Opportunistic bacteria in implant infections. Knowing them to plan their control.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to C R Arciola.
Explore the source record for details and available documents.
The vast use of prosthetic materials in medicine over the last decades has been accompanied by the appearance of new opportunistic pathogens previously considered incapable of causing infections with significant morbidity and/or mortality. In this regard, the genus Staphylococcus enlisting numerous species usually characterized by a saprophytic habit covers a special role. Apart from Staphylococcus aureus and Staphylococcus epidermidis, well known for their large prevalence in implant-related infections, a number of further staphylococcal species are progressively being indicated for their pathogenic potential. The increasing attention on these opportunistic bacteria is due to an ever growing number of clinical reports, which is also deriving from a more accurate identification of these species with currently available techniques. This synopsis intends to offer an overview on recently emerging coagulase-negative staphylococci (CoNS) as well as coagulase-positive/-variable staphylococci exhibiting distinct traits of virulence, pathogenicity, and epidemiologic impact depending among others on the medical field, the type of prosthetic device and its anatomic location.
Several species belonging to Staphylococcus genus (non Sau/ non Sep species) exhibit increasing abilities as opportunistic pathogens in colonisation of periprosthesis tissues. Here we report on antibiotic resistance of 193 strains, belonging to non Sau/ non Sep species, consecutively collected from orthopedic implant infections in a period of about 40 months. The 193 strains (representing 17% of all staphylococci isolated) were analysed for their antibiotic resistance to 16 different drugs. Five species turned out more prevalent, ranging from 1 to 5%: S. hominis (4.2%), S. haemolyticus (3.7%), S. capitis (2.7%), S. warneri (2.6%), and S. cohnii (1.6%). Among these, the prevalence of antibiotic resistance to penicillins was similar, ranging from 51% to 66%. Conversely, significant differences were observed for all the remaining antibiotics. For S. haemolyticus the resistances to oxacillin and imipenem, the four aminoglycosides and erythromycin were at least twice that of the other three species which were compared. S. warneri was on the contrary the species with the lowest occurrence of resistant strains. Ten species appeared only rarely at the infection sites: S. lugdunensis, S. caprae, S. equorum, S. intermedius, S. xylosus, S. simulans, S. saprophyticus, S. pasteuri, S. sciuri, and S. schleiferi. The behaviours of these species, often resistant to penicillins, were individually analysed. Differences in both the frequencies and the panels of antibiotic resistances observed among the non Sau/ non Sep species: i) suggest that horizontal spreading of resistance factors, if acting, was not sufficient per se to level their bio-diversities; ii) highlight and confirm the worrisome appearance within the Staphylococcus genus of emerging ""new pathogens"", not homogeneous for their virulence and antibiotic resistance prevalence, which deserve to be recognised and treated individually.
Enterococci are opportunistic pathogens which today represent one of the leading causes of nosocomial infections. We have examined a collection of 52 Enterococcus faecalis isolated from orthopedic infections to determine if they were characterized by a specific pattern of virulence factors. The isolates were evaluated for biofilm formation, presence of genes coding the enterococcal surface protein (esp) and gelatinase (gelE), as well as for gelatinase production. While the rate of esp-positive isolates was comparable to that found among strains from other clinical sources, we found a significantly higher rate of strong biofilm formers and gelatinase producers. Particularly high was the rate of gelE-carrying strains expressing the gene. Data suggest that these two factors in particular may play an important role in enterococcal infections associated with biomaterials.
There are numerous reports in the literature using animal models of osteomyelitis for investigating pathogenesis, diagnosis, and treatment of bone infections. Rabbits, rats, and dogs are commonly used animals, and, less frequently, chickens, guinea pigs, miniature pigs, goats, and sheep. Commonly used bones for creating local osteomyelitis include tibia, femur, and radius, and, less frequently, mandible and spine. When designing a specific model, one should consider which animal and which bone will be used, which route for inoculation (either local injection or systemically through vascular injection), which bacterial species and how many bacteria should be applied, if and what sclerosing agent, foreign body or implant should be employed, and if local trauma is needed. Basic methods of evaluation include clinical observation, radiography, microbiology, and histology.
Several species belonging to Staphylococcus genus, other than Staphylococcus aureus and Staphylococcus epidermidis (non Sau/ non Sep species), exhibit increasing abilities as opportunistic pathogens in the colonisation of periprosthetic tissues. Consequently, the availability of means for accurate identification is crucial to assess the pathogenic characteristics and to clarify clinical relevance of the individual species. Here, 146 clinical staphylococcal isolates belonging to non Sau/ non Sep species from prosthesis-associated orthopedic infections were analyzed by conventional enzymatic galleries and by automated ribotyping. Twelve different species were recognised: S. capitis, S. caprae, S. cohnii, S. equorum, S. haemolyticus, S. hominis, S. lugdunensis, S. pasteuri, S. sciuri, S. simulans, S. warneri, S. xylosus. Ribotype identifications were compared with the phenotypes obtained by the Api 20 Staph system and/or ID 32 Staph system. ID 32 Staph profiles were more consistent with ribotyping results than Api Staph profiles. Across the different staphylococcal species investigated, correct identifications with Api Staph were 45%, while with ID 32 Staph they were 59%. It has, however, to be mentioned that ID 32 Staph was mostly applied to discriminate unmatched ribotyping and Api Staph identifications, thus to a subpopulation of strains with ""atypical"" metabolic profile. Automated ribotyping provided a correct identification for 91% of the isolates. These results confirm automated ribotyping as a convenient rapid technique, still subject to improvements, which will accurately and rapidly recognise the newly emerging staphylococcal pathogens in implant-related orthopedic infections.
Titanium-based implants are successfully used for various biomedical applications. However, in some cases, e.g. in dental implants, failures due to bacterial colonization are reported. Surface modification is a commonly proposed strategy to prevent infections. In this work, titanium oxide, naturally occurring on the surface of titanium, was modified by promoting the formation of a mixed titanium and zinc oxide, on the basis of the idea that zinc oxide on titanium surface may act as the zinc oxide used in pharmaceutical formulation for its lenitive and antibacterial effects. The present work shows that it is possible to form a mixed titanium and zinc oxide on titanium surfaces, as shown by Scanning Electron Microscopy and XPS analysis. To this end titanium was preactivated by UV on crystalline titanium oxide, both in the anatase form or in the co-presence of anatase and rutile. By performing antibacterial assays, we provide evidence of a significant reduction in the viability of five streptococcal oral strains on titanium oxide surfaces modified with zinc. In conclusion, this type of chemical modification of titanium oxide surfaces with zinc might be considered a new way to reduce the risk of bacterial colonization, increasing the lifetime of dental system applications.
In natural and man-made environments, microbial communities thrive as biofilms on living (e.g. tissue) and inanimate (e.g. plastic, metal, wood, mineral) surfaces. Biofilms are found in a wide range of aqueous habitats, including physiological fluids. Numerous types of microorganisms are able to colonize catheters, implants, prosthetics, and other medical devices manufactured from different metallic and non-metallic materials dwelling within a human body. The development of biofilm is facilitated by the production of extracellular polymeric substances (EPS). Biofilms formed on surfaces of metallic materials may alter interfacial electrochemical processes, which can lead to increased corrosion of the colonized substratum. Deterioration of metallic materials in the presence of a biofilm is termed biocorrosion or microbially-influenced corrosion (MIC). In the field of biomaterials, ""biocorrosion"" is commonly used when describing the effect of host tissue on the corrosion of implant metals and alloys. Therefore, to avoid confusion, we will here use the term MIC as a reference to biofilm-influenced corrosion. It is important to realise that although most metals are prone to microbial colonization, i.e. to biofouling, this does not imply that they are susceptible to MIC. For example, a metal such as titanium, accumulates biofilm, however, it still demonstrates excellent resistance against MIC. Corrosion is, by definition, an electrochemical process, therefore, electrochemical techniques are frequently employed to determine and measure the rate of abiotic, as well as biologically driven corrosion reactions. This communication addresses the use of electrochemical techniques for monitoring (i) biofilm formation on and (ii) MIC of implant metals and alloys.
The possibility of biosurfaces with high or low adhesiveness for protein, bacteria or eukaryotic cells is discussed. At the interface surface object/biological milieu, biocompatibility, (no) bioadhesion and (no) biocontamination are shown to be correlated with physico-chemical surface characteristics. First consequence is the (no) possibility of biofilm formation. Substrates with low surface energy could interact only with hydrophobic biomolecules. On substrates with high surface energy, a water monolayer spontaneously formed. Modification of a surface by plasma techniques is a way for engineering biomaterials. Plasma techniques are dry processes and more suitable for biomedical applications. In the field of biomaterial medical devices, in hygienic prevention of nosocomial diseases, in food packaging, the use of substrates with a very hydrophilic character may help to prevent the proliferation of cells and bacteria. Such a technique is so efficient that antibiotic molecules are not necessary. Therefore, surface engineering is a tool for modifying and adapting materials to specific biological applications.
The production and the mechanism of action of exotoxins from Staphylococcus aureus, Staphylococcus epidermidis and Pseudomonas aeruginosa are presented. The attack to the immune host's defenses is the main virulence factor of opportunistic bacteria in implant infections, favoring the invasion and colonization of compromised periprosthesis tissues.
In recent years the progress in the field of nanotechnologies has offered new possibilities to control the superficial features of implant materials down to a nanoscale level. Several studies have therefore tried to explore the effects of nanostructured biomaterial surfaces on the behavior of eukaryotic cells. However, nanotopography could exert an influence also on the behavior of prokaryotic cells, with relevant implications concerning the susceptibility of implant surfaces to infection. Aim of this study was to examine the behavior of Staphylococcus aureus on polyethylene terephthalate (PET) surfaces either cylindrically nanostructured (PET-N) or flat ion-etched (PET-F), and on tissue culture-grade polystyrene (PS). Microbial adherence was assessed by chemiluminometry under 4 different conditions: (a) bacteria suspended in MEM medium, (b) bacteria in MEM supplemented with 10% fetal bovine serum (FBS), (c) test surfaces preconditioned in FBS, and (d) post-exposure of colonised surfaces to serum-supplemented MEM. Under all circumstances, PET-F and PET-N specimens showed identical bacterial adhesion properties. In the absence of serum, all 3 test materials showed a very high adhesivity to microbial cells and both PET surfaces exhibited greater adhesion than PS. On the contrary, the presence of 10% serum in solution significantly affected cell behavior: the number of microbial cells on all surfaces was drastically reduced, and the adhesion properties of PET surfaces with respect to PS were reversed, with PET being less adhesive. Overall, the specific cylindrical nanostructures created on PET did not significantly influence microbial behavior. Ongoing studies are verifying whether other nanotopographies with different geometry could have more substantial effects.
Stainless steel is a metallic alloy largely employed in orthopedics, maxillofacial surgery and orthodontic therapy. However, the presence in its composition of a high quantity of nickel, an agent known to trigger toxic, allergic and cancerogenous responses in humans, is cause of some concern. In this study, we have investigated the in vitro mutagenicity and genotoxicity of a new nickel-free stainless steel, namely P558, in comparison to the conventional stainless steel AISI 316L. The cytogenetic effects were evaluated by studying the frequency of Sister Chromatid Exchanges (SCE) and chromosomal aberrations. Ames test was performed to detect the mutagenic activity. Both P558 and AISI 316L did not cause any significant increase in the average number of SCE and in chromosomal aberrations, either with or without metabolic activation. Furthermore, the Ames test showed that the extracts of both P558 and of AISI 316L are not mutagenic. Overall, these findings prove that P558 is devoid of genotoxicity and mutagenicity. The present results, together with other previous interesting observations that P558 promotes osseointegration, suggest that this new nickel-free stainless steel can represent a better alternative to other conventional steel alloys.
Explore the source record for details and available documents.
A significant proportion of medical implants become the focus of a device-related infection, difficult to eradicate because bacteria that cause these infections live in well-developed biofilms. Biofilm is a microbial derived sessile community characterized by cells that are irreversibly attached to a substratum or interface to each other, embedded in a matrix of extracellular polymeric substances that they have produced. Bacterial adherence and biofilm production proceed in two steps: first, an attachment to a surface and, second, a cell-to-cell adhesion, with pluristratification of bacteria onto the artificial surface. The first step requires the mediation of bacterial surface proteins, the cardinal of which is similar to S. aureus autolysin and is denominated AtlE. In staphylococci the matrix of extracellular polymeric substances of biofilm is a polymer of beta-1,6-linked N-acetylglucosamine (PIA), whose synthesis is mediated by the ica operon. Biofilm formation is partially controlled by quorum sensing, an interbacterial communication mechanism dependent on population density. The principal implants that can be compromised by biofilm associated infections are: central venous catheters, heart valves, ventricular assist devices, coronary stents, neurosurgical ventricular shunts, implantable neurological stimulators, arthro-prostheses, fracture-fixation devices, inflatable penile implants, breast implants, cochlear implants, intraocular lenses, dental implants. Biofilms play an important role in the spread of antibiotic resistance. Within the high dense bacterial population, efficient horizontal transfer of resistance and virulence genes takes place. In the future, treatments that inhibit the transcription of biofilm controlling genes might be a successful strategy in inhibiting these infections.A significant proportion of medical implants become the focus of a device-related infection, difficult to eradicate because bacteria that cause these infections live in well-developed biofilms. Biofilm is a microbial derived sessile community characterized by cells that are irreversibly attached to a substratum or interface to each other, embedded in a matrix of extracellular polymeric substances that they have produced. Bacterial adherence and biofilm production proceed in two steps: first, an attachment to a surface and, second, a cell-to-cell adhesion, with pluristratification of bacteria onto the artificial surface. The first step requires the mediation of bacterial surface proteins, the cardinal of which is similar to S. aureus autolysin and is denominated AtlE. In staphylococci the matrix of extracellular polymeric substances of biofilm is a polymer of beta-1,6-linked N-acetylglucosamine (PIA), whose synthesis is mediated by the ica operon. Biofilm formation is partially controlled by quorum sensing, an interbacterial communication mechanism dependent on population density. The principal implants that can be compromised by biofilm associated infections are: central venous catheters, heart valves, ventricular assist devices, coronary stents, neurosurgical ventricular shunts, implantable neurological stimulators, arthro-prostheses, fracture-fixation devices, inflatable penile implants, breast implants, cochlear implants, intra-ocular lenses, dental implants. Biofilms play an important role in the spread of antibiotic resistance. Within the high dense bacterial population, efficient horizontal transfer of resistance and virulence genes takes place. In the future, treatments that inhibit the transcription of biofilm controlling genes might be a successful strategy in inhibiting these infections.
In spite of the recent achievements derived from modern protocols of prophylaxis, orthopedic surgical infections still remain unacceptably frequent, especially in light of the often devastating outcomes of septic complications. The spectrum and the prevalence of the bacteria most frequently involved in orthopedic infections are here explored, with particular reference to those infections associated to implant biomaterials, which were grouped based on device typology. During a 30 months period (from September 2000 to April 2003), 1027 microbial strains were consecutively isolated from 699 patients undergoing revision surgery at the Rizzoli Orthopedic Institute. 775 (75.5%) of all these microorganisms were identified as belonging to the Staphylococcus genus, 82 (8%) to the Enterobacteriaceae family, 75 (7.3%) to the Pseudomonas genus, 54 (5.3%) to the Enterococcus genus and 20 (1.9%) to the Streptococcus genus. While confirming the importance of staphylococci as the most diffuse cause of infection, our data indicate an unexpectedly high prevalence of S. epidermidis on infected hip and knee arthroprostheses, respectively of 42% and 44%. The spectrum of bacteria infecting either internal or external fracture fixation devices appears to differ from that of hip and knee arthroprostheses and more closely resembles that of infections non-associated to medical devices, being characterized by a relatively higher prevalence of Staphylococcus aureus (over 40%) and Pseudomonas aeruginosa. Enterobacteriaceae and members of the Streptococcus and Corynebacterium genera are frequently associated with implants in which surgical incisions were made near the perineum, determining a completely altered spectrum.
Enterococci are commensals of human and animal intestinal tract that have emerged in the last decades as a major cause of nosocomial infections of bloodstream, urinary tract and in infected surgical sites. Enterococcus faecalis is responsible for ca. 80% of all enterococcal infections while Enterococcus faecium accounts for most of the others; among the most relevant risk factors for development of enterococcal infections is the presence of implanted devices. The pathogenesis of such infections is poorly understood, but several virulence factors have been proposed. Among them, the ability to form biofilm has recently been shown to be one of the most prominent features of this microorganism, allowing colonization of inert and biological surfaces, while protecting against antimicrobial substances, and mediating adhesion and invasion of host cells and survival within professional phagocytes. Biofilm formation has been shown to be particularly important in the development of prosthetic valve enterococcal endocarditis and stent occlusion. Enterococci are also able to express other surface factors that may support colonization of both inert and biological surfaces, and that may be involved in the invasion of, and survival within, the host cell.
Implant infection is an aggressive, often irreducible post-surgical infection. It remains the primary cause of implant failure. Bacterial contamination during surgery and subsequent adhesion onto biomaterial surface of opportunistic microorganisms, such as staphylococcal species, exopolysaccharidic slimes or specific adhesins, initiates the implant infection. Pathogenesis of periprosthestic infection is the focus of studies aimed at developing infection resistant materials.
This article concisely reviews the effects of sterilization on the mechanical properties and surface chemistries of implantable biomaterials. This article also summarizes the biological effects of the sterilization-related changes in the implant. Because there are so many different types of implant materials currently in use (including metals, polymers, and diverse biological materials), the response of tissue to these different materials varies dramatically. This review further discusses the effects of sterilization on in vivo and in vitro tissue response specifically to implantable metals and polyethylene, with the possibility of future biocompatibility testing of the implants sterilized with supercritical phase carbon dioxide sterilization.