PubMed Health⌕ Search

Biomedical subjects

C R Jacobs

Publications and source records attributed to C R Jacobs.

At least 19 recordsLinked to original sources

Osteopontin gene regulation by oscillatory fluid flow via intracellular calcium mobilization and activation of mitogen-activated protein kinase in MC3T3-E1 osteoblasts.

Recently fluid flow has been shown to be a potent physical stimulus in the regulation of bone cell metabolism. However, most investigators have applied steady or pulsing flow profiles rather than oscillatory fluid flow, which occurs in vivo because of mechanical loading. Here oscillatory fluid flow was demonstrated to be a potentially important physical signal for loading-induced changes in bone cell metabolism. We selected three well known biological response variables including intracellular calcium (Ca(2+)i), mitogen-activated protein kinase (MAPK) activity, and osteopontin (OPN) mRNA levels to examine the response of MC3T3-E1 osteoblastic cells to oscillatory fluid flow with shear stresses ranging from 2 to -2 Newtons/m(2) at 1 Hz, which is in the range expected to occur during routine physical activities. Our results showed that within 1 min, oscillatory flow induced cell Ca(2+)i mobilization, whereas two MAPKs (ERK and p38) were activated over a 2-h time frame. However, there was no activation of JNK. Furthermore 2 h of oscillatory fluid flow increased steady-state OPN mRNA expression levels by approximately 4-fold, 24 h after exposure to fluid flow. The presence of both ERK and p38 inhibitors and thapsigargin completely abolished the effect of oscillatory flow on steady-state OPN mRNA levels. In addition, experiments using a variety of pharmacological agents suggest that oscillatory flow induces Ca(2+)i mobilization via the L-type voltage-operated calcium channel and the inositol 1,4,5-trisphosphate pathway.

3T3 Cells↗

Oscillating fluid flow regulates cytosolic calcium concentration in bovine articular chondrocytes.

Mechanical loading is a well-known regulator of cartilage metabolism. This suggests that a loading-induced physical signal regulates chondrocyte behavior. Previous studies have focused on the effects of steady fluid flow on chondrocytes. In contrast to steady flow, loading induced fluid flow occurs in an oscillatory pattern and includes a reversal of flow direction with each loading event. In this study we examined the hypothesis that oscillating fluid flow increases cytosolic Ca2+ concentration ([Ca2+]i) in bovine articular chondrocytes (BAC) in a frequency-dependent manner and that the presence of serum affects this response. The aims of our study were to examine (1) whether BAC respond to physiologic oscillating fluid flow in vitro and compare these results to steady fluid flow, (2) the effect of fetal bovine serum on fluid flow responsiveness of BAC and (3) whether the response of BAC to fluid flow is flow rate and/or frequency dependent. [Ca2+]i was quantified using the fluorescent dye fura-2. BAC were exposed to steady, 0.5, 1, or 5 Hz sinusoidal oscillating fluid flow at five different flow rates in a parallel plate flow chamber. Our findings demonstrate that BAC respond to oscillating fluid flow with an increase in [Ca2+]i (p > 0.05), and furthermore, chondrocyte responsiveness to fluid flow increases with peak flow rate (p < 0.0001) and decreases with increasing frequencies (p < 0.0001). Finally, the presence of serum in the media potentiated the responsiveness of BAC to fluid flow (p < 0.0001). Our results suggest an important role for mechanical load-induced oscillating fluid flow in chondrocyte mechanotransduction.

Animals↗

Flow-induced calcium oscillations in rat osteoblasts are age, loading frequency, and shear stress dependent.

Bone adaptation to mechanical loading is dependent on age and the frequency and magnitude of loading. It is believed that load-induced fluid flow in the porous spaces of bone is an important signal that influences bone cell metabolism and bone adaptation. We used fluid flow-induced shear stress as a mechanical stimulus to study intracellular calcium (Ca) signaling in rat osteoblastic cells (ROB) isolated from young, mature, and old animals. Fluid flow produced higher magnitude and more abundant [Ca(2+)](i) oscillations than spontaneous oscillations, suggesting that flow-induced Ca signaling encodes a different cellular message than spontaneous oscillations. ROB from old rats showed less basal [Ca(2+)](i) activity and were less responsive to fluid flow. Cells were more responsive to 0.2 Hz than to 1 or 2 Hz and to 2 Pa than to 1 Pa. These data suggest that the frequency and magnitude of mechanical loading may be encoded by the percentage of cells displaying [Ca(2+)](i) oscillations but that the ability to transduce this information may be altered with age.

Aging↗

Gap junctions and fluid flow response in MC3T3-E1 cells.

In the current study, we examined the role of gap junctions in oscillatory fluid flow-induced changes in intracellular Ca(2+) concentration and prostaglandin release in osteoblastic cells. This work was completed in MC3T3-E1 cells with intact gap junctional communication as well as in MC3T3-E1 cells rendered communication deficient through expression of a dominant-negative connexin. Our results demonstrate that MC3T3-E1 cells with intact gap junctions respond to oscillatory fluid flow with significant increases in prostaglandin E(2) (PGE(2)) release, whereas cells with diminished gap junctional communication do not. Furthermore, we found that cytosolic Ca(2+) (Ca) response was unaltered by the disruption in gap junctional communication and was not significantly different among the cell lines. Thus our results suggest that gap junctions contribute to the PGE(2) but not to the Ca response to oscillatory fluid flow. These findings implicate gap junctional intercellular communication (GJIC) in bone cell ensemble responsiveness to oscillatory fluid flow and suggest that gap junctions and GJIC play a pivotal role in mechanotransduction mechanisms in bone.

Animals↗

Aged bone displays an increased responsiveness to low-intensity resistance exercise.

The ability of bone to respond to increased loading as a function of age was tested by use of three-point bending and histomorphometry. The hindlimbs of male Fischer 344 rats of three age groups (young = 4 mo, adult = 12 mo, and old = 22 mo; n = 10 per age group) were progressively overloaded by training the rats to depress a lever high on the side of a cage while wearing a weighted backpack. This squatlike movement required full extension of the hindlimbs. Exercised (Exer) rats performed 50 repetitions three times per week for 9 wk. Pack weight was gradually increased to 65% of body weight. Controls (n = 10 per age group) performed the same exercise without additional weight. Neither the mechanical properties of the femur nor histomorphometry in the proximal tibia was significantly affected in young or adult rats. However, old Exer rats were found to have significantly smaller medullary areas and a decreased trabecular spacing than their age-matched controls. These results suggest a greater sensitivity to increased loading in aged rats.

Aging↗

Oscillating fluid flow inhibits TNF-alpha -induced NF-kappa B activation via an Ikappa B kinase pathway in osteoblast-like UMR106 cells.

Fluid flow plays an important role in load-induced bone remodeling. However, the molecular mechanism of flow-induced signal transduction in osteoblasts remains unclear. In endothelial cells, fluid flow alters activation of NF-kappaB resulting in changes in expression of cell adhesion molecules. To test the hypothesis that fluid flow alters NF-kappaB activation and expression of cell adhesion molecules in osteoblastic cells, we examined the effect of oscillating fluid flow (OFF) on tumor necrosis factor (TNF)-alpha-induced NF-kappaB activation in rat osteoblast-like UMR106 cells. We found that OFF inhibits NF-kappaB-DNA binding activities, especially TNF-alpha-induced p50-p65 heterodimer NF-kappaB activation and TNF-alpha-induced intercellular adhesion molecule-1 mRNA expression. The inhibitory effects of OFF on both TNF-alpha-induced NF-kappaB activation and intercellular adhesion molecule-1 mRNA expression were shear stress-dependent and also increased with OFF exposure duration, indicating that OFF has potent effects on mechanotransduction pathways. OFF also inhibited TNF-alpha-induced IkappaBalpha degradation and TNF-alpha-induced IkappaB kinase (IKK) activity in a shear stress-dependent manner. These results demonstrate that IKK is an initial target molecule for OFF effects on osteoblastic cells. Thus, OFF inhibits TNF-alpha-induced IKK activation, leading to a decrease in phosphorylation and degradation of inhibitory IkappaBalpha, which in turn results in the decrease of TNF-alpha-induced NF-kappaB activation and potentially the transcription of target genes.

Animals↗

Substrate deformation levels associated with routine physical activity are less stimulatory to bone cells relative to loading-induced oscillatory fluid flow.

Although it is well accepted that bone tissue metabolism is regulated by external mechanical loads, it remains unclear to what load-induced physical signals bone cells respond. In this study, a novel computer-controlled stretch device and parallel plate flow chamber were employed to investigate cytosolic calcium (Ca2+i) mobilization in response to a range of dynamic substrate strain levels (0.1-10 percent, 1 Hz) and oscillating fluid flow (2 N/m2, 1 Hz). In addition, we quantified the effect of dynamic substrate strain and oscillating fluid flow on the expression of mRNA for the bone matrix protein osteopontin (OPN). Our data demonstrate that continuum strain levels observed for routine physical activities (< 0.5 percent) do not induce Ca2+i responses in osteoblastic cells in vitro. However, there was a significant increase in the number of responding cells at larger strain levels. Moreover, we found no change in osteopontin mRNA level in response to 0.5 percent strain at 1 Hz. In contrast, oscillating fluid flow predicted to occur in the lacunar-canalicular system due to routine physical activities (2 N/m2, 1 Hz) caused significant increases in both Ca2+i and OPN mRNA. These data suggest that, relative to fluid flow, substrate deformation may play less of a role in bone cell mechanotransduction associated with bone adaptation to routine loads.

Animals↗

Functional gap junctions between osteocytic and osteoblastic cells.

Morphological evidence shows that osteocytes, bone cells that exist enclosed within bone matrix, are connected to one another and to surface osteoblasts via gap junctions; however, it is unknown whether these gap junctions are functional. Using a newly established murine osteocytic cell line MLO-Y4, we have examined functional gap junctional intercellular communication (GJIC) between osteocytic cells and between osteocytic and osteoblastic cells. In our hands, MLO-Y4 cells express phenotypic characteristics of osteocytic cells including a stellate morphology, low alkaline phosphatase activity, and increased osteocalcin messenger RNA (mRNA) compared with osteoblastic cells. Northern and Western blot analysis revealed that MLO-Y4 cells express abundant connexin 43 (Cx43) mRNA and protein, respectively. Lucifer yellow dye transferred from injected to adjacent cells suggesting that osteocytic cells were functionally coupled via gap junctions. Functional GJIC between osteocytic and osteoblastic (MC3T3-E1) cells was determined by monitoring the passage of calcein dye between the two cell types using a double labeling technique. The ability of bone cells to communicate a mechanical signal was assessed by mechanically deforming the cell membrane of single MLO-Y4 cells, cocultured with MC3T3-E1 cells. Deformation induced calcium signals in MLO-Y4 cells and those elicited in neighboring MC3T3-E1 cells were monitored with the calcium sensitive dye Fura-2. Our results suggest that osteocytic MLO-Y4 cells express functional gap junctions most likely composed of Cx43. Furthermore, osteocytic and osteoblastic cells are functionally coupled to one another via gap junctions as shown by the ability of calcein to pass between cells and the ability of cells to communicate a mechanically induced calcium response.

Animals↗

Bone structural and mechanical properties are affected by hypotransferrinemia but not by iron deficiency in mice.

Hypotransferrinemia is a genetic defect in mice resulting in <1% of normal plasma transferrin (Tf) concentrations; heterozygotes for this mutation (+/hpx) have low circulating Tf concentrations. We used this mutant mouse in conjunction with dietary iron deficiency to study the influence of Tf and iron on bone structural and mechanical properties. Twenty-one weanling wild-type BALB/cj +/+ mice and 21 weanling +/hpx mice were fed iron-deficient or iron-adequate diets for 8 weeks. Twelve hpx/hpx mice were fed the iron-adequate diet. Hypotransferrinemia resulted in increased tibia iron and calcium concentrations, lower femur failure load, and extrinsic stiffness. Because the femurs of the hpx/hpx mice were disproportionately small, these bones actually had increased tissue material properties (ultimate stress [US] and modulus of elasticity) than those of wild-type mice. This is the first report on the effect of dietary iron deficiency on bone structural and mechanical properties. Dietary iron deficiency in +/+ and +/hpx mice decreased tibia iron concentrations but had no effect on tibia calcium and phosphorus concentrations or femur structural or mechanical properties. Because the bones of the hpx/hpx mice were small, but had superior tissue mechanical properties, we conclude that Tf is important for normal bone mineralization.

Animals↗

The consequences of anterior femoral notching in total knee arthroplasty. A biomechanical study.

BACKGROUND: Notching of the anterior femoral cortex during total knee arthroplasty has been implicated as a cause of subsequent periprosthetic supracondylar femoral fracture. However, other than observational clinical data, no reliable association between these events has been established, to our knowledge. The purpose of the present study was to investigate the biomechanical effects of notching of the anterior femoral cortex. METHODS: The femoral component of a total knee replacement was implanted in twelve matched pairs of human cadaveric femora; one specimen in each pair had preservation of the anterior femoral cortex, and the other had a full-thickness cortical defect created just proximal to the anterior flange of the femoral component. The pairs were then subjected to either bending or torsional loading to failure. Both the fracture pattern and the quantitative load to failure were analyzed. Two matched pairs were excluded from the analysis because of inadvertent fracture during placement of the component. RESULTS: Following the application of a bending load, femora with notching of the anterior femoral cortex sustained a short oblique fracture that originated at the cortical defect proximal to the femoral component and femora without notching had a midshaft fracture. In contrast, notching of the anterior femoral cortex had no effect on the fracture pattern that was observed after the application of a torsional load. The mean load to failure was significantly reduced by notching in both testing modes. Notching decreased bending strength from 11,813 to 9690 newtons (18 percent; p = 0.0034), and it decreased torsional strength from 134.7 to 81.8 newton-meters (39.2 percent; p = 0.01). CONCLUSIONS: Biomechanical testing demonstrated that notching of the anterior femoral cortex significantly lessens the load to failure following total knee arthroplasty and influences the subsequent fracture pattern. These effects are manifested in different ways under the two loading conditions: the fracture pattern is altered under bending load, and there is a greater quantitative decrease in load to failure with torsional loading. CLINICAL RELEVANCE: Weakening of the femur by notching of the anterior cortex after total knee arthroplasty may warrant alteration in the customary postoperative regimen for these patients. Manipulation of a total knee replacement with a notched anterior femoral cortex should probably be avoided.

Aged↗

Mechanisms contributing to fluid-flow-induced Ca2+ mobilization in articular chondrocytes.

We previously showed that fluid flow, which chondrocytes experience in vivo and which results in a variety of morphological and metabolic changes in cultured articular chondrocytes, can also stimulate a rise in intracellular calcium concentration ([Ca2+]i). However, the mechanism by which Ca2+ is mobilized in response to flow is unclear. In this study, we investigated the roles of intracellular Ca2+ stores, G-proteins, and extracellular ATP in the flow-induced Ca2+ response in bovine articular chondrocytes (BAC). Cells loaded with the Ca2+ sensitive dye Fura-2 were exposed to steady flow at 34 ml/min (37 dynes/cm2) in a parallel plate flow chamber. Whereas ryanodine and caffeine had no effect, both neomycin and thapsigargin significantly decreased the Ca2+(i) response to flow, suggesting a role for Ca2+ store release, possibly through an inositol 1,4,5-trisphosphate (IP3)-dependent mechanism. Twenty-four-hour treatment with pertussis toxin also significantly decreased the response, suggesting that the mechanism may be G-protein regulated. In addition, ATP release by chondrocytes does not appear to mediate the flow-induced Ca2+ response because suramin, a P2 purinergic blocker, had no effect. These results suggest that BAC respond rapidly to changes in their mechanical environment, such as increased fluid flow, by a mechanism that involves IP3 stimulated Ca2+(i) release and G-protein activation.

Adenosine Triphosphate↗

Tension and bending, but not compression alone determine the functional adaptation of subchondral bone in incongruous joints.

In the present study, we tested the hypothesis that tension and bending, rather than compression alone, determine the functional adaptation of subchondral bone in incongruous joints. We investigated whether tensile stresses in the subchondral bone of the humero-ulnar articulation are affected by the direction of muscle and joint forces, and whether the tensile stresses are large enough to cause microstructural adaptation, specifically a preferential alignment of the trabeculae and the subchondral collagen fibres. Using a previously validated finite element model of the human humero-ulnar joint, we calculated the contact pressure, the principal compressive and tensile stresses, and the strain energy density in the subchondral bone for various flexion angles. A bicentric (ventro-dorsal) pressure distribution was found in the joint at 30 degrees to 120 degrees of flexion, with contact pressures of up to between 2.5 and 3 MPa in the ventral and dorsal aspects of the ulnar joint surface, but less than 0.5 MPa in the centre. The principal tensile stress in the subchondral bone of the trochlear notch quantitatively exceeded the principal compressive stress at low flexion angles (maximum 8.2 MPa), and the distribution of subchondral strain energy density differed substantially from that of the contact stress (r=-0.72 at 30 degrees and r=+0.58 at 90 degrees of flexion). No important tensile stress was computed in the trochlea humeri. On contact radiography, we found sagittally orientated subarticular trabeculae in the notch, running tangential to the surface. Furthermore, we observed sagittally orientated split lines in the subchondral bone of the notch of 20 cadaver joints, suggesting a ventro-dorsal orientation of the collagen fibres. The trochlea humeri, on the other hand, did not show a preferential direction of the subchondral split lines, these findings confirming the predictions of tensile stresses in the model. We conclude that, due to the important contribution of tension to subchondral bone stress, the distribution of subchondral density cannot be directly employed for assessing the long term distribution of joint pressure at the cartilage surface. The magnitude of the tensional stress varies considerably with the direction of the muscle and joint forces, and it appears large enough to cause functional adaptation of the subchondral bone on a microstructural level.

Adaptation, Physiological↗

NACOB presentation to ASB Young Scientist Award: Postdoctoral. The impact of boundary conditions and mesh size on the accuracy of cancellous bone tissue modulus determination using large-scale finite-element modeling. North American Congress on Biomechanics.

The apparent properties of cancellous bone are determined by a combination of both hard tissue properties and microstructural organization. A method is desired to extract the underlying hard tissue properties from simple mechanical tests, free from the complications of microstructure. It has been suggested that microCT voxel-based large-scale finite element models could be employed to accomplish this goal (van Rietbergen et al., 1995, Journal of Biomechanics, 28, 69-81). This approach has recently been implemented and it is becoming increasingly popular as finite element models increase in size and sophistication (Fyhrie et al., 1997, Proceedings of the 43rd Annual Meeting of the Orthopaedic Research Society, San Francisco, CA, p. 815; van Rietbergen et al., 1997, Proceedings of the 43rd Annual Meeting of the Orthopaedic Research Society, San Francisco, CA, p. 62). However, no direct quantitative measurements of the accuracy of this method applied to porous structures such as cancellous bone have been made. This project demonstrates the feasibility of this approach by quantifying its best-case accuracy in determining the trabecular hard tissue modulus of analogues fabricated of a material with known material properties determined independently by direct testing. In addition we were able to assess the impact of mesh size and boundary conditions on accuracy. We found that the assumption of a frictionless boundary condition in the parallel plate compression loading configuration was a significant source of error that could be overcome with the use of rigid end-caps similar to those used by Keaveny et al. (1997 Journal of Orthopaedic Research, 15(1), 101-110). In conclusion, we found that this approach is an effective method for determining the average trabecular hard tissue properties of human cancellous bone with an expected practical accuracy level better than 5%.

Awards and Prizes↗

Microcatheter adhesion of cyanoacrylates: comparison of normal butyl cyanoacrylate to 2-hexyl cyanoacrylate.

PURPOSE: To compare the catheter adhesion properties of 2-hexyl cyanoacrylate (Neuracryl M), a new agent, to those of normal butyl cyanoacrylate (Histoacryl), the most widely used liquid acrylic agent for microcatheter embolization. MATERIALS AND METHODS: 2-hexyl cyanoacrylate (Neuracryl M1) was tested in pure form and mixed with either a proprietary polymerization retardant/contrast agent (Neuracryl M2) or ethiodized oil (Ethiodol). Histoacryl was tested in pure form and mixed with Ethiodol. The cyanoacrylate mixtures were injected through microcatheters into wells partially filled with heparinized whole blood. The cyanoacrylates were allowed to polymerize around the microcatheter tips for 1-3 minutes. The microcatheters were then pulled at a constant rate until they were extracted from the polymerized cyanoacrylates. The peak forces required for extraction were recorded. RESULTS: The peak forces required to extract the microcatheters from either pure Histoacryl or Histoacryl mixed with 33% Ethiodol were significantly higher (P < .01; P < .05) than those for pure Neuracryl M1. When Neuracryl M1 and M2 were mixed together (as intended for clinical use), the force required for microcatheter extraction was significantly lower than that for either pure Histoacryl, Histoacryl mixed with 33% Ethiodol, or Neuracryl M1 alone (P < .01; P < .01; P < .01, respectively). The force required to extract microcatheters from the Neuracryl M1 and M2 mixture was not, however, significantly different from that of Histoacryl mixed with 50% Ethiodol. The force of extraction for the Neuracryl M1 and 50% Ethiodol mixture was below our ability to obtain precise measurements. CONCLUSION: When Neuracryl M1 was mixed with its proprietary polymerization retardant/contrast agent (Neuracryl M2), catheter adhesion was not significantly different from that of Histoacryl mixed with 50% Ethiodol, a mixture common in clinical use. When Neuracryl M1 was tested alone or mixed with Ethiodol (not intended by the manufacturer), catheter adhesion was significantly decreased relative to pure Histoacryl or equivalent mixtures of Histoacryl and Ethiodol.

Adhesiveness↗

Differential effect of steady versus oscillating flow on bone cells.

Loading induced fluid flow has recently been proposed as an important biophysical signal in bone mechanotransduction. Fluid flow resulting from activities which load the skeleton such as standing, locomotion, or postural muscle activity are predicted to be dynamic in nature and include a relatively small static component. However, in vitro fluid flow experiments with bone cells to date have been conducted using steady or pulsing flow profiles only. In this study we exposed osteoblast-like hFOB 1.19 cells (immortalized human fetal osteoblasts) to precisely controlled dynamic fluid flow profiles of saline supplemented with 2% fetal bovine serum while monitoring intracellular calcium concentration with the fluorescent dye fura-2. Applied flows included steady flow resulting in a wall shear stress of 2 N m(-2), oscillating flow (+/-2 Nm(-2)), and pulsing flow (0 to 2 N m(-2)). The dynamic flows were applied with sinusoidal profiles of 0.5, 1.0, and 2.0 Hz. We found that oscillating flow was a much less potent stimulator of bone cells than either steady or pulsing flow. Furthermore, a decrease in responsiveness with increasing frequency was observed for the dynamic flows. In both cases a reduction in responsiveness coincides with a reduction in the net fluid transport of the flow profile. Thus. these findings support the hypothesis that the response of bone cells to fluid flow is dependent on chemotransport effects.

Calcium Signaling↗

Plating techniques and plate orientation in repair of mandibular angle fractures: an in vitro study.

A biomechanical model utilizing polystyrene mandibles was devised to evaluate the fixation efficacy of various plating techniques for repair of mandibular angle fractures. A simple angle fracture was created in the mandible models at a standardized location and was repaired using five different plating techniques. Each experimental group consisted of 15 mandibles, with fracture site, plate placement, load application, and fracture displacement measurement standardized to ensure consistency among experimental groups. Measurement of fracture distraction under load application generated a load deformation curve and corresponding slope for each technique. Comparison of load deformation slopes allowed assessment of fixation stability. When applied with a subapical, medially placed monocortical tension band, bicortical compression plating demonstrated the most stable fracture fixation. The data show that biplanar plate placement in both monocortical noncompression and bicortical compression techniques yields a stronger fixation than monoplanar placement.

Biomechanical Phenomena↗

Computer simulation of subchondral bone adaptation to mechanical loading in an incongruous joint.

BACKGROUND: We hypothesized that the typically bicentric distribution of subchondral bone density (i.e., two maxima) in incongruous joints with deeper sockets could be predicted by a computer simulation employing a concavely incongruous finite-element model and current bone remodeling theory. Additional objectives were to assess the uniqueness of the solution with respect to assumed model parameters and initial conditions and to determine the relationship between contact areas, subchondral bone stress, and subchondral bone density patterns. METHODS: An idealized model of the humeroulnar joint was constructed with a quantitatively realistic representation of its natural incongruity. A currently accepted remodeling theory was implemented with a finite-element code using a node-based approach. RESULTS: The simulation predicted a dense subchondral bone plate after application of 3,000 daily load cycles for 300 days. The pronounced bicentric distribution of subchondral mineralization emerged. The solution was virtually independent of the initial density distribution and other assumed model parameters. Furthermore, the model predicted high tensile stresses in the subchondral bone, when the joint socket was spread apart during loading. Therefore, the locations of maximal strain energy density in the subchondral bone did not correspond with areas of joint contact. CONCLUSIONS: The results of the bone remodeling simulations are consistent with patterns of subchondral bone density determined experimentally. Furthermore, the solutions exhibited a high degree of uniqueness, were rather insensitive to changes in cartilage stiffness, moderately sensitive to number of applied loading cycles, and highly sensitive to loading magnitude. Tensile stresses seem to play a dominant role in subchondral bone remodeling due to bending in the subchondral bone plate. Thus, we conclude that, in the case of an incongruous joints with deeper sockets, the density of the subchondral bone cannot be regarded as a direct measure of the adjacent articular pressure.

Adaptation, Physiological↗