PubMed Health⌕ Search

Biomedical subjects

C Ramanathan

Publications and source records attributed to C Ramanathan.

15 recordsLinked to original sources

Entanglement assisted metrology.

We propose a new approach to the measurement of a single spin state, based on nuclear magnetic resonance (NMR) techniques and inspired by the coherent control over many-body systems envisaged by quantum information processing. A single target spin is coupled via the magnetic dipolar interaction to a large ensemble of spins. Applying radio frequency pulses, we can control the evolution so that the spin ensemble reaches one of two orthogonal states whose collective properties differ depending on the state of the target spin and are easily measured. We first describe this measurement process using quantum gates; then we show how equivalent schemes can be defined in terms of the Hamiltonian and thus implemented under conditions of real control, using well established NMR techniques. We demonstrate this method with a proof of principle experiment in ensemble liquid state NMR and simulations for small spin systems.

Journal Article↗

Spin diffusion of correlated two-spin states in a dielectric crystal.

Reciprocal space measurements of spin diffusion in a single crystal of calcium fluoride (CaF2) have been extended to dipolar ordered states. The experimental results for the component of the spin diffusion rate parallel to the external field are D(parallel)(D)=29+/-3x10(-12) cm(2)/s for the [001] direction and D(parallel)(D)=33+/-4x10(-12) cm(2)/s for the [111] direction. The measured diffusion rates for dipolar order are faster than those for Zeeman order and are considerably faster than predicted by simple theoretical models. It is suggested that constructive interference in the transport of the two-spin states is responsible for this enhancement. As expected, the anisotropy in the diffusion rates is observed to be significantly less for dipolar order compared to the Zeeman case.

Journal Article↗

Pulse error compensating symmetric magic-echo trains.

We present improved line-narrowing sequences for dipolar coupled spin systems, based on a train of magic-echoes which are compensated for the effects of finite pulse widths and utilize symmetry properties of supercycles. Sequences are introduced for spectroscopy and imaging by proper choice of a phase alternating scheme. Using a 16 pulse time-suspension magic-echo cycle, the highest level of line-narrowing achieved was 2.7 Hz for the [100] direction of a single crystal of calcium fluoride, a reduction in linewidth by 4 orders of magnitude.

Journal Article↗

Mapping the absolute value of M0 using dipolar field effects.

The ability to map the spatial variation of the absolute, rather than the relative value of the equilibrium magnetization could be advantageous in many areas of NMR. However, direct measurement of M(0) is usually difficult because of the multiparametric dependence of the NMR signal. Here we propose a technique for mapping the spatial variation of the absolute value of M(0), independent of relaxation weighting and flip angle calibration. This method, which works best at high field strengths, is based on the effect of the dipolar field due to the nuclear magnetization that is normally neglected in liquid-state NMR. The experimental implementation of this sequence at 3.0 T is described, and its initial application to the measurement of the water content of brain tissue is outlined.

Brain↗

Method for measuring local hydraulic permeability using magnetic resonance imaging.

The hydraulic permeability of a porous medium characterizes the ease with which a fluid may be driven through it, and is defined via the classical Darcy law. A method for noninvasive, nondestructive measurement of one projection of the local permeability tensor of a porous medium, using gas phase magnetic resonance imaging, is presented. Results are shown for one-dimensional experiments on dry porous rocks. The limitations of the method are explored, and the extension to three-dimensional imaging of the permeability is discussed.

Journal Article↗

Imaging the long-range dipolar field in structured liquid state samples.

We describe imaging experiments in which the pattern of the dipolar field generated by spatially modulated nuclear magnetization is directly visualized in simply structured phantoms. Two types of experiment have been carried out at 11.7 T using (1)H NMR signals. In the first, the field from a single spin species is imaged via its own NMR signal. In the second, the NMR signal from one spin species is used to image the field generated by a second species. The field patterns measured in these experiments correspond well with those calculated using simple theoretical expressions for the dipolar field. The results also directly demonstrate the spatial sensitivity of the signal generated using dipolar field effects, indicating that the range of the field depends upon the inverse of the spatial frequency with which the magnetization is modulated.

Journal Article↗

Fat emulsification measured using NMR transverse relaxation.

This paper presents a novel method of measuring the droplet size in oil-in-water emulsions. It is based on changes in the NMR transverse relaxation rate due to the effect of microscopic magnetic susceptibility differences between fat droplets and the surrounding water. The longitudinal and transverse relaxation rates of a series of emulsions with constant oil volume fraction and five different mean droplet sizes, in the range 0.4-20.9 microm, were measured in vitro at 37 degrees C using EPI. While the longitudinal relaxation rate 1/T(1) did not change significantly, 1/T(2) was observed to increase with mean droplet size. The measured changes in 1/T(2) were found to be in good agreement with results predicted from proton random walk simulations, and were also consistent with analytical solutions based on an outer sphere relaxation model. Measurements of 1/T(2) on emulsions with a higher oil volume fraction, and on emulsions of a fixed size where the water phase was doped with gadolinium to modulate the susceptibility difference between the phases, also showed the predicted behavior. As part of this study the susceptibility difference between olive oil and water was measured to be 1.55 ppm.

Algorithms↗

Electrocardiographic imaging: I. Effect of torso inhomogeneities on body surface electrocardiographic potentials.

INTRODUCTION: Body surface potential maps (BSPMs) and conventional ECG reflect electrical sources generated by cardiac excitation and repolarization and noninvasively provide important diagnostic information about the electrical state of the heart. Because the heart is located within the torso volume conductor, body surface potentials also reflect the effects of torso inhomogeneities, which include blood, lungs, bone, muscle, fat, and fluid. It is necessary to characterize and understand these effects in order to interpret BSPM and ECG in terms of cardiac activity without "contamination" from the inhomogeneous volume conductor. METHODS AND RESULTS: Actual measured epicardial and body surface potentials were obtained during normal sinus rhythm and for different pacing protocols from a Langendorff-perfused dog heart suspended in a human-shaped torso tank. Accurate geometry of the torso inhomogeneities was digitized from the Visual Human Project and appropriately introduced into a computer model of the tank setup. The geometry and electrical properties of the volume conductor could be varied. Both homogeneous and inhomogeneous torsos have major smoothing effects on BSPM, which is of very low resolution compared with its corresponding epicardial potential pattern. Relative to a homogeneous torso, the inhomogeneities have only a minor effect on BSPM patterns. They augment potential magnitudes depending on the pattern of epicardial activation. Variations of geometry and electrical properties within the normal physiologic range have minimal effects. CONCLUSION: Effects of torso inhomogeneities on 12-lead ECGs are minimal, and the associated ECG changes fall within the range of normal interindividual variations.

Algorithms↗

Electrocardiographic imaging: II. Effect of torso inhomogeneities on noninvasive reconstruction of epicardial potentials, electrograms, and isochrones.

INTRODUCTION: Noninvasive electrocardiographic imaging (ECGI) involves inverse reconstruction of epicardial potentials, electrograms (EGMs), and isochrones from body surface potential maps (BSPMs). The heart lies in a volume conductor that includes lungs, blood, bone, muscle, and fluid. We investigate the effects of these torso inhomogeneities on reconstructed epicardial potentials, EGMs, and isochrones to address the issue of whether they should be included in clinical ECGI methodology. METHODS AND RESULTS: Potential data were obtained for different pacing protocols from a dog heart suspended in a human-shaped torso tank. Accurate geometry of torso inhomogeneities was digitized from the Visual Human Project and appropriately introduced into a computer model of the torso. Three models were used: accurate inhomogeneous torso, homogeneous torso, and a torso with stylized lungs (to generate an approximate model). The inhomogeneous model was used to compute BSPMs from the measured epicardial potentials. These BSPMs were the starting point for inverse computations in the different torso models. Epicardial potential maps, EGMs, and isochrones were computed. The homogeneous model produced slightly less accurate epicardial potential reconstructions than the inhomogeneous model and stylized lung model, but epicardial potential patterns, EGMs, isochrones, and locations of pacing sites were reconstructed with comparable accuracy when torso inhomogeneities were ignored. CONCLUSION: The results demonstrate that, in the clinical application, it is not necessary to include torso inhomogeneities for noninvasive reconstructions of epicardial potentials, EGMs, and activation sequences.

Animals↗

Quantitative solid-state NMR imaging of synthetic calcium phosphate implants.

It is shown that solid-state phosphorus-31 nuclear magnetic resonance imaging can be used to measure quantitatively the mass of hydroxyapatite (HA), a synthetic calcium phosphate used as an orthopedic implant material, in the presence of bone. A three-dimensional projection reconstruction technique was used to produce solid-state images from 998 free induction decays sampled in the presence of a fixed amplitude field gradient whose direction was varied uniformly over the unit sphere. Chemical selection is achieved using T1 contrast, as the synthetic calcium phosphate has a shorter T1 (1.8 sec at 4.7 T) compared with the bone (approximately 15 sec at 4.7 T in vivo, 42 sec ex vivo). Experimental results demonstrating the linear relationship between image intensity and HA density in phantoms containing HA and silicon (IV) oxide, and HA and bone are shown. Chemically pure images of bone mineral and synthetic HA have been computed from images of New Zealand White rabbits acquired in vivo at two different recycle times. The technique can be used to follow noninvasively the resorption and remodeling of calcium phosphate implants in vivo.

Animals↗

ADRF differential cross polarization spectroscopy of synthetic calcium phosphates and bone mineral.

An adiabatic demagnetization in the rotating frame (ADRF) differential cross polarization (DCP), or inversion recovery cross polarization (IRCP), technique has been developed to study synthetic calcium phosphates and bone mineral. ADRF of the protons followed by a remagnetization of the phosphorus-31 spins results in an equalization of the dipolar and phosphorus Zeeman nuclear spin temperatures. By shifting the phase of the phosphorus RF by 180 degrees during the forward cross polarization it is possible to invert the temperature of this reservoir and initiate reverse cross polarization. Transient Strombotne-Hahn oscillations were observed on inverting the temperature. The presence of these oscillations complicates the determination of a null point on the basis of cross polarization times. It is necessary to shift the phase of the RF only after a Zeeman spin temperature can be defined, and to use an RF field strength that is slightly smaller than the equivalent S-spin local dipolar field in order to produce a zero crossing after the transient oscillations have decayed.

Animals↗

Scald burns in children caused by hot drinks--the importance of the type of cup.

A prospective study of 36 consecutive scald injuries in children caused by hot beverages is reported. Almost a third of these were deep dermal or full skin thickness and the highest percentage resulted in injury to the upper chest region. The study further investigates the cooling characteristics in four different types of cup. These studies clearly show the potential for significant disfigurement from this type of injury for up to 11 min from the time the drink is poured. The need for greater public awareness in relation to hot drinks is highlighted.

Accidents, Home↗

Desensitisation.

Explore the source record for details and available documents.

Desensitization, Immunologic↗

Direct measurement of porous media local hydrodynamical permeability using gas MRI.

The concept of hydraulic permeability is at the core of modeling single phase or multi-phase flow in heterogeneous porous media, as it is the spatial distribution of the permeability that primarily governs the behavior of fluid flow in the medium. To date, the modeling of fluid flow in porous media has been hampered by poor estimates of local permeability. Magnetic Resonance Imaging is well known for its ability to measure non-invasively the local density and flow rate of different fluids saturating porous media [1,2]. In this paper we demonstrate the first non-invasive method for the direct measurement of a single projection of the local permeability tensor of a porous medium using gas-phase MRI. The potential for three-dimensional imaging of the medium permeability is also discussed. The limitations of the method are listed and results are presented in a model porous medium as well as in a real oil reservoir rock.

Magnetic Resonance Imaging↗

Measuring spatially resolved gas transport and adsorption in coal using MRI.

The storage and transport of gases in coal is of tremendous importance in the utilisation of coalbeds, and in particular the recovery of methane. There is also increasing interest in the use of coal mines as sites for carbon dioxide sequestration to alleviate the potentially harmful effects of global warming. This paper demonstrates the use of magnetic resonance imaging to investigate the spatiotemporal dynamics of gas transport in coal. The presence of significant structural heterogeneities in the coal was observed. Dynamical effects displayed a broad range of time constants ranging from minutes to days.

Absorption↗