A randomized trial of 72- versus 24-hour intravenous tubing set changes in newborns receiving lipid therapy.

OBJECTIVE: To compare the microbial contamination rate of infusate in the intravenous tubing of newborns receiving lipid therapy, replacing the intravenous delivery system at 72-hour versus 24-hour intervals. DESIGN: Infants requiring intravenous lipid therapy were randomly assigned to have intravenous sets changed on a 72- or a 24-hour schedule, in a 3:1 ratio, in order to compare the infusate contamination rates in an equivalent number of tubing sets. SETTING: A 35-bed, teaching, referral, neonatal intensive-care unit (NICU). PARTICIPANTS: All neonates admitted to the NICU for whom intravenous lipid was ordered. METHODS: Patients were randomized in pharmacy, on receipt of the order for intravenous lipid therapy, to either 72- or 24-hour administration set changes, and followed until 1 week after discontinuation of lipids or discharge from the NICU. Microbial contamination of the infusate was assessed in both groups at the time of administration set changes. Contamination rates were analyzed separately for the lipid and amino acid-glucose tubing sets. Patient charts were reviewed for clinical and epidemiological data, including birth weight, gestational age, gender, age at start of lipid therapy, duration of parenteral nutrition, and type of intravenous access. RESULTS: During the study period, 1,101 and 1,112 sets were sampled in the 72- and 24-hour groups, respectively. Microbial contamination rates were higher in the 72-hour group than the 24-hour group for lipid infusions (39/1,101 [3.54%] vs 15/1,112 [1.35%]; P=.001) and for amino acid infusions (12/1,093 [1.10%] vs 4/1,103 [0.36%]; P=.076). Logistic regression analysis controlling for birth weight, gestational age, and type of venous access showed that only the tubing change interval was significantly associated with lipid set contaminations (odds ratio, 2.69; P=.0013). The rate of blood cultures ordered was higher in the 72- versus the 24-hour group (6.11 vs 4.99 per 100 patient days of total parenteral nutrition; P=.017), and a higher proportion of infants randomized to the 72-hour group died (8% vs 4%; P=.05), although the excess deaths could not clearly be attributed to bacteremia. CONCLUSION: Microbial contamination of infusion sets is significantly more frequent with 72- than with 24-hour set changes in neonates receiving lipid solutions. This may be associated with an increased mortality rate.

Bacteremia↗

Peripherally inserted central catheters in children.

PURPOSE: To assess the feasibility and complications of peripherally inserted central catheters (PICCs) in pediatric patients. MATERIALS AND METHODS: The authors attempted to place PICCs in 122 patients aged 9 days to 19 years (mean, 6.82 years; median, 5 years). Catheters were placed to allow prolonged administration of antibiotics or chemotherapeutic agents (n = 50), provide total parenteral nutrition (n = 41), and establish prolonged intravenous access for blood draws and fluid administration (n = 31). Silicone catheters measuring 3, 4, and 5 F were inserted in either basilic or cephalic veins and positioned at the junction of the superior vena cava and right atrium under fluoroscopic guidance. Patients were monitored for complications until devices were removed. RESULTS: Fluoroscopically guided PICC placement was successful in 137 of 148 attempts. Postinsertion complications included mechanical defects of the catheter, PICC-related infection, occlusion of the PICC, and venous stasis. Complications occurred at a rate comparable to those seen with blind insertion. CONCLUSION: Fluoroscopically guided PICC placement is feasible and safe in pediatric patients.

Adolescent↗