Effect of extracorporeal membrane oxygenation on left ventricular function of swine.

BACKGROUND: Previous clinical and experimental investigations have produced inconsistent data describing the effects of veno-arterial extracorporeal membrane oxygenation (VA ECMO) on intrinsic left ventricular (LV) function. We report an animal model that allows investigation of the effects of VA ECMO on the mechanics of the LV using two load-insensitive indices: end-systolic pressure-minor axis dimension relationship (ESPDR) and preload recruitable dimensional stroke work (PRDSW). METHODS: Eight piglets (5 to 11 kg) were anesthetized, instrumented, and placed on VA ECMO. Throughout the experiment, systemic and left atrial partial pressure of oxygen were maintained between 100 to 200 mm Hg. At ECMO flow rate of 50% of baseline cardiac output, data were collected prior to ECMO, at 4 and 6 hours during ECMO, and after weaning from ECMO. Data measured or calculated for each time point included heart rate, LV pressures and minor axis dimensions at different pre-loads, first derivative of LV pressure with respect to time, velocity of circumferential fiber length shortening (VCF), LV shortening fraction (LVSF), ESPDR, and PRDSW. RESULTS: A significant (p < 0.05) decrease in LVSF and VCF was seen at 4 and 6 hours during ECMO when compared to baseline, but the ESPDR and PRDSW did not change during ECMO. CONCLUSIONS: VA ECMO alone changes some of the load-dependent parameters of contractility, but intrinsic function of the heart is not significantly affected as measured by load-insensitive indices of LV performance.

Animals↗

Hyperthermic intraoperative intraperitoneal chemotherapy for peritoneal carcinomatosis and sarcomatosis using a cardioplegia heat exchanger and a two-pump system: a case report.

A 34-year-old male diagnosed with pseudomyxoma peritoneii presented for an exploratory laparotomy and hyperthermic intraoperative intraperitoneal chemotherapy. A circuit using two roller pumps and a cardioplegia administration set was assembled to deliver the chemotherapy perfusate at a consistent temperature. The authors discuss a case in which this treatment modality was used, describing the perfusionist's role and the circuit design.

Adult↗

A second-generation blood substitute (perfluorodichlorooctane emulsion) does not activate complement during an ex vivo circulation model of bypass.

OBJECTIVES: To examine whether a second-generation perfluorocarbon (PFC) blood substitute added to the cardiopulmonary bypass (CPB) prime influences complement production. DESIGN: A prospective, randomized, single-blinded, ex vivo model. SETTING: A university hospital, laboratory, and clinics. PARTICIPANTS: Ten healthy adult consented volunteer blood donors (five men, five women). INTERVENTIONS: Ex vivo closed-loop extracorporeal circuit including membrane oxygenator, tubing, and filter primed with crystalloid or crystalloid plus PFC was circulated for 1 hour with the addition of 500 mL of heparinized fresh human whole blood. MEASUREMENTS AND MAIN RESULTS: Laboratory specimens were drawn from the circuit at 10-minute intervals for 1 hour and measured for complement (C3a, Bb fragment) concentrations, blood gases, fibrinogen concentration, platelet count, and hematocrit. In the PFC group, C3a and Bb fragments were equal to or less than those in the group that received crystalloid alone. CONCLUSION: The second-generation PFC added to the prime of a CPB circuit does not independently increase complement production.

Adolescent↗

Perfluorocarbon emulsion in the cardiopulmonary bypass prime reduces neurologic injury.

BACKGROUND: Perfluorocarbon emulsion has proved beneficial in the prevention and amelioration of experimental air embolism. We examined whether the addition of perfluorocarbon to the prime solution could lead to a reduction in the incidence and severity of neurologic injury after the formation of a massive air embolism during cardiopulmonary bypass. METHODS: Fourteen pigs underwent bypass in which either a crystalloid prime solution or a perfluorocarbon prime solution (10 mL/kg) was used. Ten minutes into bypass a bolus (5 mL/kg) of air or saline (control) was delivered via the carotid artery. The resulting cerebral infarcts were graded on the basis of the findings in triphenyltetrazolium chloride-stained cerebral sections. Colored microspheres were used to measure cerebral blood flow. Bitemporal electroencephalography was used to evaluate cerebral function. RESULTS: Cerebral infarction was not found in the perfluorocarbon-air group (0 to 5 animals), as compared with its occurrence in 3 of the 5 animals in the crystalloid-air group. Cerebral blood flow was also maintained or increased in the perfluorocarbon-air group (p < 0.05), and the electroencephalogram total power showed less of a decrease and recovered more completely (p < 0.05) than it did in the crystalloid-air group. CONCLUSIONS: The addition of perfluorocarbon emulsion to the cardiopulmonary bypass prime solution leads to a reduction in the incidence and severity of neurologic injury after the formation of a massive air embolism during bypass.

Animals↗

An in vitro evaluation of an automatic clamp for use with centrifugal pumps.

The risk of air emboli is a concern for all perfusionists. A new clamping device for use with centrifugal pumps is designed to clamp both the arterial and venous lines at the first indication of air or retrograde flow, thereby allowing the perfusionist to evaluate the situation and correct the problem before entraining air into the arterial pump head. After evaluating this device in our lab, we conclude that this new safety device should be added to the heart lung machine by all perfusionists using centrifugal pumps.

Cardiopulmonary Bypass↗

An in vitro comparison of gas transfer and pressure drop of the Bentley Duraflo Coated Spiral Gold and the Medtronic Carmeda Coated Maxima hollow fiber membrane oxygenators.

Two models of heparin coated, hollow fiber membrane oxygenators were tested in vitro to compare gas transfer and transoxygenator pressure drop using an established protocol. Oxygen and carbon dioxide transfer rates were measured at blood flows of 2.5 and 5.0 liters per minute with gas flow: blood flow ratios of 1:1 and 2:1 at both blood flows. All testing was performed under normothermic conditions. The data shows that oxygen transfer increases as blood flow is increased in both oxygenators. Similarly, carbon dioxide transfer is increased by both increased blood and gas flows. Finally, the pressure drop was dependent on blood flow rate alone. This study demonstrated these two oxygenators to be comparable in both oxygen and carbon dioxide transfer and also in transoxygenator pressure drop.

Animals↗

An in vitro protocol for evaluation and comparison of membrane oxygenators.

With the trend in open heart surgery toward normothermic bypass and warm blood cardioplegia, greater demand is being placed on the perfusionist to select an oxygenator that will perform safely and efficiently under a variety of conditions. While manufacturers report performance parameters for their products, the data is often not comparable due to widely differing conditions. Recent in vitro evaluation techniques employed to characterize membrane oxygenators do not simulate the actual oxygenator conditions observed during cardiopulmonary bypass. Biocompatibility and drug delivery are reported but comparisons of different oxygenator performance parameters are not completely addressed. We have designed a test circuit and an evaluation protocol to simultaneously characterize the performance of multiple oxygenators under identical conditions. The test circuit is designed to simulate clinical conditions and to evaluate gas exchange, blood path pressures, gas path pressures, and hemolysis. Previously reported studies have relied on a comparison of a single membrane oxygenator and a single bubble oxygenator. Our protocol will compare multiple membrane oxygenators, in vitro, under similar clinically relevant conditions. Such testing would be done prior to animal or clinical trials. Furthermore in vitro tests should be more reproducible and more discriminating than are ex vivo tests.

Equipment Design↗