PubMed Health⌕ Search

Biomedical subjects

C Perlick

Publications and source records attributed to C Perlick.

6 recordsLinked to original sources

Micromotion in cemented rotating platform total knee arthroplasty: cemented tibial stem versus hybrid fixation.

INTRODUCTION: Improving the longevity and reliability of cemented total knee arthroplasty (TKA) remains a major step to achieve. It is still unclear, whether a cemented tibial stem reduces micromotion of the tibial tray and produces therefore a better initial stability or not. The higher conformity of rotating platform design and the possible rotary forces to the tibial platform may produce higher micromotion when the tibial stem remains cementless (hybrid fixation). MATERIALS AND METHODS: An in vitro study was performed using the PFC mobile bearing tibial tray (DePuy, Warswa, IN, USA) to test the hypothesis that the addition of cement surrounding the tibial stem reduces micromotion of the tibial tray in cemented TKA with mobile bearing design. Ten tibial trays with mobile design were implanted in sawbones with a 3-mm cement mantle beneath the baseplate of the tibial tray and with or without the cemented stem. Tibial trays were loaded additionally in the ventral, lateral, medial and posterior positions with 2,500 N using the Zwick Z010 instrumentation and HBM pick up Hottinger Baldwin. RESULTS: In this study, a significant increased mean maximum liftoff was found when only cementing the tibial baseplate (hybrid fixation), compared to the fully cemented tibial tray (P<0.02). CONCLUSION: In conclusion, the stem of mobile bearing tibial components should be cemented to provide increased micromotion and earlier loosening.

Arthroplasty, Replacement, Knee↗

Intraoperative cutting errors in total knee arthroplasty.

INTRODUCTION: Precise reconstruction of leg alignment offers the best opportunity for achieving good long-term results in total knee arthroplasty (TKA). It was the aim of this study to evaluate the bone-cutting process as a potential source of inaccuracy in TKA. MATERIALS AND METHODS: In a consecutive series of 50 computer-assisted TKAs, cutting errors, which were defined as a difference between the cutting block position before sawing and the achieved resection plane afterwards, were measured for the distal femur and proximal tibia resection. Measurements were performed using a CT-based navigation system. RESULTS: For the distal femoral cut, there was a mean varus/valgus deviation of 0.6 degrees (SD+/-0.5 degrees ) and a mean flexion/extension deviation of 1.4 degrees (SD+/-1.3 degrees ). For the proximal tibia, varus/valgus alignment showed a mean deviation of 0.5 degrees (SD+/-0.5 degrees ). The mean sagittal variability was 1.0 degrees (SD+/-0.9 degrees ). Differences between the frontal and the sagittal plane were significant. CONCLUSION: To minimize cutting errors, techniques and instruments are needed which enable a more stable fixation of the cutting blocks or even more appropriate preparation instruments. Using a computer-assisted technique, the surgeon is aware of cutting errors occurring at each point of the operation and will therefore be able to correct these errors during surgery, while he is not aware of those errors with the conventional TKA technique.

Adult↗

Flexion gap configuration in total knee arthroplasty following high tibial osteotomy.

Previous reports have described the potentially compromising effect of a high tibial osteotomy (HTO) on the results of a subsequent total knee arthroplasty (TKA). Although the reasons are not clear, some authors reported problems in soft-tissue balancing. In a prospective study, 22 patients with an average interval of 5.8 years after closed-wedge HTO were operated for TKA. All operations were performed with a CT-free navigation system, and measurements of the extension and flexion gap were assessed. The intraoperative data were compared to a control group of 100 consecutive computer-assisted TKA without previous osteotomy. In the study group, a highly significant shift towards a medial opening of the flexion gap between the posterior condylar line and the tibial resection (study group 0.4+/-4.7 degrees medial opening versus control group 3.4+/-3.3 degrees lateral opening, p<0.001) was observed. In the study group, 10/22 showed a medial opening of the flexion gap compared to 11/100 in the control group. Surgeons should be aware of difficulties in soft-tissue balance in TKA following HTO, especially for the flexion gap configuration and the axial rotation of the femoral component.

Aged↗

Minimally invasive unicompartmental knee replacement with a nonimage-based navigation system.

In a prospective study, two groups of 20 unicompartmental knee replacements (UKR) each were operated either using a CT-free navigation system or the conventional minimal invasive technique. Radiographic assessment of postoperative alignment was performed by long-leg coronal and lateral radiographs. The results revealed a significant difference between the two groups in favor of navigation. In the computer-assisted group, 95% of UKRs were in a range of 4-0 degrees varus (mechanical axis) compared with 70% in the conventional group. The only inconvenience was a prolonged operation time (+19 min). Due to the limited exposure, the navigation system is helpful in achieving a more precise component orientation. The danger of overcorrection is diminished by real-time information about the leg axis at each step during the operation.

Aged↗

Radiological results of image-based and non-image-based computer-assisted total knee arthroplasty.

Restoration of the mechanical limb axis and accurate component orientation are two major factors affecting the long-term results after total knee replacement (TKR). Different navigation systems are available to improve the outcome. Image-based systems require pre-operative CT scans, while non-image-based systems gain all necessary information intra-operatively during a registration process. We studied 130 patients who received a TKR either using the CT-based (Knee 1.1) or the CT-free module (CT-free Knee 1.0) of the BrainLAB Vector-Vision Navigation System. Post-operative leg alignment and component orientation was determined on long-leg coronal and lateral X-rays. Sixty of 65 patients in the CT-based group and 63/65 patients in the CT-free group had a post-operative leg axis between 3 degrees varus/valgus. No significant differences were found for varus/valgus orientation of the femoral and tibial components.

Aged↗

Orthopaedic rehabilitation in a case of Tay-syndrome.

This paper reports on the orthopaedic rehabilitation of a patient with Tay-syndrome. Tay-syndrome is a rare monogen-inherited ektodermal dysplastic syndrome with ichtyosis, fragility of the hair and physical and mental retardation. The congenital ichtyosis is ubiquitous. Only the skin on the flexion side of the extremity joints are not involved (orthocerathosis combined with paraceratotic strings). In this case, a young boy developed bilateral subluxation of the hips and was not able to stand or walk freely. Contemporary pre- and neonatal care has prolonged the survival of newborns with severe genodermatoses, including this syndrome. In this case, it has provided the necessity for orthopaedic treatment of the problems caused by osteosclerosis and muscular spasticity.

Bacterial Infections↗