should increase patient a acceptance of the device.
The efficacy of 27 respiration sensitive rate modulated pacemakers (Biorate RDP-3 Biotec) implanted in the left pectoral area was evaluated every 3 months during a mean follow-up period of 29 months (range 10-50 months). Rate modulation function was unchanged other than for three patients in whom the auxiliary leads became displaced. Two implants lost ventricular sensing in this nonprogrammable model. In all but the three patients, Holter monitoring demonstrated pacing rate variation corresponding to daily activity. Stress test duration increased from 8.2 +/- 1.5 minutes (in fixed rate VVI rate) to 12.83 +/- 2.0 minutes (in the VVIR mode) (P less than 0.05). Right arm movement increased the pacing rate by 5 +/- 3 beats/min (NS), while the left arm movement increase was 30 +/- 5 beats/min (P less than 0.05). Mental, arithmetic, and nifedipine tests did not change the rate modulated pacing rate. The system responded to a change in respiratory rate by an increase in stimulation rate. A satisfactory response in sensitivity and velocity was present only with medium-high workloads. Interference with rate modulation occurred with movement of the arm ipsilateral to the implanted pulse generator.
Recently the use of a new radioactive agent with physical and biological properties more favorable than those of thallium 201, methoxy-isobutyl-isonitrile (MIBI) labeled with technetium 99m (Tc 99m), has permitted simultaneous performance of perfusion and function studies in ischemic cardiopathy. Transesophageal atrial pacing (TAP) technique has evolved as an alternative provocative test of ischemia. The authors compared the capability of Tc 99m-MIBI myocardial scintigraphy, combined with TAP, with that of Tc 99m-MIBI, combined with maximal stress test, in the diagnosis of ischemic cardiopathy. They studied 11 patients with a clinical history of angina pectoris. Myocardial scintigraphy was performed at rest, after stress test, and after TAP. Finally, all the patients underwent coronary angiography. The analysis of myocardial perfusion images on both Tc 99m-MIBI associated with TAP and with stress demonstrated, in 165 myocardial segments examined: 143 normal, 20 reversible defects, 2 irreversible defects. The concordance of localization between coronarographic data and scintigraphic reversible and irreversible defects was 85%. In conclusion TAP proves to be a valid and sensitive provocative test of ischemia when combined with myocardial scintigraphy and with Tc 99m-MIBI.
The authors describe a cas of pacemaker malfunction due to a critical increase of impedance resulting from air entrapment in the pacemaker pocket.
The purpose of this study was to evaluate the usefulness of phase analysis in detecting the altered activation sequence induced by different pacing modes. Radionuclide ventriculography and planar gated blood pool scintigraphy were performed at rest in 56 patients with different pacemakers. This method permitted us to localize the pacemaker impulse site in the right ventricle and its diffusion in the heart. In patients with VVI pacemaker, this technique showed an evident asynchronism of contraction and relaxation of each ventricle and the standard deviation of phase angle (sigma), calculated by computer, is greater during pacing than sinus rhythm for left (LV) and right (RV) ventricles (LV sigma: 17 degrees +/- 4 vs 11 degrees +/- 3, less than 0.001; RV sigma: 31 degrees +/- 7 vs 14 degrees +/- 4, P less than 0.001). In the patients with VVI rate responsive pacemakers, the LV sigma changed from 18.5 +/- 3 under pacing to 11 degrees +/- 3 in sinus rhythm, P less than 0.001, while the RV sigma changed from 30 degrees +/- 8 to 14 degrees +/- 4, P less than 0.001. Instead in the patients with DDD pacemakers, the LV sigma changed from 15.5 degrees +/- 2 under pacing to 11 degrees +/- 3 in sinus rhythm, P less than 0.05, while the RV sigma changed from 29.1 degrees +/- 6 to 14 degrees +/- 4, P less than 0.001.(ABSTRACT TRUNCATED AT 250 WORDS)
It is very difficult to evaluate the ability of carrying out physical exercise in patients with rate responsive (RR) pacemaker (PM). However, the anaerobic threshold (AT) proved to be a useful parameter in the evaluation of cardiac function. The AT can be easily reproduced and not influenced from emotional aspects of both the patient and the physician, moreover being under maximum and then easy to achieve. Aims of our study were: to evaluate if the cardiopulmonary stress test can represent a method to be used for a more correct rate responsive pacemaker programming; to compare the data obtained of 3 rate responsive pacemakers steered by different sensors. We have studied 24 patients, of whom 10 with Activitrax (A), 8 with Meta (M), and 6 with Phymos MPT (P) pacemakers. Patients were submitted to symptoms limited cycloergometer stress test at 2 different settings: fixed rate at 70 b/min; increasing rate at until 85% of maximum heart rate for each patient, with range 0 + 10 W/min. Gas exchange data were continuously collected using an automated system (Medical Graphic System 2001) based on Whipp and Wasserman's method.(ABSTRACT TRUNCATED AT 250 WORDS)