5 recordsLinked to original sources

Multi-isocenter stereotactic radiotherapy: implications for target dose distributions of systematic and random localization errors.

PURPOSE: This investigation examined the effect of alignment and localization errors on dose distributions in stereotactic radiotherapy (SRT) with arced circular fields. In particular, it was desired to determine the effect of systematic and random localization errors on multi-isocenter treatments. METHODS AND MATERIALS: A research version of the FastPlan system from Surgical Navigation Technologies was used to generate a series of SRT plans of varying complexity. These plans were used to examine the influence of random setup errors by recalculating dose distributions with successive setup errors convolved into the off-axis ratio data tables used in the dose calculation. The influence of systematic errors was investigated by displacing isocenters from their planned positions. RESULTS: For single-isocenter plans, it is found that the influences of setup error are strongly dependent on the size of the target volume, with minimum doses decreasing most significantly with increasing random and systematic alignment error. For multi-isocenter plans, similar variations in target dose are encountered, with this result benefiting from the conventional method of prescribing to a lower isodose value for multi-isocenter treatments relative to single-isocenter treatments. CONCLUSIONS: It is recommended that the systematic errors associated with target localization in SRT be tracked via a thorough quality assurance program, and that random setup errors be minimized by use of a sufficiently robust relocation system. These errors should also be accounted for by incorporating corrections into the treatment planning algorithm or, alternatively, by inclusion of sufficient margins in target definition.

Algorithms↗

System validation and work practice efficiency gains of a new localization method for stereotactic radiotherapy.

The increased procedural demands of stereotactic localization techniques when compared with conventional treatment practices reduces machine efficiency, an outcome likely to be greatly magnified by the introduction of fractionation to stereotactic techniques. Currently in Australia and New Zealand there are no guidelines for the definition of efficiency. We sought to devise a system to simultaneously validate the accuracy and efficiency of the technique. The frameless relocation methods employed in the Medtronic Sofamor Danek (MSD) stereotactic radiotherapy (SRT) system were studied in the clinical setting. Accuracy has been determined according to the accumulation of errors throughout the planning and treatment process. The clinical demands of the system (staffing and resources) were analysed relative to conventional treatment approaches. Timing studies indicate a mean time of 19.7 min for treatment of a daily SRT fraction (4-5 arcs, single isocentre). Cost and staffing requirements are similar to those for conventional radiotherapy. It is concluded that with the system used, SRT is efficient for routine clinical implementation, with the level of efficiency increasing with increasing patient numbers. It is recommended that a common acceptance standard be developed to allow cross-institutional comparison of the clinical efficiency of new treatment techniques.

Brain Neoplasms↗

Implementation of a stereotactic radiotherapy system.

The tests carried out on a recently-installed stereotactic radiotherapy system capable of fully frameless stereotaxy are outlined. The two principle investigations carried out on the planning system were a dosimetry test, and a test to verify the accuracy of localisation from CT examination through to patient treatment. The method employed in frameless relocation for fractionated stereotactic radiotherapy--position detection using stereoscopic infra-red cameras and a set of fiducials attached to a bite-block--was tested for reproducibility. The results of these tests suggest a mean accuracy in treatment localisation of 1.23 mm (maximum 2.72 mm) for single fraction techniques, and 1.77 mm (maximum 4.53 mm) for treatments involving repeated (frameless) localisation. The implications of these accuracies for treatment with single, multiple-fraction and multi-isocentre techniques are discussed.

Brain Diseases↗

Endoluminal brachytherapy for recurrent laryngeal carcinoma.

Early-stage squamous cell carcinoma of the larynx is usually treated with local field radiotherapy. Surgery is used for salvage following recurrence. Further recurrences present a more difficult therapeutic problem which requires individualized management. The aims of local control, survival, maintenance of function and minimizing side effects all need to be balanced according to the site and extent of disease. The present case study looks at the management of a 54-year-old man with multiple recurrences from a squamous cell carcinoma of the larynx. It describes a technique of endoluminal brachytherapy using an iridium-192 wire spiralled around the outer part of a tracheostomy tube that achieves good local control while enabling self-insertion and self-cleaning during the procedure. The dose given was 2500 cGy at 5 mm over 25.2 h and was achieved with minimal early or delayed side effects. The patient had no further symptoms relating to the stomal recurrence until his death from metastatic disease 6 months later.

Brachytherapy↗

Cancer in neck nodes with unknown primary site: role of mucosal radiotherapy.

Sixty-nine patients with metastatic squamous cell carcinoma in neck nodes with an unknown primary lesion were treated with curative intent between October 1964 and December 1986. Sixty-five patients received radiotherapy to the neck and at least part of the mucosa of the head and neck, whereas 4 patients received treatment to the neck only. Mucosal doses were approximately 5,000 cGy-6,000 cGy at 170 cGy-180 cGy per fraction. Eight patients (12%) subsequently developed mucosal site failures, a figure that did not differ significantly from the incidence of a second metachronous head and neck cancer following definitive irradiation in a series of 393 patients with lesions of the supraglottic larynx, pharyngeal wall, pyriform sinus, or tonsillar area. This suggests that radiotherapy was highly effective in preventing the appearance of cancer at the unknown primary site from which the neck metastasis arose. Absolute and cause-specific 5-year survival rates were 48% and 66%, respectively.