PubMed HealthSearch

Biomedical subjects

C R Bellina

Publications and source records attributed to C R Bellina.

15 recordsLinked to original sources

Myocardial perfusion abnormalities in chronic Chagas' disease as detected by thallium-201 scintigraphy.

Most patients with chronic Chagas' heart disease complain of chest pain. The pathophysiology of this symptom is unknown, although myocardial necrosis and fibrosis are frequent necropsy findings and cardiac autonomic impairment is a prominent feature of the disease. To evaluate the possibility of an ischemic cause for these abnormalities in 23 patients (18 men, aged 32 to 60 years, mean 42) with chronic Chagas' disease complaining of chest pain, thallium-201 myocardial scintigraphy was performed after maximal effort and 4-hour redistribution. Regional wall motion was assessed by radionuclide and contrast angiography. Heart rate responses to sinus respiratory arrhythmia, atropine, phenylephrine and Valsalva maneuver were evaluated in all patients and in 22 normal control subjects. Coronary angiography was performed in 16 patients. Only 1 patient had chest pain and no ischemic electrocardiographic changes occurred in any case during the effort test. Scintigraphic analysis of 7 segments per patient showed perfusion defects in at least 1 segment in all patients. Of 161 myocardial segments 16 showed fixed, 10 reversible, and 22 paradox defects (reverse redistribution). The majority (75%) of the fixed perfusion defects occurred in dyssynergic regions, whereas reverse redistribution predominated in regions with normal wall motion (82%). The reversible defects were present in normal or mildly hypokinetic regions. Markedly impaired parasympathetic cardiac control was present but no significant coronary abnormalities were seen in any of the 16 patients undergoing angiography. It is concluded that whereas fixed defects are likely to correspond to fibrotic or necrotic lesions, reversible and paradox perfusion defects may be caused by regional flow or metabolism derangements, possibly related to abnormal parasympathetic control of the coronary microcirculation.

Adult

Evaluation of reconstructed scatter fraction on PET images.

This paper describes a procedure proposed for the quantitative evaluation of the influence of the scattering noise on the reconstructed PET images. Applying the same experimental procedure used to evaluate the Scatter Fraction (SF) on the sinograms obtained measuring line sources within a uniform scattering medium, the method here proposed permits the computation, after reconstruction, of a derived index of the SF i.e. the Reconstructed Scatter Fraction (RSF). This offers the advantage of providing an estimate of the scatter noise directly on the images obtained in the same processing conditions as during the in vivo human studies. Comparative data of SF and RSF are reported as well as the effect of varying the filter function and of the measured attenuation correction on the RSF. The preliminary results obtained show that the values of the reconstructed scatter fraction are closer to the SF ones when this last is computed only in the cylinder region and the RSF is computed on images reconstructed with a ramp filter.

Evaluation Studies as Topic

User-friendly image processing software tools: general purpose features and application to the correlation of PET-CT brain images.

An interactive software package, performing some useful general purpose image processing operations and being used as a tool for the problem of the anatomical correlation of PET brain images, is under development. The software is developed as a comprehensive tool with a graphic user-interface allowing the display of the processed images through the use of a variety of colormaps. The implemented routines perform a lot of processing operations on the images: a) Local image processing, i.e. smoothing and sharpening, contours extraction, interactive expansion, shrinking and thresholding of the gray scale, histogram equalization. b) ROI handling, i.e., ROI drawing and computing, transformation of an image to a ROI, ROI editing. c) Additional operators include frequency space image processing such as FFT.

Brain

Simultaneous in vitro and in vivo validation of nitrogen-13-ammonia for the assessment of regional myocardial blood flow.

Measurement of myocardial blood flow by 13NH3 relies heavily on the assessment of both the input function and the variable tissue extraction fraction. In six open-chest dogs, myocardial and arterial 13NH3 activity was measured both by in vitro sampling and by in vivo positron emission tomography (PET). Regional myocardial blood flow was forced to vary in the range 0.2-5 ml/min/g and actual values were assessed by in vitro counting of 153Gd microspheres. The ammonia input function was processed by: (a) total curve integration; (b) curve integration for 2 min; (c) integral of a fitted curve (gamma variate in vivo and exponential of the downslope in vitro). Method C brought to regional flow values which best approximated microspheres data. The in vitro correlation allows for correcting in vivo values for the flow-dependent extraction fraction. The method can be easily applied for regional myocardial blood flow measurements with PET in human studies.

Algorithms

Measurement of resolution and recovery in recent generation positron tomographs.

In positron tomographic images, the ability to differentiate closely lying structures, the spillover of activity from a region into adjacent regions and the reduction in apparent isotope concentration in small structures are all dependent on spatial resolution. Resolution in the reconstructed image is affected by (i) detector size, (ii) the spatial sampling used (e.g. stationary, wobble), (iii) the amount of smoothing in the reconstruction process (or subsequent to reconstruction) and (iv) the image pixel size. Under ideal conditions, modern commercial tomographs can produce a reconstructed spatial resolution of 5 mm or less. However, this is rarely realizable in a clinical study due to the inadequacy of counting statistics and the amplification of statistical noise. In practice, a smoother filter has to be used. This paper presents a summary of practical measurements of spatial resolution, and the related count recovery, performed on recent generation positron tomographs. It is intended to contribute to the definition of methods of measuring these parameters which is part of an on going concerted action in positron tomography supported by the European Commission.

Image Processing, Computer-Assisted

Coronary hemodynamics and myocardial metabolism during and after pacing stress in normal humans.

We investigated coronary hemodynamics, myocardial utilization of circulating substrates (by coronary sinus catheterization), and overall use of oxidative fuels (by regional indirect calorimetry) in healthy adults during incremental atrial pacing (up to 159 +/- 9 beats/min), and during 25 min of recovery. Great cardiac vein flow (thermodilution) increased from 52 +/- 9 to 115 +/- 15 ml/min (P less than 0.001) with pacing; myocardial O2 uptake (301 +/- 53 to 593 +/- 71 mumol/min, P less than 0.001) and CO2 production (225 +/- 37 to 518 +/- 66 mumol/min, P less than 0.005) paralleled the pacing-induced rise in rate-pressure product (9.4 +/- 0.9 to 21.1 +/- 1.1 mmHg.beat. min-1.10(-3), P less than 0.001). During recovery, all the above variables returned to base line within 5 min, but myocardial O2 extraction remained depressed (67 +/- 2 vs. 71 +/- 3%, P less than 0.05). Circulating glucose uptake rose linearly with pacing (P less than 0.05) and remained above base line throughout recovery. By contrast, free fatty acid (FFA) uptake (10 mumol/min) did not increase with pacing and fell during recovery (P less than 0.01). Calorimetry, however, showed that net lipid oxidation exceeded FFA uptake throughout the study, whereas net carbohydrate oxidation was small at base line, rose significantly at maximal pacing (62% of myocardial energy output), and remained above base line during recovery (32% of energy output). In the basal state as well as during recovery, myocardial uptake of glucose equivalents (lactate plus glucose plus pyruvate) was in excess of carbohydrate oxidation, indicating nonoxidative disposal of these substrates.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult

Intrapleural liquid flow down a gravity-dependent hydraulic pressure gradient.

We studied the vertical movement of 2 mg technetium-labeled albumin injected intrapleurally in 0.5 ml saline (15% of pleural liquid volume) in eight spontaneously breathing anesthetized dogs subject to a sudden change in posture (prone to supine or vice versa). The albumin movements were evaluated through a large field gamma camera placed laterally to the animal and detecting total (AT) and regional activities from two superimposed equal areas (At and Ab, top and bottom, respectively). The At/Ab ratio decreased from 2.1 to 1.3 in four animals up to 20 min from the change in posture and from 0.9 to 0.5 in four more animals studied from 50 to 90 min from turning maneuver. The rate of change in At and Ab was similar in the two groups of animals and unaffected by the acquisition posture. AT decreased by 7.7 and 3.5% for the two groups, respectively, reflecting albumin clearance from the pleural space. The opposite time course of regional activities and the independence of their rate of change of the At/Ab ratio and of the animal posture suggest a top-to-bottom albumin transfer occurring through a bulk flow of liquid estimated at 0.006 ml.kg-1.h-1. The data are consistent with a measured vertical pleural liquid pressure gradient that does not reflect a hydrostatic condition.

Animals

Pulmonary retention of iodobenzyl-propanediamine in humans. Effect of cigarette smoking.

N,N,N'-trimethyl-N'-(2-hydroxy-3-methyl-5-iodobenzyl)-1,3-propanediamine (HIPDM), a synthetic basic compound with high affinity for lung tissue of various animal species, was labeled with 123I and injected into normal smokers (n = 9) and into asymptomatic smokers (n = 9). Time/activity curves were recorded for 90 min by gamma camera. HIPDM lung clearance was described by two exponential components. In smokers, the mean time of the first component, 10 +/- 1.4 min (mean +/- SEM), did not significantly differ from that of nonsmokers (9.7 +/- 0.9 min), whereas the mean time of the second component (12.9 +/- 0.6 h) was longer than that of nonsmokers (6.7 +/- 0.2 h). The intercept to the ordinate of the second exponential component was significantly higher in smokers (90.3 +/- 1.5%) than in nonsmokers (80.7 +/- 1.9%). Control studies in rabbits showed that, 2 min after intravenous injection, 95% of HIPDM is taken up by the lung; time/activity curves were similar to those obtained in humans. The longer pulmonary persistence of HIPDM in smokers may reflect an increased number of cellular binding sites or may be the expression of hindered HIPDM biotransformation. The rabbit can be used as a model to further investigate HIPDM kinetics in relation to lung dysfunction.

Adolescent

Performance characteristics of a whole-body positron tomograph.

This paper describes an investigation of some of the important physical characteristics of a whole-body positron tomograph consisting of two rings of bismuth germanate detectors of dimensions 5.6 mm X 30 mm X 30 mm (512/ring). The resolution applicable to in vivo imaging is six mm or more, depending on radionuclide and reconstruction filter and is very uniform over the field of view normally used. Axial resolution can be varied by moving side collimation (maximum approximately 16 mm FWHM with interplane septa). A simple scheme has been devised to correct for loss of true coincidence events with varying count rate based on the total random and multiple coincidence rates. It is concluded that correction for scattered radiation should be implemented for reliable quantitation.

Humans

An electronic "diaphragm" for the gamma camera, with adjustable zooming and offset.

We describe a new device for data acquisition from a gamma camera using an electronic spatial "diaphragm," with variable offset and zooming. The device, mainly applied to cardiac studies, permits selection of the desired part of the field of vision to be digitized and to zoom, before the computer acquisition. The spatial diaphragm spans 0.4-0.9 of the diameter of the FOV, and the amplification factor from 1.1 to 2.5.

Computers