A new endotoxin adsorber: first clinical application.

In an open, uncontrolled pilot study, 5 men and 1 woman with suspected gram-negative sepsis were treated with a new whole-blood endotoxin adsorption system. Lipopolysaccharide (LPS) adsorption was carried out by hemoperfusion over high-affinity polymethacrylate-bound albumin (Fresenius Endotoxin Adsorber EN 500). All patients suffered from endotoxemia (>20 pg/ml LAL) and met at least two systemic inflammatory response syndrome (SIRS) criteria. Four patients suffered from pneumonia due to mechanical ventilation, one from peritonitis, and one from pneumonia and peritonitis. Endotoxin adsorption was very well tolerated, and efficient LPS removal was shown in all patients. Apache II score immediately before immunoadsorption was 23.5 and was 22.3 after the last treatment. All 6 critically ill patients improved substantially and were discharged from the intensive care unit. LPS whole blood immunoadsorption is a promising new method. No side effects have been observed thus far. A large controlled study to prove clinical efficacy in patients with severe sepsis is under way.

APACHE↗

Assessment of intrathoracic blood volume as an indicator of cardiac preload: single transpulmonary thermodilution technique versus assessment of pressure preload parameters derived from a pulmonary artery catheter.

OBJECTIVE: To analyze the clinical value of a new device (PiCCO) for cardiac output measurement and volume preload parameter assessment, based on transpulmonary thermodilution technique, as an alternative to the pulmonary artery thermodilution technique and assessment of pressure preload parameters derived from the pulmonary artery catheter. DESIGN: Prospective, controlled, clinical study. SETTING: University hospital. PARTICIPANTS: Eighteen patients with ejection fraction >50% undergoing coronary artery bypass graft surgery. INTERVENTIONS: A baseline measurement was performed after induction of anesthesia under clinical steady-state conditions (T1). Hypovolemia, defined as central venous pressure (CVP) <10 mmHg and pulmonary capillary wedge pressure (PCWP) <12 mmHg, was treated by infusion of 6% hydroxyethyl starch 200/0.5 (7 mL/kg). After 10 minutes, a second measurement (T2) was performed. MEASUREMENTS AND MAIN RESULTS: The mean difference (bias) between transpulmonary thermodilution cardiac output and pulmonary artery thermodilution cardiac output did not differ at the 2 sample points. Changes in pressure preload parameters of the pulmonary artery catheter (CVP, PCWP) did not correlate with changes in cardiac output or stroke volume, whereas changes in volume preload parameter intrathoracic blood volume (ITBV) of the PiCCO correlated significantly with changes in cardiac output and stroke volume (r = 0.55, p < 0.05; r = 0.62, p < 0.01). CONCLUSION: These results suggest that increased cardiac preload is more reliably reflected by ITBV than by CVP or PCWP. The assessment of ITBV by the transpulmonary single indicator dilution technique is an interesting alternative to the pressure preload parameters.

Adult↗

Continuous cardiac output measurement: pulse contour analysis vs thermodilution technique in cardiac surgical patients.

We have analysed the clinical agreement between two methods of continuous cardiac output measurement pulse contour analysis (PCCO) and a continuous thermodilution technique (CCO), were both compared with the intermittent bolus thermodilution technique (BCO). Measurements were performed in 26 cardiac surgical patients (groups 1 and 2, 13 patients each, with an ejection fraction > 45% and < 45%, respectively) at 12 selected times. During operation, mean differences (bias) between PCCO-BCO and CCO-BCO did not differ in either group. However, phenylephrine-induced increases in systemic vascular resistance (SVR) by approximately 60% resulted in significant differences. Significantly higher absolute bias values of PCCO-BCO compared with CCO-BCO were also found early after operation in the ICU. Thus PCCO and CCO provided comparable measurements during coronary bypass surgery. After marked changes in SVR, further calibration of the PCCO device is necessary.

Adult↗

[Experimental principles and general practice of intraoperative autotransfusion with blood irradiation in tumor operation].

Clinical studies fail to verify or to exclude the lethal risk of tumor spread after intraoperative autotransfusion in tumor surgery. An alternative approach is the development of methods for the elimination of tumor cells in the salvaged blood. The radiosensitivity of tumor cells especially in oxygenated single cell suspensions is well known, while the non-nucleated red blood cells are radioresistant. With 50 Gy a 12 log reduction in proliferating cells is expected. This we have tested experimentally and put into clinical practice. The suppression of colony formation in cell culture by irradiation with 50 Gy was tested with tumor cells from established cell lines or from solid tumors after admixture in high cell number to red blood cells from volunteer blood donations. DNA metabolism was tested by incorporation of bromodesoxyuridine (BrdUrd) and staining with mcab-anti-BrdUrd. Colony formation and DNA metabolism was absent in all samples of cell lines or tumor cells in blood after irradiation with 50 Gy, reflecting a 10 log, or 7 log reduction, respectively. In clinical practice the method of intraoperative blood salvage during tumor surgery with blood irradiation showed its practicability and efficacy in reducing homologous transfusions.

Adult↗

Diagnostic value of AgNOR staining in follicular cell neoplasms of the thyroid: comparison of evaluation methods and nucleolar features.

The diagnostic value of argyrophil staining of nucleolar organizer regions (AgNOR) was studied in 95 nonneoplastic and neoplastic follicular lesions of the thyroid. Different AgNOR parameters such as number, size, and distribution pattern were determined using digital image analysis. In addition, nuclear and nucleolar size as well as the percentage of nucleoli touching the nuclear membrane (nucleolar margination) were assessed. A stepwise increase in nuclear size and AgNOR counts from normal thyroid tissue to follicular adenoma as well as from differentiated follicular to anaplastic carcinoma was found (mean nuclear area [micron2]/mean AgNOR number per cell: 21.5/1.6 vs. 34.4/3.5 and 45.3/5.0 vs. 66.5/10.8, p < 0.01/p < 0.001). There was, however, no clear separation between these diagnostic groups. In contrast, an almost total discrimination between follicular adenoma and carcinoma was achieved by quantification of AgNORs per tumor cell nucleolus (AgNOR distribution score). In benign adenomas, 3.3% (range, 0-8.8%) of the cells showed nucleoli with at least five AgNOR dots within one focal plane, whereas in follicular carcinomas, the corresponding value was 34.1% (range, 12-75%). Two of four cases of so-called atypical adenomas showed values in the range of benign adenomas, and two were in the range of follicular carcinomas. In comparison with other nuclear and nucleolar parameters, the AgNOR distribution score proved the most valuable diagnostic criterion for the cytomorphological differentiation between follicular adenoma and carcinoma of the thyroid.

Adenocarcinoma, Follicular↗