PubMed Health⌕ Search

Biomedical subjects

C Ramon

Publications and source records attributed to C Ramon.

At least 19 recordsLinked to original sources

Multimodal imaging of somatosensory evoked cortical activity.

Somatosensory evoked cortical activity is well investigated in both fMRI and MEG/EEG. Investigation with functional magnetic resonance spectroscopic (fMRS) imaging is relatively new and provides a means to image the metabolic activity of the brain. We for the first time combined fMRS, fMRI, MEG and EEG. This provides information about the metabolic, hemodynamic and electrical activity of the brain and also the verification of one imaging modality with the other. The dipolar source localized from the EEG/MEG data is in the vicinity of the fMRI activation site and also in the same area where lactate consumption is high as measured with fMRS imaging.

Electroencephalography↗

Effect of model complexity on EEG source localizations.

How model complexity influences the EEG source localizations was studied with three different finite element models of the head, constructed from segmented MR images of an adult male subject. The complexity of the models varied from 9 to 11 tissue types. The lead fields due to dipolar sources in the motor cortex were computed for all three models. The inverse source localizations were performed with an exhaustive search pattern in the motor cortex area. A set of 100 trial inverse runs was made. It was found that the model with most complexity performed best in localizing the sources in the motor cortex area of the brain.

Adult↗

The influence of brain tissue anisotropy on human EEG and MEG.

The influence of gray and white matter tissue anisotropy on the human electroencephalogram (EEG) and magnetoencephalogram (MEG) was examined with a high resolution finite element model of the head of an adult male subject. The conductivity tensor data for gray and white matter were estimated from magnetic resonance diffusion tensor imaging. Simulations were carried out with single dipoles or small extended sources in the cortical gray matter. The inclusion of anisotropic volume conduction in the brain was found to have a minor influence on the topology of EEG and MEG (and hence source localization). We found a major influence on the amplitude of EEG and MEG (and hence source strength estimation) due to the change in conductivity and the inclusion of anisotropy. We expect that inclusion of tissue anisotropy information will improve source estimation procedures.

Adult↗

Effect of myocardial anisotropy on the torso current flow patterns, potentials and magnetic fields.

The effects of myocardial anisotropy on the torso current flow patterns, voltage and the magnetic field were examined using an anatomically realistic torso model of an adult male subject. A finite element model of the torso was built with 19 major tissue types identified. The myocardial fibre orientation in the heart wall was included with a voxel resolution of 0.078 x 0.078 x 0.3 cm. The fibre orientations from the canine heart which are available in the literature were mapped to our adult male subject's human heart using deformable mapping techniques. The current and potential distribution in the whole torso were computed using an idealized dipolar source of +/-1.0 V in the middle of the septum of the heart wall as a boundary condition. An adaptive finite element solver was used. Two cases were studied. In one case the myocardium was isotropic and in the other it was anisotropic. It was found that the current density distribution shows a very noticeable difference between the isotropic and anisotropic myocardium. The resultant magnetic field in front of the torso was computed using the Biot-Savart law. It was found that the magnetic field profile was slightly affected by the myocardial anisotropy. The potential on the torso surface also shows noticeable changes due to the myocardial anisotropy.

Abdomen↗

Cardiac biomagnetic source estimation with a heart-torso model and a trained neural network.

The intensity of the cardiac sources for normal adult subjects was estimated from given magnetic field profiles with a trained neural network based on the relationship of the electrical activity of the heart to the cardiac magnetic fields. The input for training the neural network consisted of the magnetic field profiles above the torso during the heartbeat. The outputs were the dipole intensities which produced those magnetic field profiles. A back propagating algorithm with bias and momentum was utilized for training. The measured and simulated torso magnetic field profiles and magnetocardiograms were used for training the neural network. Estimation of the dipole intensities was performed for unknown magnetic field profiles with the trained neural network. The estimated cardiac dipole intensities were reasonably close to the true dipole intensities. These results show the feasibility of the estimation of cardiac dipole intensities with a trained neural network under a very restricted forward model of the cardiac magnetic fields. Generalization of the results to cover a large population base could be difficult because the activation isochrones are different from subject to subject.

Adult↗

MCG simulations of myocardial infarctions with a realistic heart-torso model.

Data from simulations of the anterior myocardial infarction (AMI) and inferior myocardial infarction (IMI) are presented. One infarct located in the anterior section of the left ventricle and a second one in the inferior wall of the left ventricle were modeled. A high-resolution finite element model of a heart and torso was used in this study. Differences in the normal and infarcted fields were computed. Our data suggest that the infarcted region contribution to the total magnetic field can be accounted for by an equivalent current dipole. It might also be possible to detect an infarct from these difference fields constructed for different cases of myocardial infarction. More simulations are needed to determine the relations between infarct sizes and locations and magnetic fields. These relations might then be used to detect various cases of myocardial infarction.

Biophysical Phenomena↗

MCG simulations with a realistic heart-torso model.

Magnetocardiograms (MCG's) simulated with a high-resolution heart-torso model of an adult subject were compared with measured MCG's acquired from the same individual. An exact match of the measured and simulated MCG's was not found due to the uncertainties in tissue conductivities and cardiac source positions. However, general features of the measured MCG's were reasonably represented by the simulated data for most, but not all of the channels. This suggests that the model accounts for the most important mechanisms underlying the genesis of MCG's and may be useful for cardiac magnetic field modeling under normal and diseased states. MCG's were simulated with a realistic finite-element heart-torso model constructed from segmented magnetic resonance images with 19 different tissue types identified. A finite-element model was developed from the segmented images. The model consists of 2.51 million brick-shaped elements and 2.58 million nodes, and has a voxel resolution of 1.56 x 1.56 x 3 mm. Current distributions inside the torso and the magnetic fields and MCG's at the gradiometer coil locations were computed. MCG's were measured with a Philips twin Dewar first-order gradiometer SQUID-system consisting of 31 channels in one tank and 19 channels in the other.

Adult↗

Combination of capillary electrophoresis and matrix-assisted laser desorption ionization mass spectrometry for glycosylation analysis of a human monoclonal anti-Rhesus(D) antibody.

Characterization of a human anti-Rhesus(D) monoclonal antibody, developed for the treatment of Rh(D) haemolytic disease of the newborn, was performed. Capillary electrophoresis (CE) has been employed for peptide mapping of the IgG heavy chain and glycopeptide identification. The combination of the high resolution and low solvent consumption of CE and the ultrasensitive detection and precise identification properties of mass spectrometry led to a complete glycosylation analysis of the protein. Glycopeptides were easily isolated from a single injection in a 100 microns i.d. capillary of the preparative CE system and collected for molecular mass determination using matrix-assisted laser desorption ionization mass spectrometry (MALDI-MS). The off-line CE-MS characterization revealed the presence of different oligosaccharides linked to the unique N297-S-T glycosylation site of the IgG heavy chain. The differences between calculated and experimental masses of the glycopeptides suggested the presence of a fucosylated biantennary structure containing one or two galactose units as major oligosaccharide, together with similar species bearing a bisecting N-acetylglucosamine. CE conditions were optimized to allow the MS identification of sialylated forms.

Antibodies, Monoclonal↗

Influence of tissue resistivities on neuromagnetic fields and electric potentials studied with a finite element model of the head.

Modeling in magnetoencephalography (MEG) and electroencephalography (EEG) requires knowledge of the in vivo tissue resistivities of the head. The aim of this paper is to examine the influence of tissue resistivity changes on the neuromagnetic field and the electric scalp potential. A high-resolution finite element method (FEM) model (452,162 elements, 2-mm resolution) of the human head with 13 different tissue types is employed for this purpose. Our main finding was that the magnetic fields are sensitive to changes in the tissue resistivity in the vicinity of the source. In comparison, the electric surface potentials are sensitive to changes in the tissue resistivity in the vicinity of the source and in the vicinity of the position of the electrodes. The magnitude (strength) of magnetic fields and electric surface potentials is strongly influenced by tissue resistivity changes, while the topography is not as strongly influenced. Therefore, an accurate modeling of magnetic field and electric potential strength requires accurate knowledge of tissue resistivities, while for source localization procedures this knowledge might not be a necessity.

Adipose Tissue↗

Effects of tissue conductivity variations on the cardiac magnetic fields simulated with a realistic heart-torso model.

Cardiac magnetic fields with varying tissue conductivities are simulated. A high-resolution finite-element torso model composed of 19 tissue types and with a voxel resolution of 1.5 mm x 1.5 mm x 3 mm is used. It has a detailed description of tissue geometries and therefore is well suited for analysing the effects of tissue conductivities on the cardiac magnetic fields. The computed results show the greatest sensitivity of the magnetic fields to the changes in the conductivity of blood and myocardium, and less significant sensitivity to the conductivity of the lungs, muscle, fat and other tissues. These results are relevant to future modelling of magnetocardiograms and solving the inverse problem. They also emphasize the importance of careful modelling of the blood and heart regions, and suggest that less attention needs to be directed to bone or fat tissue.

Biophysical Phenomena↗

On the contribution of volume currents to the total magnetic field resulting from the heart excitation process: a simulation study.

Data from a simulation study of volume current contribution to the total magnetic field produced in the heart excitation process is presented. Contributions from different tissue types are analyzed and effects of torso size are studied. A high resolution finite element model of an adult male torso composed of 19 tissue types is used. It has detailed description of tissue geometries and therefore is well suited for analyzing the contribution of the primary and secondary currents to the magnetic field. The computed results show major contribution of volume currents from blood, myocardium, and lungs and less significant contribution from liver, muscle, and other tissues. The contribution to the volume currents from the blood in the ventricles was highest. These simulations suggest that contribution to the total magnetic field due to volume currents flowing in tissues other than blood could be accounted for by simply multiplying the total field values by a constant. Values of these multipliers would be based on the tissue type and time in the excitation cycle. Effects of torso size on the computed magnetic fields are also evaluated. Our data shows that a torso extending approximately 3 cm above and below the heart produces field patterns similar to a larger torso model extending from top of guts to the bottom of neck. Thus a shorter torso model would be sufficient for cardiac magnetic field analysis. These results are of interest for future modeling of magnetocardiograms and solving the inverse problem.

Adult↗

Characterization of a recombinant antihaemophilia-A factor (factor VIII-delta II) by matrix-assisted laser desorption/ionization mass spectrometry.

Factor VIII-delta II is a genetically engineered deletion variant of factor VIII, expressed by recombinant Chinese hamster ovary cells. This 1436-residues-long protein has a molecular mass, calculated from its sequence, of 164,954 Da and exhibits seven potential glycosylation sites. The glycoprotein, secreted as a single polypeptide chain, can be cleaved after Arg740 to generate a heavy-light chain complex of 90-80 kDa as revealed by sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) analysis. Due to its high mass range and excellent sensitivity, matrix-assisted laser desorption/ionization-mass spectrometry (MALDI-MS) has been chosen to play a key role in the precise determination of the molecular masses of recombinant factor VIII and the localization of the post-translational modifications within the protein. Native factor VIII-delta II displays a molecular mass of 178 kDa. The masses measured by MALDI for the heavy and light chains are respectively 89,900 Da and 87,100 Da. These mass values, found reproducible from batch to batch, are used to characterize factor VIII-delta II during the course of preclinical studies. The difference from the theoretical molecular molecular masses and the observation of broad molecular peaks suggest that recombinant FVIII-delta II has been effectively glycosylated by the host cell on both heavy and light chains. Similarly to plasma-derived factor VIII, the recombinant protein is proteolyzed by thrombin to generate the A1/A2/A3-C1-C2 trimer that is the active form of factor VIII in the coagulation pathway. MALDI-MS analysis of activated factor VIII-delta II suggested the presence of N-linked oligosaccharides in the proteolyzed light chain (A3-C1-C2 of 77,750 Da) and in the A1 domain (46,400 Da) of the heavy chain. By contrast, the similarity between the experimental and theoretical masses of the A2 domain indicated that its single potential glycosylation site has not been utilized.

Enzyme Activation↗

Simulation studies of biomagnetic computed tomography.

The reconstruction of planar and three-dimensional current distributions from measured biomagnetic signals is a new field of research, known as biomagnetic computed tomography. This noninvasive imaging technique promises to provide precise, millimeter-sized resolution images of the electrical currents in tissues or organs. We performed simulation studies on phantom models of electrical sources. As a first step towards the development of an imaging algorithm, we addressed a simplified problem to identify the shape and direction of current flow in a planar surface. The problem was formulated by identifying a space in which the image was to be reconstructed. The space was segmented into a grid. Each grid space represented a current element. The magnetic field at a sampling point due to the current elements was computed using the Biot-Savart law. Since there were many more current elements than sample points, the problem was undetermined and had an uncountable number of solutions. The projection theorem was used to define an analytic solution for the magnitude and orientation of the current elements in the grid space. The solution required the inversion of large matrices in double precision. Such arrays were preprocessed on a mainframe computer, which permitted them to be rendered on any workstation. The accuracy of the image was determined by comparing it with the known location of the sources. Our results show that shape of the filamentary current flow can be imaged with our techniques. The resolution of images based on the sampling of the field, number of voxels in the reconstruction space, and noise is also analyzed.

Computer Simulation↗

Resolution enhancement of biomagnetic images using the method of alternating protections.

Resolution of biomagnetic images using the technique of the alternating projections is proposed. Our image reconstruction procedure is divided in two steps. First, the biomagnetic inverse problem is solved by use of the projection theorem to reconstruct an initial image of the current distribution from a given magnetic field profile. Although the current distribution thus obtained has poor resolution, it can resemble the original shape of the current distribution. The second step improves the resolution of the reconstructed image by using the method of alternating projections. The procedure assumes that images can be represented by line like elements and involves finding the line like elements based on the initial image and projecting back onto the original solution space. Simulation studies were performed on a set of parallel conductors and a shape of the conductors in the form of letters, UWB@. All conductors were of line like thickness. Restored images closely resemble the original shape of the conductors.

Humans↗

[The detection of thromboembolism in orthopedic traumatology: the value and limitations of D-dimer determination by the latex method].

We studied the usefulness of plasma D-dimer determination by a latex agglutination test used as a deep venous thrombosis (DVT) detection method in patients undergoing recent orthopaedic or traumatologic surgery. Asymptomatic patients with a level of D-dimer up to 1.5 micrograms/ml suffered phlebographic venous thrombosis in 49.3% of the cases. Because a predictive value of negative test of 0.77 the latex assay cannot be recommended for screening in symptomatic DVT. However, post operative measurement of cross linked fibrin derivatives in plasma may play a role in the selection of asymptomatic patients for venography.

Biomarkers↗

Preliminary report: modification of cardiac contraction rate by pulsed magnetic fields.

Isolated rat hearts and excised canine cardiac tissues were subjected to pulsed magnetic fields. The fields excited in coils by tandem pairings of sinusoidal pulses were presented at various inter-pair delays and repetition rates. The waveform of the magnetic field was a single or multiple sinusoid followed after a variable delay by another single or multiple sinusoid. Small but reliable increases in the beating rate of rat heart were observed. Similar increases occurred in contraction rates of canine tissues. Both preparations exhibited a contraction-rate dependency on the repetition rate of the paired magnetic pulses: 4.5-6 rep/s for canine tissue, and 20-25 and 40-55 reps/s for rat heart. Flux-density thresholds for both preparations approximated 10 mT (100 gauss) rms.

Animals↗

Low-level, magnetic-field-induced growth modification of Bacillus subtilis.

Experimental studies showed an increase in the growth of Bacillus subtilis mutant strain FJ7 above controls by exposing the bacterial culture to 800-Hz or 1-KHz magnetic fields with a 2-s-on/2-s-off period. The magnetic field strength was between 0.8 and 2.5 mT. Light microscopy and scanning electron microscopy demonstrated the morphology of controls to grow in a macrofiber of right-handed helix formation. In contrast, the field-exposed group showed little to no cohesion; the cells appeared to be homogeneously distributed throughout the sample. These results suggest that growth patterns of Bacillus subtilis can be altered as a result of magnetic-field-induced effects.

Bacillus subtilis↗